2 ==================================================
\r
7 Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project
\r
10 The Dell Testlab consists of 2 PODs
\r
14 .. image:: images/Dell_Overview.jpg
\r
17 :alt: Dell Testlab Overiew
\r
20 Each of the 2 PODs consists of 6 servers that consist of
\r
22 * 3 Servers for Control Nodes
\r
23 * 2 Servers for Compute Nodes
\r
30 All the servers within the two PODs reside within a single Dell PowerEdge 620 chassis and have the following specifications:
\r
36 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
37 | Hostname | Model | Memory | Storage | Processor | Socket |
\r
38 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
39 | Fuel Jump Server | Dell PowerEdge M620 | 64 GB | 1200GB HDD | Intel Xeon E5-2640 | 2 |
\r
40 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
41 | Node2 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
\r
42 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
43 | Node3 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
\r
44 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
45 | Node4 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
\r
46 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
47 | Node5 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
\r
48 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
49 | Node6 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
\r
50 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
57 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
58 | Hostname | Model | Memory | Storage | Processor | Socket |
\r
59 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
60 | Foreman Jump Server | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
\r
61 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
62 | Node7 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
\r
63 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
64 | Node8 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
\r
65 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
66 | Node9 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
\r
67 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
68 | Node11 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
\r
69 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
70 | Node12 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
\r
71 +---------------------+----------------------+----------------+--------------+---------------------+------------+
\r
80 The Jump servers in the Testlab are pre-provisioned with the following softwares:
\r
87 * Foreman-Jump Server:
\r
102 .. image:: images/Dell_POD1.jpg
\r
105 :alt: POD1-Fuel Overview
\r
108 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
109 | Hostname | NIC Model | Ports|MAC | BW | Roles |
\r
110 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
111 | Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused |
\r
112 | | +------+-------------------+-------+----------------------------------+
\r
113 | | | em2 | A4:1F:72:11:B4:84 | 10G | Unused |
\r
114 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
115 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public |
\r
116 | | +------+-------------------+-------+----------------------------------+
\r
117 | | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |
\r
118 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
119 | | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
\r
120 | | +------+-------------------+-------+----------------------------------+
\r
121 | | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
\r
122 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
123 | Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused |
\r
124 | | +------+-------------------+-------+----------------------------------+
\r
125 | | | em2 | A4:1F:72:11:B4:91 | 10G | Unused |
\r
126 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
127 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public |
\r
128 | | +------+-------------------+-------+----------------------------------+
\r
129 | | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |
\r
130 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
131 | | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |
\r
132 | | +------+-------------------+-------+----------------------------------+
\r
133 | | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |
\r
134 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
135 | Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused |
\r
136 | | +------+-------------------+-------+----------------------------------+
\r
137 | | | em2 | A4:1F:72:11:B4:9E | 10G | Unused |
\r
138 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
139 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public |
\r
140 | | +------+-------------------+-------+----------------------------------+
\r
141 | | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |
\r
142 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
143 | | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |
\r
144 | | +------+-------------------+-------+----------------------------------+
\r
145 | | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |
\r
146 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
147 | Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused |
\r
148 | | +------+-------------------+-------+----------------------------------+
\r
149 | | | em2 | A4:1F:72:11:B4:AB | 10G | Unused |
\r
150 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
151 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public |
\r
152 | | +------+-------------------+-------+----------------------------------+
\r
153 | | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |
\r
154 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
155 | | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |
\r
156 | | +------+-------------------+-------+----------------------------------+
\r
157 | | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |
\r
158 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
159 | Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused |
\r
160 | | +------+-------------------+-------+----------------------------------+
\r
161 | | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused |
\r
162 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
163 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public |
\r
164 | | +------+-------------------+-------+----------------------------------+
\r
165 | | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |
\r
166 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
167 | | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |
\r
168 | | +------+-------------------+-------+----------------------------------+
\r
169 | | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |
\r
170 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
171 | Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused |
\r
172 | | +------+-------------------+-------+----------------------------------+
\r
173 | | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused |
\r
174 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
175 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public |
\r
176 | | +------+-------------------+-------+----------------------------------+
\r
177 | | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |
\r
178 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
179 | | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |
\r
180 | | +------+-------------------+-------+----------------------------------+
\r
181 | | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |
\r
182 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
188 .. image:: images/Dell_POD2.jpg
\r
191 :alt: POD2-Foreman Overview
\r
195 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
196 | Hostname | NIC Model | Ports|MAC | BW | Roles |
\r
197 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
198 | Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:1D | 10G | Foreman Admin |
\r
199 | | +------+-------------------+-------+----------------------------------+
\r
200 | | | em2 | A4:1F:72:11:B5:20 | 10G | Foreman Private/ Storage |
\r
201 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
202 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:21 | 10G | Public |
\r
203 | | +------+-------------------+-------+----------------------------------+
\r
204 | | | p3p2 | A4:1F:72:11:B5:23 | 10G | Unused |
\r
205 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
206 | | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
\r
207 | | +------+-------------------+-------+----------------------------------+
\r
208 | | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
\r
209 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
210 | Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:CF | 10G | Foreman Admin |
\r
211 | | +------+-------------------+-------+----------------------------------+
\r
212 | | | em2 | A4:1F:72:11:B4:D2 | 10G | Foreman Private/ Storage |
\r
213 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
214 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:D3 | 10G | Public |
\r
215 | | +------+-------------------+-------+----------------------------------+
\r
216 | | | p3p2 | A4:1F:72:11:B4:D5 | 10G | Unused |
\r
217 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
218 | | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:D7 | 10G | Unused |
\r
219 | | +------+-------------------+-------+----------------------------------+
\r
220 | | | p1p2 | A4:1F:72:11:B4:DA | 10G | Unused |
\r
221 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
222 | Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:DC | 10G | Foreman Admin |
\r
223 | | +------+-------------------+-------+----------------------------------+
\r
224 | | | em2 | A4:1F:72:11:B4:DF | 10G | Foreman Private/ Storage |
\r
225 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
226 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:E0 | 10G | Public |
\r
227 | | +------+-------------------+-------+----------------------------------+
\r
228 | | | p3p2 | A4:1F:72:11:B4:E2 | 10G | Unused |
\r
229 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
230 | | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:E4 | 10G | Unused |
\r
231 | | +------+-------------------+-------+----------------------------------+
\r
232 | | | p1p2 | A4:1F:72:11:B4:E7 | 10G | Unused |
\r
233 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
234 | Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:E9 | 10G | Foreman Admin |
\r
235 | | +------+-------------------+-------+----------------------------------+
\r
236 | | | em2 | A4:1F:72:11:B4:EC | 10G | Foreman Private/ Storage |
\r
237 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
238 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:ED | 10G | Public |
\r
239 | | +------+-------------------+-------+----------------------------------+
\r
240 | | | p3p2 | A4:1F:72:11:B4:EF | 10G | Unused |
\r
241 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
242 | | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:F1 | 10G | Unused |
\r
243 | | +------+-------------------+-------+----------------------------------+
\r
244 | | | p1p2 | A4:1F:72:11:B4:F3 | 10G | Unused |
\r
245 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
246 | Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:03 | 10G | Foreman Admin |
\r
247 | | +------+-------------------+-------+----------------------------------+
\r
248 | | | em2 | A4:1F:72:11:B5:06 | 10G | Foreman Private/ Storage |
\r
249 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
250 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:07 | 10G | Public |
\r
251 | | +------+-------------------+-------+----------------------------------+
\r
252 | | | p3p2 | A4:1F:72:11:B5:09 | 10G | Unused |
\r
253 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
254 | | 3, Intel 82599 | p1p1 | A4:1F:72:11:B5:0B | 10G | Unused |
\r
255 | | +------+-------------------+-------+----------------------------------+
\r
256 | | | p1p2 | A4:1F:72:11:B5:0D | 10G | Unused |
\r
257 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
258 | Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:10 | 10G | Foreman Admin |
\r
259 | | +------+-------------------+-------+----------------------------------+
\r
260 | | | em2 | A4:1F:72:11:B5:13 | 10G | Foreman Private/ Storage |
\r
261 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
262 | | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:14 | 10G | Public |
\r
263 | | +------+-------------------+-------+----------------------------------+
\r
264 | | | p3p2 | A4:1F:72:11:B5:16 | 10G | Unused |
\r
265 | +----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
266 | | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
\r
267 | | +------+-------------------+-------+----------------------------------+
\r
268 | | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
\r
269 +---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
\r
276 **Subnet allocations**
\r
278 +-------------------+----------------+-------------------+---------------+----------+
\r
279 | Network name | Address | Mask | Gateway | VLAN id |
\r
280 +-------------------+----------------+-------------------+---------------+----------+
\r
281 | Fuel Admin | 10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged |
\r
282 +-------------------+----------------+-------------------+---------------+----------+
\r
283 | Fuel Mangement | 192.168.0.0 | 255.255.255.0 | 192.168.0.1 | 101 |
\r
284 +-------------------+----------------+-------------------+---------------+----------+
\r
285 | Fuel Storage | 192.168.1.0 | 255.255.255.0 | 192.168.1.1 | 102 |
\r
286 +-------------------+----------------+-------------------+---------------+----------+
\r
287 | Fuel Public | 172.18.0.64 | 255.255.255.192 | 172.18.0.65 | Untagged |
\r
288 +-------------------+----------------+-------------------+---------------+----------+
\r
289 | Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged |
\r
290 +-------------------+----------------+-------------------+---------------+----------+
\r
291 | Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged |
\r
292 +-------------------+----------------+-------------------+---------------+----------+
\r
293 | Foreman Public | 172.18.0.0 | 255.255.255.192 | 172.18.0.1 | Untagged |
\r
294 +-------------------+----------------+-------------------+---------------+----------+
\r
295 | Lights Out | 172.18.0.128 | 255.255.255.128 | 172.18.0.129 | Untagged |
\r
296 +-------------------+----------------+-------------------+---------------+----------+
\r
299 **Lights out Network**
\r
303 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
304 | Hostname | Lights-out address | MAC | Username | Password |
\r
305 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
306 | Fuel-Jump | 172.18.1.131 | A4:1F:72:11:B4:80| root | calvin |
\r
307 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
308 | Node2 | 172.18.1.132 | A4:1F:72:11:B4:8D| root | calvin |
\r
309 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
310 | Node3 | 172.18.1.133 | A4:1F:72:11:B4:9A| root | calvin |
\r
311 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
312 | Node4 | 172.18.1.134 | A4:1F:72:11:B4:A7| root | calvin |
\r
313 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
314 | Node5 | 172.18.1.135 | A4:1F:72:11:B4:B4| root | calvin |
\r
315 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
316 | Node6 | 172.18.1.136 | A4:1F:72:11:B4:C1| root | calvin |
\r
317 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
321 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
322 | Hostname | Lights-out address | MAC | Username | Password |
\r
323 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
324 | Foreman-Jump | 172.18.1.143 | A4:1F:72:11:B5:1C| root | calvin |
\r
325 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
326 | Node7 | 172.18.1.137 | A4:1F:72:11:B4:CE| root | calvin |
\r
327 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
328 | Node8 | 172.18.1.138 | A4:1F:72:11:B4:DB| root | calvin |
\r
329 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
330 | Node9 | 172.18.1.139 | A4:1F:72:11:B4:E8| root | calvin |
\r
331 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
332 | Node11 | 172.18.1.141 | A4:1F:72:11:B5:02| root | calvin |
\r
333 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
334 | Node12 | 172.18.1.142 | A4:1F:72:11:B5:0F| root | calvin |
\r
335 +----------------+-------------------------------+------------------+---------------------+---------------------+
\r
342 Remote access infrastructure
\r
343 -----------------------------
\r
345 The Dell OPNFV testlab is free to use for the OPNFV community.
\r
347 A VPN is used to provide access to the Dell Testlab.
\r
349 To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:
\r
354 * Purpose of using the lab
\r
356 Processing the request can take 2-3 business days.
\r
358 *Accessing the Teslab*
\r
359 -----------------------
\r