c0c4750610d5bae5ab9c542f2e40d91f0072869e
[pharos.git] / docs / labs / Dell.rst
1 Dell OPNFV Testlab\r
2 ==================================================\r
3 \r
4 Overview\r
5 ------------------\r
6 \r
7 Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project\r
8 \r
9 \r
10 The Dell Testlab consists of 2 PODs\r
11     * POD1 for Fuel\r
12     * POD2 for Foreman\r
13 \r
14 .. image:: images/Dell_Overview.jpg\r
15    :height: 553\r
16    :width: 449\r
17    :alt: Dell Testlab Overiew\r
18    :align: left\r
19 \r
20 Each of the 2 PODs consists of 6 servers that consist of\r
21     * 1 Jump Server\r
22     * 3 Servers for Control Nodes\r
23     * 2 Servers for Compute Nodes\r
24 \r
25 \r
26 \r
27 Hardware details\r
28 -----------------\r
29 \r
30 All the servers within the two PODs reside within a single Dell PowerEdge 620 chassis and have the following specifications:\r
31 \r
32 \r
33 \r
34 **POD1-Fuel**\r
35 \r
36 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
37 | Hostname            |  Model               | Memory         | Storage      | Processor           | Socket     |\r
38 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
39 | Fuel Jump Server    |  Dell PowerEdge M620 | 64 GB          | 1200GB HDD   | Intel  Xeon E5-2640 |   2        |\r
40 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
41 | Node2               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |\r
42 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
43 | Node3               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |\r
44 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
45 | Node4               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |\r
46 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
47 | Node5               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |\r
48 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
49 | Node6               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |\r
50 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
51 \r
52 \r
53 \r
54 \r
55 **POD2-Foreman**\r
56 \r
57 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
58 | Hostname            |  Model               |    Memory      | Storage      | Processor           | Socket     |\r
59 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
60 | Foreman Jump Server |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |\r
61 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
62 | Node7               |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |\r
63 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
64 | Node8               |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |\r
65 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
66 | Node9               |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |\r
67 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
68 | Node11              |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |\r
69 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
70 | Node12              |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |\r
71 +---------------------+----------------------+----------------+--------------+---------------------+------------+\r
72 \r
73 \r
74 \r
75 \r
76 \r
77 Software\r
78 ---------\r
79 \r
80 The Jump servers in the Testlab are pre-provisioned with the following softwares:\r
81 \r
82  * Fuel-Jump Server:\r
83 \r
84  1. OS: Ubuntu 14.04\r
85 \r
86 \r
87  * Foreman-Jump Server:\r
88 \r
89  1. OS: CentOS7\r
90 \r
91 \r
92 \r
93 \r
94 \r
95 Networks\r
96 ----------\r
97 \r
98 \r
99 \r
100 **POD1-Fuel**\r
101 \r
102 .. image:: images/Dell_POD1.jpg\r
103    :height: 647\r
104    :width: 821\r
105    :alt: POD1-Fuel Overview\r
106    :align: left\r
107 \r
108 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
109 | Hostname            |  NIC Model                                   | Ports|MAC                | BW    | Roles                            |\r
110 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
111 | Fuel Jump           |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:81 | 10G   | Unused                           |\r
112 |                     |                                              +------+-------------------+-------+----------------------------------+\r
113 |                     |                                              | em2  | A4:1F:72:11:B4:84 | 10G   | Unused                           |\r
114 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
115 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:85 | 10G   | Public                           |\r
116 |                     |                                              +------+-------------------+-------+----------------------------------+\r
117 |                     |                                              | p3p2 | A4:1F:72:11:B4:87 | 10G   | Fuel Admin/mgmt/pvt/ storage     |\r
118 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
119 |                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:89 | 10G   | Unused                           |\r
120 |                     |                                              +------+-------------------+-------+----------------------------------+\r
121 |                     |                                              | p1p2 | A4:1F:72:11:B4:8B | 10G   | Unused                           |\r
122 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
123 | Node2               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:8E | 10G   | Unused                           |\r
124 |                     |                                              +------+-------------------+-------+----------------------------------+\r
125 |                     |                                              | em2  | A4:1F:72:11:B4:91 | 10G   | Unused                           |\r
126 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
127 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:92 | 10G   | Public                           |\r
128 |                     |                                              +------+-------------------+-------+----------------------------------+\r
129 |                     |                                              | p3p2 | A4:1F:72:11:B4:94 | 10G   | Fuel Admin/mgmt/pvt/ storage     |\r
130 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
131 |                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:96 | 10G   | Unused                           |\r
132 |                     |                                              +------+-------------------+-------+----------------------------------+\r
133 |                     |                                              | p1p2 | A4:1F:72:11:B4:98 | 10G   | Unused                           |\r
134 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
135 | Node3               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:9B | 10G   | Unused                           |\r
136 |                     |                                              +------+-------------------+-------+----------------------------------+\r
137 |                     |                                              | em2  | A4:1F:72:11:B4:9E | 10G   | Unused                           |\r
138 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
139 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:9F | 10G   | Public                           |\r
140 |                     |                                              +------+-------------------+-------+----------------------------------+\r
141 |                     |                                              | p3p2 | A4:1F:72:11:B4:A1 | 10G   | Fuel Admin/mgmt/pvt/ storage     |\r
142 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
143 |                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:A3 | 10G   | Unused                           |\r
144 |                     |                                              +------+-------------------+-------+----------------------------------+\r
145 |                     |                                              | p1p2 | A4:1F:72:11:B4:A5 | 10G   | Unused                           |\r
146 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
147 | Node4               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:A8 | 10G   | Unused                           |\r
148 |                     |                                              +------+-------------------+-------+----------------------------------+\r
149 |                     |                                              | em2  | A4:1F:72:11:B4:AB | 10G   | Unused                           |\r
150 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
151 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:AC | 10G   | Public                           |\r
152 |                     |                                              +------+-------------------+-------+----------------------------------+\r
153 |                     |                                              | p3p2 | A4:1F:72:11:B4:AE | 10G   | Fuel Admin/mgmt/pvt/ storage     |\r
154 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
155 |                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:B0 | 10G   | Unused                           |\r
156 |                     |                                              +------+-------------------+-------+----------------------------------+\r
157 |                     |                                              | p1p2 | A4:1F:72:11:B4:B1 | 10G   | Unused                           |\r
158 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
159 | Node5               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:B5 | 10G   | Unused                           |\r
160 |                     |                                              +------+-------------------+-------+----------------------------------+\r
161 |                     |                                              | em2  | A4:1F:72:11:B4:B8 | 10G   | Unused                           |\r
162 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
163 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:B9 | 10G   | Public                           |\r
164 |                     |                                              +------+-------------------+-------+----------------------------------+\r
165 |                     |                                              | p3p2 | A4:1F:72:11:B4:BB | 10G   | Fuel Admin/mgmt/pvt/ storage     |\r
166 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
167 |                     |  3, Broadcom  NetXtreme II BCM57810          | p1p1 | A4:1F:72:11:B4:BD | 10G   | Unused                           |\r
168 |                     |                                              +------+-------------------+-------+----------------------------------+\r
169 |                     |                                              | p1p2 | A4:1F:72:11:B4:C0 | 10G   | Unused                           |\r
170 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
171 | Node6               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:C2 | 10G   | Unused                           |\r
172 |                     |                                              +------+-------------------+-------+----------------------------------+\r
173 |                     |                                              | em2  | A4:1F:72:11:B4:C5 | 10G   | Unused                           |\r
174 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
175 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:C6 | 10G   | Public                           |\r
176 |                     |                                              +------+-------------------+-------+----------------------------------+\r
177 |                     |                                              | p3p2 | A4:1F:72:11:B4:C8 | 10G   | Fuel Admin/mgmt/pvt/ storage     |\r
178 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
179 |                     |  3, Broadcom  NetXtreme II BCM57810          | p1p1 | A4:1F:72:11:B4:CA | 10G   | Unused                           |\r
180 |                     |                                              +------+-------------------+-------+----------------------------------+\r
181 |                     |                                              | p1p2 | A4:1F:72:11:B4:CD | 10G   | Unused                           |\r
182 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
183 \r
184 \r
185 \r
186 **POD2-Foreman**\r
187 \r
188 .. image:: images/Dell_POD2.jpg\r
189    :height: 721\r
190    :width: 785\r
191    :alt: POD2-Foreman Overview\r
192    :align: left\r
193 \r
194 \r
195 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
196 | Hostname            |  NIC Model                                   | Ports|MAC                | BW    | Roles                            |\r
197 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
198 | Foreman Jump        |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B5:1D | 10G   | Foreman Admin                    |\r
199 |                     |                                              +------+-------------------+-------+----------------------------------+\r
200 |                     |                                              | em2  | A4:1F:72:11:B5:20 | 10G   | Foreman Private/ Storage         |\r
201 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
202 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B5:21 | 10G   | Public                           |\r
203 |                     |                                              +------+-------------------+-------+----------------------------------+\r
204 |                     |                                              | p3p2 | A4:1F:72:11:B5:23 | 10G   | Unused                           |\r
205 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
206 |                     |  3, TBD                                      | p1p1 | A4:1F:72:11:B4:89 | 10G   | Unused                           |\r
207 |                     |                                              +------+-------------------+-------+----------------------------------+\r
208 |                     |                                              | p1p2 | A4:1F:72:11:B4:8B | 10G   | Unused                           |\r
209 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
210 | Node7               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:CF | 10G   | Foreman Admin                    |\r
211 |                     |                                              +------+-------------------+-------+----------------------------------+\r
212 |                     |                                              | em2  | A4:1F:72:11:B4:D2 | 10G   | Foreman Private/ Storage         |\r
213 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
214 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:D3 | 10G   | Public                           |\r
215 |                     |                                              +------+-------------------+-------+----------------------------------+\r
216 |                     |                                              | p3p2 | A4:1F:72:11:B4:D5 | 10G   | Unused                           |\r
217 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
218 |                     |  3,  Broadcom  NetXtreme II BCM57810         | p1p1 | A4:1F:72:11:B4:D7 | 10G   | Unused                           |\r
219 |                     |                                              +------+-------------------+-------+----------------------------------+\r
220 |                     |                                              | p1p2 | A4:1F:72:11:B4:DA | 10G   | Unused                           |\r
221 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
222 | Node8               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:DC | 10G   | Foreman Admin                    |\r
223 |                     |                                              +------+-------------------+-------+----------------------------------+\r
224 |                     |                                              | em2  | A4:1F:72:11:B4:DF | 10G   | Foreman Private/ Storage         |\r
225 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
226 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:E0 | 10G   | Public                           |\r
227 |                     |                                              +------+-------------------+-------+----------------------------------+\r
228 |                     |                                              | p3p2 | A4:1F:72:11:B4:E2 | 10G   | Unused                           |\r
229 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
230 |                     |  3, Broadcom  NetXtreme II BCM57810          | p1p1 | A4:1F:72:11:B4:E4 | 10G   | Unused                           |\r
231 |                     |                                              +------+-------------------+-------+----------------------------------+\r
232 |                     |                                              | p1p2 | A4:1F:72:11:B4:E7 | 10G   | Unused                           |\r
233 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
234 | Node9               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:E9 | 10G   | Foreman Admin                    |\r
235 |                     |                                              +------+-------------------+-------+----------------------------------+\r
236 |                     |                                              | em2  | A4:1F:72:11:B4:EC | 10G   | Foreman Private/ Storage         |\r
237 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
238 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:ED | 10G   | Public                           |\r
239 |                     |                                              +------+-------------------+-------+----------------------------------+\r
240 |                     |                                              | p3p2 | A4:1F:72:11:B4:EF | 10G   | Unused                           |\r
241 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
242 |                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:F1 | 10G   | Unused                           |\r
243 |                     |                                              +------+-------------------+-------+----------------------------------+\r
244 |                     |                                              | p1p2 | A4:1F:72:11:B4:F3 | 10G   | Unused                           |\r
245 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
246 | Node11              |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B5:03 | 10G   | Foreman Admin                    |\r
247 |                     |                                              +------+-------------------+-------+----------------------------------+\r
248 |                     |                                              | em2  | A4:1F:72:11:B5:06 | 10G   | Foreman Private/ Storage         |\r
249 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
250 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B5:07 | 10G   | Public                           |\r
251 |                     |                                              +------+-------------------+-------+----------------------------------+\r
252 |                     |                                              | p3p2 | A4:1F:72:11:B5:09 | 10G   | Unused                           |\r
253 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
254 |                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B5:0B | 10G   | Unused                           |\r
255 |                     |                                              +------+-------------------+-------+----------------------------------+\r
256 |                     |                                              | p1p2 | A4:1F:72:11:B5:0D | 10G   | Unused                           |\r
257 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
258 | Node12              |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B5:10 | 10G   | Foreman Admin                    |\r
259 |                     |                                              +------+-------------------+-------+----------------------------------+\r
260 |                     |                                              | em2  | A4:1F:72:11:B5:13 | 10G   | Foreman Private/ Storage         |\r
261 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
262 |                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B5:14 | 10G   | Public                           |\r
263 |                     |                                              +------+-------------------+-------+----------------------------------+\r
264 |                     |                                              | p3p2 | A4:1F:72:11:B5:16 | 10G   | Unused                           |\r
265 |                     +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
266 |                     |  3, TBD                                      | p1p1 | A4:1F:72:11:B4:89 | 10G   | Unused                           |\r
267 |                     |                                              +------+-------------------+-------+----------------------------------+\r
268 |                     |                                              | p1p2 | A4:1F:72:11:B4:8B | 10G   | Unused                           |\r
269 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
270 \r
271 \r
272 \r
273 \r
274 \r
275 \r
276 **Subnet allocations**\r
277 \r
278 +-------------------+----------------+-------------------+---------------+----------+\r
279 | Network name      | Address        | Mask              | Gateway       | VLAN id  |\r
280 +-------------------+----------------+-------------------+---------------+----------+\r
281 | Fuel Admin        | 10.20.0.0      |  255.255.0.0      | 10.20.0.1     | Untagged |\r
282 +-------------------+----------------+-------------------+---------------+----------+\r
283 | Fuel Mangement    | 192.168.0.0    |  255.255.255.0    | 192.168.0.1   | 101      |\r
284 +-------------------+----------------+-------------------+---------------+----------+\r
285 | Fuel Storage      | 192.168.1.0    |  255.255.255.0    | 192.168.1.1   | 102      |\r
286 +-------------------+----------------+-------------------+---------------+----------+\r
287 | Fuel Public       | 172.18.0.64    |  255.255.255.192  | 172.18.0.65   | Untagged |\r
288 +-------------------+----------------+-------------------+---------------+----------+\r
289 | Foreman  Admin    | 10.4.14.0      |  255.255.255.0    | 10.4.14.100   | Untagged |\r
290 +-------------------+----------------+-------------------+---------------+----------+\r
291 | Foreman Private   | 10.4.5.0       |  255.255.255.0    | 10.4.5.1      | Untagged |\r
292 +-------------------+----------------+-------------------+---------------+----------+\r
293 | Foreman Public    | 172.18.0.0     |  255.255.255.192  | 172.18.0.1    | Untagged |\r
294 +-------------------+----------------+-------------------+---------------+----------+\r
295 | Lights Out        | 172.18.0.128   |  255.255.255.128  | 172.18.0.129  | Untagged |\r
296 +-------------------+----------------+-------------------+---------------+----------+\r
297 \r
298 \r
299 **Lights out Network**\r
300 \r
301 **POD1**\r
302 \r
303 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
304 | Hostname       | Lights-out address            | MAC              |    Username         | Password            |\r
305 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
306 | Fuel-Jump      | 172.18.1.131                  | A4:1F:72:11:B4:80|      root           |      calvin         |\r
307 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
308 | Node2          | 172.18.1.132                  | A4:1F:72:11:B4:8D|      root           |      calvin         |\r
309 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
310 | Node3          | 172.18.1.133                  | A4:1F:72:11:B4:9A|      root           |      calvin         |\r
311 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
312 | Node4          | 172.18.1.134                  | A4:1F:72:11:B4:A7|      root           |      calvin         |\r
313 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
314 | Node5          | 172.18.1.135                  | A4:1F:72:11:B4:B4|      root           |      calvin         |\r
315 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
316 | Node6          | 172.18.1.136                  | A4:1F:72:11:B4:C1|      root           |      calvin         |\r
317 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
318 \r
319 **POD2**\r
320 \r
321 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
322 | Hostname       | Lights-out address            | MAC              |    Username         | Password            |\r
323 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
324 | Foreman-Jump   | 172.18.1.143                  | A4:1F:72:11:B5:1C|      root           |      calvin         |\r
325 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
326 | Node7          | 172.18.1.137                  | A4:1F:72:11:B4:CE|      root           |      calvin         |\r
327 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
328 | Node8          | 172.18.1.138                  | A4:1F:72:11:B4:DB|      root           |      calvin         |\r
329 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
330 | Node9          | 172.18.1.139                  | A4:1F:72:11:B4:E8|      root           |      calvin         |\r
331 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
332 | Node11         | 172.18.1.141                  | A4:1F:72:11:B5:02|      root           |      calvin         |\r
333 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
334 | Node12         | 172.18.1.142                  | A4:1F:72:11:B5:0F|      root           |      calvin         |\r
335 +----------------+-------------------------------+------------------+---------------------+---------------------+\r
336 \r
337 \r
338 \r
339 \r
340 \r
341 \r
342 Remote access infrastructure\r
343 -----------------------------\r
344 \r
345 The Dell OPNFV testlab is free to use for the OPNFV community.\r
346 \r
347 A VPN is used to provide access to the Dell Testlab.\r
348 \r
349 To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:\r
350  * Name\r
351  * Email\r
352  * Designation\r
353  * Organization\r
354  * Purpose of using the lab\r
355 \r
356  Processing the request can take 2-3 business days.\r
357 \r
358 *Accessing the Teslab*\r
359 -----------------------\r
360 \r
361 * POD1 JumpServer\r
362 \r
363   IP: 172.18.0.67\r
364 \r
365   User:  opnfv\r
366 \r
367   Passwd: d3ll1234\r
368 \r
369 \r
370 \r
371 * POD2 JumpServer\r
372 \r
373   IP: 172.18.0.11\r
374 \r
375   User:  opnfv\r
376 \r
377   Passwd: d3ll1234\r
378 \r