1 ======================
2  Troubleshooting OSDs
3 ======================
4
5 Before troubleshooting your OSDs, check your monitors and network first. If
6 you execute ``ceph health`` or ``ceph -s`` on the command line and Ceph returns
7 a health status, it means that the monitors have a quorum.
8 If you don't have a monitor quorum or if there are errors with the monitor
9 status, `address the monitor issues first <../troubleshooting-mon>`_.
10 Check your networks to ensure they
11 are running properly, because networks may have a significant impact on OSD
12 operation and performance.
13
14
15
16 Obtaining Data About OSDs
17 =========================
18
19 A good first step in troubleshooting your OSDs is to obtain information in
20 addition to the information you collected while `monitoring your OSDs`_
21 (e.g., ``ceph osd tree``).
22
23
24 Ceph Logs
25 ---------
26
27 If you haven't changed the default path, you can find Ceph log files at
28 ``/var/log/ceph``::
29
30         ls /var/log/ceph
31
32 If you don't get enough log detail, you can change your logging level.  See
33 `Logging and Debugging`_ for details to ensure that Ceph performs adequately
34 under high logging volume.
35
36
37 Admin Socket
38 ------------
39
40 Use the admin socket tool to retrieve runtime information. For details, list
41 the sockets for your Ceph processes::
42
43         ls /var/run/ceph
44
45 Then, execute the following, replacing ``{daemon-name}`` with an actual
46 daemon (e.g., ``osd.0``)::
47
48   ceph daemon osd.0 help
49
50 Alternatively, you can specify a ``{socket-file}`` (e.g., something in ``/var/run/ceph``)::
51
52   ceph daemon {socket-file} help
53
54
55 The admin socket, among other things, allows you to:
56
57 - List your configuration at runtime
58 - Dump historic operations
59 - Dump the operation priority queue state
60 - Dump operations in flight
61 - Dump perfcounters
62
63
64 Display Freespace
65 -----------------
66
67 Filesystem issues may arise. To display your filesystem's free space, execute
68 ``df``. ::
69
70         df -h
71
72 Execute ``df --help`` for additional usage.
73
74
75 I/O Statistics
76 --------------
77
78 Use `iostat`_ to identify I/O-related issues. ::
79
80         iostat -x
81
82
83 Diagnostic Messages
84 -------------------
85
86 To retrieve diagnostic messages, use ``dmesg`` with ``less``, ``more``, ``grep``
87 or ``tail``.  For example::
88
89         dmesg | grep scsi
90
91
92 Stopping w/out Rebalancing
93 ==========================
94
95 Periodically, you may need to perform maintenance on a subset of your cluster,
96 or resolve a problem that affects a failure domain (e.g., a rack). If you do not
97 want CRUSH to automatically rebalance the cluster as you stop OSDs for
98 maintenance, set the cluster to ``noout`` first::
99
100         ceph osd set noout
101
102 Once the cluster is set to ``noout``, you can begin stopping the OSDs within the
103 failure domain that requires maintenance work. ::
104
105         stop ceph-osd id={num}
106
107 .. note:: Placement groups within the OSDs you stop will become ``degraded``
108    while you are addressing issues with within the failure domain.
109
110 Once you have completed your maintenance, restart the OSDs. ::
111
112         start ceph-osd id={num}
113
114 Finally, you must unset the cluster from ``noout``. ::
115
116         ceph osd unset noout
117
118
119
120 .. _osd-not-running:
121
122 OSD Not Running
123 ===============
124
125 Under normal circumstances, simply restarting the ``ceph-osd`` daemon will
126 allow it to rejoin the cluster and recover.
127
128 An OSD Won't Start
129 ------------------
130
131 If you start your cluster and an OSD won't start, check the following:
132
133 - **Configuration File:** If you were not able to get OSDs running from
134   a new installation, check your configuration file to ensure it conforms
135   (e.g., ``host`` not ``hostname``, etc.).
136
137 - **Check Paths:** Check the paths in your configuration, and the actual
138   paths themselves for data and journals. If you separate the OSD data from
139   the journal data and there are errors in your configuration file or in the
140   actual mounts, you may have trouble starting OSDs. If you want to store the
141   journal on a block device, you should partition your journal disk and assign
142   one partition per OSD.
143
144 - **Check Max Threadcount:** If you have a node with a lot of OSDs, you may be
145   hitting the default maximum number of threads (e.g., usually 32k), especially
146   during recovery. You can increase the number of threads using ``sysctl`` to
147   see if increasing the maximum number of threads to the maximum possible
148   number of threads allowed (i.e.,  4194303) will help. For example::
149
150         sysctl -w kernel.pid_max=4194303
151
152   If increasing the maximum thread count resolves the issue, you can make it
153   permanent by including a ``kernel.pid_max`` setting in the
154   ``/etc/sysctl.conf`` file. For example::
155
156         kernel.pid_max = 4194303
157
158 - **Kernel Version:** Identify the kernel version and distribution you
159   are using. Ceph uses some third party tools by default, which may be
160   buggy or may conflict with certain distributions and/or kernel
161   versions (e.g., Google perftools). Check the `OS recommendations`_
162   to ensure you have addressed any issues related to your kernel.
163
164 - **Segment Fault:** If there is a segment fault, turn your logging up
165   (if it is not already), and try again. If it segment faults again,
166   contact the ceph-devel email list and provide your Ceph configuration
167   file, your monitor output and the contents of your log file(s).
168
169
170
171 An OSD Failed
172 -------------
173
174 When a ``ceph-osd`` process dies, the monitor will learn about the failure
175 from surviving ``ceph-osd`` daemons and report it via the ``ceph health``
176 command::
177
178         ceph health
179         HEALTH_WARN 1/3 in osds are down
180
181 Specifically, you will get a warning whenever there are ``ceph-osd``
182 processes that are marked ``in`` and ``down``.  You can identify which
183 ``ceph-osds`` are ``down`` with::
184
185         ceph health detail
186         HEALTH_WARN 1/3 in osds are down
187         osd.0 is down since epoch 23, last address 192.168.106.220:6800/11080
188
189 If there is a disk
190 failure or other fault preventing ``ceph-osd`` from functioning or
191 restarting, an error message should be present in its log file in
192 ``/var/log/ceph``.
193
194 If the daemon stopped because of a heartbeat failure, the underlying
195 kernel file system may be unresponsive. Check ``dmesg`` output for disk
196 or other kernel errors.
197
198 If the problem is a software error (failed assertion or other
199 unexpected error), it should be reported to the `ceph-devel`_ email list.
200
201
202 No Free Drive Space
203 -------------------
204
205 Ceph prevents you from writing to a full OSD so that you don't lose data.
206 In an operational cluster, you should receive a warning when your cluster
207 is getting near its full ratio. The ``mon osd full ratio`` defaults to
208 ``0.95``, or 95% of capacity before it stops clients from writing data.
209 The ``mon osd backfillfull ratio`` defaults to ``0.90``, or 90 % of
210 capacity when it blocks backfills from starting. The
211 ``mon osd nearfull ratio`` defaults to ``0.85``, or 85% of capacity
212 when it generates a health warning.
213
214 Full cluster issues usually arise when testing how Ceph handles an OSD
215 failure on a small cluster. When one node has a high percentage of the
216 cluster's data, the cluster can easily eclipse its nearfull and full ratio
217 immediately. If you are testing how Ceph reacts to OSD failures on a small
218 cluster, you should leave ample free disk space and consider temporarily
219 lowering the ``mon osd full ratio``, ``mon osd backfillfull ratio``  and
220 ``mon osd nearfull ratio``.
221
222 Full ``ceph-osds`` will be reported by ``ceph health``::
223
224         ceph health
225         HEALTH_WARN 1 nearfull osd(s)
226
227 Or::
228
229         ceph health detail
230         HEALTH_ERR 1 full osd(s); 1 backfillfull osd(s); 1 nearfull osd(s)
231         osd.3 is full at 97%
232         osd.4 is backfill full at 91%
233         osd.2 is near full at 87%
234
235 The best way to deal with a full cluster is to add new ``ceph-osds``, allowing
236 the cluster to redistribute data to the newly available storage.
237
238 If you cannot start an OSD because it is full, you may delete some data by deleting
239 some placement group directories in the full OSD.
240
241 .. important:: If you choose to delete a placement group directory on a full OSD,
242    **DO NOT** delete the same placement group directory on another full OSD, or
243    **YOU MAY LOSE DATA**. You **MUST** maintain at least one copy of your data on
244    at least one OSD.
245
246 See `Monitor Config Reference`_ for additional details.
247
248
249 OSDs are Slow/Unresponsive
250 ==========================
251
252 A commonly recurring issue involves slow or unresponsive OSDs. Ensure that you
253 have eliminated other troubleshooting possibilities before delving into OSD
254 performance issues. For example, ensure that your network(s) is working properly
255 and your OSDs are running. Check to see if OSDs are throttling recovery traffic.
256
257 .. tip:: Newer versions of Ceph provide better recovery handling by preventing
258    recovering OSDs from using up system resources so that ``up`` and ``in``
259    OSDs are not available or are otherwise slow.
260
261
262 Networking Issues
263 -----------------
264
265 Ceph is a distributed storage system, so it  depends upon networks to peer with
266 OSDs, replicate objects, recover from faults and check heartbeats. Networking
267 issues can cause OSD latency and flapping OSDs. See `Flapping OSDs`_ for
268 details.
269
270 Ensure that Ceph processes and Ceph-dependent processes are connected and/or
271 listening. ::
272
273         netstat -a | grep ceph
274         netstat -l | grep ceph
275         sudo netstat -p | grep ceph
276
277 Check network statistics. ::
278
279         netstat -s
280
281
282 Drive Configuration
283 -------------------
284
285 A storage drive should only support one OSD. Sequential read and sequential
286 write throughput can bottleneck if other processes share the drive, including
287 journals, operating systems, monitors, other OSDs and non-Ceph processes.
288
289 Ceph acknowledges writes *after* journaling, so fast SSDs are an
290 attractive option to accelerate the response time--particularly when
291 using the ``XFS`` or ``ext4`` filesystems.  By contrast, the ``btrfs``
292 filesystem can write and journal simultaneously.  (Note, however, that
293 we recommend against using ``btrfs`` for production deployments.)
294
295 .. note:: Partitioning a drive does not change its total throughput or
296    sequential read/write limits. Running a journal in a separate partition
297    may help, but you should prefer a separate physical drive.
298
299
300 Bad Sectors / Fragmented Disk
301 -----------------------------
302
303 Check your disks for bad sectors and fragmentation. This can cause total throughput
304 to drop substantially.
305
306
307 Co-resident Monitors/OSDs
308 -------------------------
309
310 Monitors are generally light-weight processes, but they do lots of ``fsync()``,
311 which can interfere with other workloads, particularly if monitors run on the
312 same drive as your OSDs. Additionally, if you run monitors on the same host as
313 the OSDs, you may incur performance issues related to:
314
315 - Running an older kernel (pre-3.0)
316 - Running Argonaut with an old ``glibc``
317 - Running a kernel with no syncfs(2) syscall.
318
319 In these cases, multiple OSDs running on the same host can drag each other down
320 by doing lots of commits. That often leads to the bursty writes.
321
322
323 Co-resident Processes
324 ---------------------
325
326 Spinning up co-resident processes such as a cloud-based solution, virtual
327 machines and other applications that write data to Ceph while operating on the
328 same hardware as OSDs can introduce significant OSD latency. Generally, we
329 recommend optimizing a host for use with Ceph and using other hosts for other
330 processes. The practice of separating Ceph operations from other applications
331 may help improve performance and may streamline troubleshooting and maintenance.
332
333
334 Logging Levels
335 --------------
336
337 If you turned logging levels up to track an issue and then forgot to turn
338 logging levels back down, the OSD may be putting a lot of logs onto the disk. If
339 you intend to keep logging levels high, you may consider mounting a drive to the
340 default path for logging (i.e., ``/var/log/ceph/$cluster-$name.log``).
341
342
343 Recovery Throttling
344 -------------------
345
346 Depending upon your configuration, Ceph may reduce recovery rates to maintain
347 performance or it may increase recovery rates to the point that recovery
348 impacts OSD performance. Check to see if the OSD is recovering.
349
350
351 Kernel Version
352 --------------
353
354 Check the kernel version you are running. Older kernels may not receive
355 new backports that Ceph depends upon for better performance.
356
357
358 Kernel Issues with SyncFS
359 -------------------------
360
361 Try running one OSD per host to see if performance improves. Old kernels
362 might not have a recent enough version of ``glibc`` to support ``syncfs(2)``.
363
364
365 Filesystem Issues
366 -----------------
367
368 Currently, we recommend deploying clusters with XFS.
369
370 We recommend against using btrfs or ext4.  The btrfs filesystem has
371 many attractive features, but bugs in the filesystem may lead to
372 performance issues and suprious ENOSPC errors.  We do not recommend
373 ext4 because xattr size limitations break our support for long object
374 names (needed for RGW).
375
376 For more information, see `Filesystem Recommendations`_.
377
378 .. _Filesystem Recommendations: ../configuration/filesystem-recommendations
379
380
381 Insufficient RAM
382 ----------------
383
384 We recommend 1GB of RAM per OSD daemon. You may notice that during normal
385 operations, the OSD only uses a fraction of that amount (e.g., 100-200MB).
386 Unused RAM makes it tempting to use the excess RAM for co-resident applications,
387 VMs and so forth. However, when OSDs go into recovery mode, their memory
388 utilization spikes. If there is no RAM available, the OSD performance will slow
389 considerably.
390
391
392 Old Requests or Slow Requests
393 -----------------------------
394
395 If a ``ceph-osd`` daemon is slow to respond to a request, it will generate log messages
396 complaining about requests that are taking too long.  The warning threshold
397 defaults to 30 seconds, and is configurable via the ``osd op complaint time``
398 option.  When this happens, the cluster log will receive messages.
399
400 Legacy versions of Ceph complain about 'old requests`::
401
402         osd.0 192.168.106.220:6800/18813 312 : [WRN] old request osd_op(client.5099.0:790 fatty_26485_object789 [write 0~4096] 2.5e54f643) v4 received at 2012-03-06 15:42:56.054801 currently waiting for sub ops
403
404 New versions of Ceph complain about 'slow requests`::
405
406         {date} {osd.num} [WRN] 1 slow requests, 1 included below; oldest blocked for > 30.005692 secs
407         {date} {osd.num}  [WRN] slow request 30.005692 seconds old, received at {date-time}: osd_op(client.4240.0:8 benchmark_data_ceph-1_39426_object7 [write 0~4194304] 0.69848840) v4 currently waiting for subops from [610]
408
409
410 Possible causes include:
411
412 - A bad drive (check ``dmesg`` output)
413 - A bug in the kernel file system bug (check ``dmesg`` output)
414 - An overloaded cluster (check system load, iostat, etc.)
415 - A bug in the ``ceph-osd`` daemon.
416
417 Possible solutions
418
419 - Remove VMs Cloud Solutions from Ceph Hosts
420 - Upgrade Kernel
421 - Upgrade Ceph
422 - Restart OSDs
423
424 Debugging Slow Requests
425 -----------------------
426
427 If you run "ceph daemon osd.<id> dump_historic_ops" or "dump_ops_in_flight",
428 you will see a set of operations and a list of events each operation went
429 through. These are briefly described below.
430
431 Events from the Messenger layer:
432
433 - header_read: when the messenger first started reading the message off the wire
434 - throttled: when the messenger tried to acquire memory throttle space to read
435   the message into memory
436 - all_read: when the messenger finished reading the message off the wire
437 - dispatched: when the messenger gave the message to the OSD
438 - Initiated: <This is identical to header_read. The existence of both is a
439   historical oddity.
440
441 Events from the OSD as it prepares operations
442
443 - queued_for_pg: the op has been put into the queue for processing by its PG
444 - reached_pg: the PG has started doing the op
445 - waiting for \*: the op is waiting for some other work to complete before it
446   can proceed (a new OSDMap; for its object target to scrub; for the PG to
447   finish peering; all as specified in the message)
448 - started: the op has been accepted as something the OSD should actually do
449   (reasons not to do it: failed security/permission checks; out-of-date local
450   state; etc) and is now actually being performed
451 - waiting for subops from: the op has been sent to replica OSDs
452
453 Events from the FileStore
454
455 - commit_queued_for_journal_write: the op has been given to the FileStore
456 - write_thread_in_journal_buffer: the op is in the journal's buffer and waiting
457   to be persisted (as the next disk write)
458 - journaled_completion_queued: the op was journaled to disk and its callback
459   queued for invocation
460
461 Events from the OSD after stuff has been given to local disk
462
463 - op_commit: the op has been committed (ie, written to journal) by the
464   primary OSD
465 - op_applied: The op has been write()'en to the backing FS (ie, applied in
466   memory but not flushed out to disk) on the primary
467 - sub_op_applied: op_applied, but for a replica's "subop"
468 - sub_op_committed: op_commited, but for a replica's subop (only for EC pools)
469 - sub_op_commit_rec/sub_op_apply_rec from <X>: the primary marks this when it
470   hears about the above, but for a particular replica <X>
471 - commit_sent: we sent a reply back to the client (or primary OSD, for sub ops)
472
473 Many of these events are seemingly redundant, but cross important boundaries in
474 the internal code (such as passing data across locks into new threads).
475
476 Flapping OSDs
477 =============
478
479 We recommend using both a public (front-end) network and a cluster (back-end)
480 network so that you can better meet the capacity requirements of object
481 replication. Another advantage is that you can run a cluster network such that
482 it is not connected to the internet, thereby preventing some denial of service
483 attacks. When OSDs peer and check heartbeats, they use the cluster (back-end)
484 network when it's available. See `Monitor/OSD Interaction`_ for details.
485
486 However, if the cluster (back-end) network fails or develops significant latency
487 while the public (front-end) network operates optimally, OSDs currently do not
488 handle this situation well. What happens is that OSDs mark each other ``down``
489 on the monitor, while marking themselves ``up``. We call this scenario
490 'flapping`.
491
492 If something is causing OSDs to 'flap' (repeatedly getting marked ``down`` and
493 then ``up`` again), you can force the monitors to stop the flapping with::
494
495         ceph osd set noup      # prevent OSDs from getting marked up
496         ceph osd set nodown    # prevent OSDs from getting marked down
497
498 These flags are recorded in the osdmap structure::
499
500         ceph osd dump | grep flags
501         flags no-up,no-down
502
503 You can clear the flags with::
504
505         ceph osd unset noup
506         ceph osd unset nodown
507
508 Two other flags are supported, ``noin`` and ``noout``, which prevent
509 booting OSDs from being marked ``in`` (allocated data) or protect OSDs
510 from eventually being marked ``out`` (regardless of what the current value for
511 ``mon osd down out interval`` is).
512
513 .. note:: ``noup``, ``noout``, and ``nodown`` are temporary in the
514    sense that once the flags are cleared, the action they were blocking
515    should occur shortly after.  The ``noin`` flag, on the other hand,
516    prevents OSDs from being marked ``in`` on boot, and any daemons that
517    started while the flag was set will remain that way.
518
519
520
521
522
523
524 .. _iostat: http://en.wikipedia.org/wiki/Iostat
525 .. _Ceph Logging and Debugging: ../../configuration/ceph-conf#ceph-logging-and-debugging
526 .. _Logging and Debugging: ../log-and-debug
527 .. _Debugging and Logging: ../debug
528 .. _Monitor/OSD Interaction: ../../configuration/mon-osd-interaction
529 .. _Monitor Config Reference: ../../configuration/mon-config-ref
530 .. _monitoring your OSDs: ../../operations/monitoring-osd-pg
531 .. _subscribe to the ceph-devel email list: mailto:majordomo@vger.kernel.org?body=subscribe+ceph-devel
532 .. _unsubscribe from the ceph-devel email list: mailto:majordomo@vger.kernel.org?body=unsubscribe+ceph-devel
533 .. _subscribe to the ceph-users email list: mailto:ceph-users-join@lists.ceph.com
534 .. _unsubscribe from the ceph-users email list: mailto:ceph-users-leave@lists.ceph.com
535 .. _OS recommendations: ../../../start/os-recommendations
536 .. _ceph-devel: ceph-devel@vger.kernel.org