-Dell OPNFV Testlab\r
-==================================================\r
-\r
-Overview\r
-------------------\r
-\r
-Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project\r
-\r
-\r
-The Dell Testlab consists of 2 PODs\r
- * POD1 for Fuel\r
- * POD2 for Foreman\r
-\r
-.. image:: images/Dell_Overview.jpg\r
- :height: 553\r
- :width: 449\r
- :alt: Dell Testlab Overiew\r
- :align: left\r
-\r
-Each of the 2 PODs consists of 6 servers that consist of\r
- * 1 Jump Server\r
- * 3 Servers for Control Nodes\r
- * 2 Servers for Compute Nodes\r
-\r
-\r
-\r
-Hardware details\r
------------------\r
-\r
-All the servers within the two PODs reside within a single Dell PowerEdge 620 chassis and have the following specifications:\r
-\r
-\r
-\r
-**POD1-Fuel**\r
-\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Hostname | Model | Memory | Storage | Processor | Socket |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Fuel Jump Server | Dell PowerEdge M620 | 64 GB | 1200GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node2 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node3 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node4 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node5 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node6 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-\r
-\r
-\r
-\r
-**POD2-Foreman**\r
-\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Hostname | Model | Memory | Storage | Processor | Socket |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Foreman Jump Server | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node7 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node8 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node9 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node11 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-| Node12 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
-+---------------------+----------------------+----------------+--------------+---------------------+------------+\r
-\r
-\r
-\r
-\r
-\r
-Software\r
----------\r
-\r
-The Jump servers in the Testlab are pre-provisioned with the following softwares:\r
-\r
- * Fuel-Jump Server:\r
-\r
- 1. OS: Ubuntu 14.04\r
-\r
-\r
- * Foreman-Jump Server:\r
-\r
- 1. OS: CentOS7\r
-\r
-\r
-\r
-\r
-\r
-Networks\r
-----------\r
-\r
-\r
-\r
-**POD1-Fuel**\r
-\r
-.. image:: images/Dell_POD1.jpg\r
- :height: 647\r
- :width: 821\r
- :alt: POD1-Fuel Overview\r
- :align: left\r
-\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Hostname | NIC Model | Ports|MAC | BW | Roles |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-\r
-\r
-\r
-**POD2-Foreman**\r
-\r
-.. image:: images/Dell_POD2.jpg\r
- :height: 721\r
- :width: 785\r
- :alt: POD2-Foreman Overview\r
- :align: left\r
-\r
-\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Hostname | NIC Model | Ports|MAC | BW | Roles |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:1D | 10G | Foreman Admin |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B5:20 | 10G | Foreman Private/ Storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:21 | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B5:23 | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:CF | 10G | Foreman Admin |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B4:D2 | 10G | Foreman Private/ Storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:D3 | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B4:D5 | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:D7 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:DA | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:DC | 10G | Foreman Admin |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B4:DF | 10G | Foreman Private/ Storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:E0 | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B4:E2 | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:E4 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:E7 | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:E9 | 10G | Foreman Admin |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B4:EC | 10G | Foreman Private/ Storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:ED | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B4:EF | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:F1 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:F3 | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:03 | 10G | Foreman Admin |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B5:06 | 10G | Foreman Private/ Storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:07 | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B5:09 | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B5:0B | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B5:0D | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:10 | 10G | Foreman Admin |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | em2 | A4:1F:72:11:B5:13 | 10G | Foreman Private/ Storage |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:14 | 10G | Public |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p3p2 | A4:1F:72:11:B5:16 | 10G | Unused |\r
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |\r
-| | +------+-------------------+-------+----------------------------------+\r
-| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |\r
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
-\r
-\r
-\r
-\r
-\r
-\r
-**Subnet allocations**\r
-\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-| Network name | Address | Mask | Gateway | VLAN id |\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-| Fuel Admin | 10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged |\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-| Fuel Mangement | 192.168.0.0 | 255.255.255.0 | 192.168.0.1 | 101 |\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-| Fuel Storage | 192.168.1.0 | 255.255.255.0 | 192.168.1.1 | 102 |\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-| Fuel Public | 172.18.0.64 | 255.255.255.192 | 172.18.0.65 | Untagged |\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged |\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged |\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-| Foreman Public | 172.18.0.0 | 255.255.255.192 | 172.18.0.1 | Untagged |\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-| Lights Out | 172.18.0.128 | 255.255.255.128 | 172.18.0.129 | Untagged |\r
-+-------------------+----------------+-------------------+---------------+----------+\r
-\r
-\r
-**Lights out Network**\r
-\r
-**POD1**\r
-\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Hostname | Lights-out address | MAC | Username | Password |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Fuel-Jump | 172.18.1.131 | A4:1F:72:11:B4:80| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node2 | 172.18.1.132 | A4:1F:72:11:B4:8D| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node3 | 172.18.1.133 | A4:1F:72:11:B4:9A| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node4 | 172.18.1.134 | A4:1F:72:11:B4:A7| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node5 | 172.18.1.135 | A4:1F:72:11:B4:B4| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node6 | 172.18.1.136 | A4:1F:72:11:B4:C1| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-\r
-**POD2**\r
-\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Hostname | Lights-out address | MAC | Username | Password |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Foreman-Jump | 172.18.1.143 | A4:1F:72:11:B5:1C| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node7 | 172.18.1.137 | A4:1F:72:11:B4:CE| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node8 | 172.18.1.138 | A4:1F:72:11:B4:DB| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node9 | 172.18.1.139 | A4:1F:72:11:B4:E8| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node11 | 172.18.1.141 | A4:1F:72:11:B5:02| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-| Node12 | 172.18.1.142 | A4:1F:72:11:B5:0F| root | calvin |\r
-+----------------+-------------------------------+------------------+---------------------+---------------------+\r
-\r
-\r
-\r
-\r
-\r
-\r
-Remote access infrastructure\r
------------------------------\r
-\r
-The Dell OPNFV testlab is free to use for the OPNFV community.\r
-\r
-A VPN is used to provide access to the Dell Testlab.\r
-\r
-To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:\r
- * Name\r
- * Email\r
- * Designation\r
- * Organization\r
- * Purpose of using the lab\r
-\r
- Processing the request can take 2-3 business days.\r
-\r
-*Accessing the Teslab*\r
------------------------\r
-\r
-* POD1 JumpServer\r
-\r
- IP: 172.18.0.67\r
-\r
- User: opnfv\r
-\r
- Passwd: d3ll1234\r
-\r
-\r
-\r
-* POD2 JumpServer\r
-\r
- IP: 172.18.0.11\r
-\r
- User: opnfv\r
-\r
- Passwd: d3ll1234\r
-\r
+Dell OPNFV Testlab
+==================================================
+
+Overview
+------------------
+
+Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers
+for the use of OPNFV community as part of the OPNFV Pharos Project
+
+
+The Dell Testlab consists of 2 PODs
+ * POD1 for Fuel
+ * POD2 for Foreman
+
+.. image:: images/Dell_Overview.jpg
+ :height: 553
+ :width: 449
+ :alt: Dell Testlab Overiew
+ :align: left
+
+Each of the 2 PODs consists of 6 servers that consist of
+ * 1 Jump Server
+ * 3 Servers for Control Nodes
+ * 2 Servers for Compute Nodes
+
+
+
+Hardware details
+-----------------
+
+All the servers within the two PODs reside within a single Dell PowerEdge 620 chassis and have the
+following specifications:
+
+POD1-Fuel
+^^^^^^^^^
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Fuel Jump Server | Dell PowerEdge M620 | 64 GB | 1200GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node2 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node3 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node4 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node5 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node6 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+POD2-Foreman
+^^^^^^^^^^^^
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Foreman Jump Server | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node7 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node8 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node9 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node11 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node12 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+Software
+---------
+
+The Jump servers in the Testlab are pre-provisioned with the following softwares:
+
+ * Fuel-Jump Server:
+
+ 1. OS: Ubuntu 14.04
+
+
+ * Foreman-Jump Server:
+
+ 1. OS: CentOS7
+
+Networks
+----------
+
+POD1-Fuel
+^^^^^^^^^
+.. image:: images/Dell_POD1.jpg
+ :height: 647
+ :width: 821
+ :alt: POD1-Fuel Overview
+ :align: left
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+
+
+POD2-Foreman
+^^^^^^^^^^^^
+
+.. image:: images/Dell_POD2.jpg
+ :height: 721
+ :width: 785
+ :alt: POD2-Foreman Overview
+ :align: left
+
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:1D | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:20 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:21 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:23 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:CF | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:D2 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:D3 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:D5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:D7 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:DA | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:DC | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:DF | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:E0 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:E2 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:E4 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:E7 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:E9 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:EC | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:ED | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:EF | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:F1 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:F3 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:03 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:06 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:07 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:09 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B5:0B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B5:0D | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:10 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:13 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:14 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:16 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+Subnet allocations
+^^^^^^^^^^^^^^^^^^
+
++-------------------+----------------+-------------------+---------------+----------+
+| Network name | Address | Mask | Gateway | VLAN id |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Admin | 10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Mangement | 192.168.0.0 | 255.255.255.0 | 192.168.0.1 | 101 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Storage | 192.168.1.0 | 255.255.255.0 | 192.168.1.1 | 102 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Public | 172.18.0.64 | 255.255.255.192 | 172.18.0.65 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Public | 172.18.0.0 | 255.255.255.192 | 172.18.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Lights Out | 172.18.0.128 | 255.255.255.128 | 172.18.0.129 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+
+
+Lights out Network
+^^^^^^^^^^^^^^^^^^
+
+**POD1**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Fuel-Jump | 172.18.1.131 | A4:1F:72:11:B4:80| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node2 | 172.18.1.132 | A4:1F:72:11:B4:8D| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node3 | 172.18.1.133 | A4:1F:72:11:B4:9A| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node4 | 172.18.1.134 | A4:1F:72:11:B4:A7| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node5 | 172.18.1.135 | A4:1F:72:11:B4:B4| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node6 | 172.18.1.136 | A4:1F:72:11:B4:C1| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+**POD2**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Foreman-Jump | 172.18.1.143 | A4:1F:72:11:B5:1C| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node7 | 172.18.1.137 | A4:1F:72:11:B4:CE| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node8 | 172.18.1.138 | A4:1F:72:11:B4:DB| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node9 | 172.18.1.139 | A4:1F:72:11:B4:E8| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node11 | 172.18.1.141 | A4:1F:72:11:B5:02| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node12 | 172.18.1.142 | A4:1F:72:11:B5:0F| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+
+Remote access infrastructure
+-----------------------------
+
+The Dell OPNFV testlab is free to use for the OPNFV community.
+
+A VPN is used to provide access to the Dell Testlab.
+
+To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:
+ * Name
+ * Email
+ * Designation
+ * Organization
+ * Purpose of using the lab
+
+Processing the request can take 2-3 business days.
+
+*Accessing the Teslab*
+----------------------
+
+POD1 JumpServer
+^^^^^^^^^^^^^^^
+
+ IP: 172.18.0.67
+ User: opnfv
+ Passwd: d3ll1234
+
+
+POD2 JumpServer
+^^^^^^^^^^^^^^^
+ IP: 172.18.0.11
+ User: opnfv
+ Passwd: d3ll1234
+