+<<<<<<< HEAD
Dell OPNFV Testlab
==================================================
User: opnfv
Passwd: d3ll1234
+=======
+Dell OPNFV Testlab\r
+==================================================\r
+\r
+Overview\r
+------------------\r
+\r
+Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project\r
+\r
+\r
+The Dell Testlab consists of 3 PODs for the use of the community\r
+ * POD1 (Jenkins slave: dell-us-testing-bm-1) \r
+ * POD2 (Jenkins slave: dell-us-deploying-bm2)\r
+ * POD3 (Jenkins slave: dell-us-delpoyingbm3) \r
+\r
+.. image:: images/Dell_Overview.jpg\r
+ :height: 648\r
+ :width: 735\r
+ :alt: Dell Testlab Overiew\r
+ :align: left\r
+\r
+Each of the 2 PODs consists of 6 servers that consist of\r
+ * 1 Jump Server\r
+ * 3 Servers for Control Nodes\r
+ * 2 Servers for Compute Nodes\r
+\r
+\r
+\r
+Hardware details\r
+-----------------\r
+\r
+For POD1 and POD2, the servers reside within a single Dell PowerEdge 620 chassis and have the following specifications:\r
+\r
+\r
+\r
+**POD1**\r
+\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Hostname | Model | Memory | Storage | Processor | Socket |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Jump Server | Dell PowerEdge M620 | 64 GB | 1200GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node2 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node3 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node4 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node5 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node6 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+\r
+\r
+\r
+\r
+**POD2**\r
+\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Hostname | Model | Memory | Storage | Processor | Socket |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Jump Server | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2630 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node7 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node8 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node9 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node11 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+| Node12 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |\r
++---------------------+----------------------+----------------+--------------+---------------------+------------+\r
+\r
+\r
+POD3 consists of 6 R630 Rack servers with the following specifications:\r
+\r
+**POD3**\r
+\r
++---------------------+----------------------+-----------------+--------------+---------------------+------------+\r
+| Hostname | Model | Memory | Storage | Processor | Socket |\r
++---------------------+----------------------+-----------------+--------------+---------------------+------------+\r
+| Jump Server | Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel Xeon E5-2698 | 2 |\r
++---------------------+----------------------+-----------------+--------------+---------------------+------------+\r
+| Node2 | Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel Xeon E5-2698 | 2 |\r
++---------------------+----------------------+-----------------+--------------+---------------------+------------+\r
+| Node3 | Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel Xeon E5-2698 | 2 |\r
++---------------------+----------------------+-----------------+--------------+---------------------+------------+\r
+| Node4 | Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel Xeon E5-2698 | 2 |\r
++---------------------+----------------------+-----------------+--------------+---------------------+------------+\r
+| Node5 | Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel Xeon E5-2698 | 2 |\r
++---------------------+----------------------+-----------------+--------------+---------------------+------------+\r
+| Node6 | Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel Xeon E5-2698 | 2 |\r
++---------------------+----------------------+----------------+---------------+---------------------+------------+\r
+\r
+\r
+\r
+Software\r
+---------\r
+\r
+The Jump servers in the Testlab are pre-provisioned with the following softwares:\r
+\r
+ * POD1-Jump Server:\r
+\r
+ 1. OS: Ubuntu 14.04\r
+\r
+\r
+ * POD2-Jump Server:\r
+\r
+ 1. OS: CentOS7.1\r
+\r
+\r
+ * POD3-Jump Server:\r
+\r
+ 1. OS: CentOS7.1\r
+\r
+\r
+Networks\r
+----------\r
+\r
+\r
+\r
+**POD1**\r
+\r
+.. image:: images/Dell_POD1.jpg\r
+ :height: 649\r
+ :width: 815\r
+ :alt: POD1-Fuel Overview\r
+ :align: left\r
+\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Hostname | NIC Model | Ports|MAC | BW | VLANs/Roles |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Jump Server | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B4:84 | 10G | Internal Networks (101-106) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B4:91 | 10G | Internal Networks (101-106) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B4:9E | 10G | Internal Networks (101-106) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B4:AB | 10G | Internal Networks (101-106) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B4:B8 | 10G | Internal Networks (101-106) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B4:C5 | 10G | Internal Networks (101-106) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+\r
+\r
+\r
+**POD2**\r
+\r
+.. image:: images/Dell_POD2.jpg\r
+ :height: 602\r
+ :width: 815\r
+ :alt: POD2 Overview\r
+ :align: left\r
+\r
+\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Hostname | NIC Model | Ports|MAC | BW | Roles |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:1D | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B5:20 | 10G | Internal Networks (201-205) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:21 | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B5:23 | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:CF | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B4:D2 | 10G | Internal Networks (201-205) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:D3 | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B4:D5 | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:D7 | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:DA | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:DC | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B4:DF | 10G | Internal Networks (201-205) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:E0 | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B4:E2 | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:E4 | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:E7 | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:E9 | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B4:EC | 10G | Internal Networks (201-205) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:ED | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B4:EF | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:F1 | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:F3 | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:03 | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B5:06 | 10G | Internal Networks (201-205) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:07 | 10G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B5:09 | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B5:0B | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B5:0D | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:10 | 10G | PXE |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | em2 | A4:1F:72:11:B5:13 | 10G | Internal Networks (201-205) |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:14 | 1G | Public |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p3p2 | A4:1F:72:11:B5:16 | 10G | Unused |\r
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+\r
+\r
+\r
+\r
+**POD3**\r
+\r
+\r
+\r
+.. image:: images/Dell_POD3.jpg\r
+ :height: 652\r
+ :width: 815\r
+ :alt: POD3 Overview\r
+ :align: left\r
+\r
+\r
+\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| Hostname | NIC Model | Ports|MAC | BW | Roles (VLANs) |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| Jump Server | 1, Intel 2P X520/2P I350 rNDC | em1 | EC:F4:BB:D7:14:20 | 1G | PXE |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | em2 | EC:F4:BB:D7:14:22 | 10G | Internal Networks (201,202,203) |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | p3p1 | EC:F4:BB:D7:14:24 | 1G | Public |\r
+| | | | | | |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| Node1 | 1, Intel 2P X520/2P I350 rNDC | em1 | EC:F4:BB:D6:F2:98 | 10G | PXE |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | em2 | EC:F4:BB:D6:F2:9A | 10G | Internal Networks (201,202,203) | \r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | p3p1 | EC:F4:BB:D6:F2:9C | 1G | Public |\r
+| | | | | | |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| Node2 | 1, Intel 2P X520/2P I350 rNDC | em1 | EC:F4:BB:D6:F9:10 | 1G | PXE |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | em2 | EC:F4:BB:D6:F9:12 | 10G | Internal Networks (201,202,203) |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | p3p1 | EC:F4:BB:D6:F9:14 | 1G | Public |\r
+| | | | | | |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| Node3 | 1, Intel 2P X520/2P I350 rNDC | em1 | EC:F4:BB:D7:C9:B8 | 1G | PXE |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | em2 | EC:F4:BB:D7:C9:BA | 10G | Internal Networks (201,202,203) |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | p3p1 | EC:F4:BB:D7:C9:BC | 1G | Public |\r
+| | | | | | |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| Node4 | 1, Intel 2P X520/2P I350 rNDC | em1 | EC:F4:BB:D7:16:E8 | 10G | PXE |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | em2 | EC:F4:BB:D7:16:EA | 10G | Internal Networks (201,202,203) | \r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | p3p1 | EC:F4:BB:D7:16:EA | 1G | Public |\r
+| | | | | | |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| Node5 | 1, Intel 2P X520/2P I350 rNDC | em1 | EC:F4:BB:D6:FE:98 | 1G | Unused |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | em2 | EC:F4:BB:D6:FE:9A | 10G | Internal Networks (201,202,203) |\r
+| | | | | | |\r
+| | +------+-------------------+-------+----------------------------------+\r
+| | | | | | |\r
+| | | p3p1 | EC:F4:BB:D6:FE:9C | 1G | Public |\r
+| | | | | | |\r
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+\r
+\r
+\r
+**Subnet allocations**\r
+\r
++-------------------+----------------+-------------------+---------------+----------+\r
+| Network name | Address | Mask | Gateway | VLAN id |\r
++-------------------+----------------+-------------------+---------------+----------+\r
+| POD1 Public | 172.18.0.64 | 255.255.255.192 | 172.18.0.65 | Untagged |\r
++-------------------+----------------+-------------------+---------------+----------+\r
+| POD2 Public | 172.18.0.0 | 255.255.255.192 | 172.18.0.1 | Untagged |\r
++-------------------+----------------+-------------------+---------------+----------+\r
+| POD3 Public | 172.18.1.0 | 255.255.255.0 | 172.18.1.1 | Untagged |\r
++-------------------+----------------+-------------------+---------------+----------+\r
+| Lights Out | 172.18.0.128 | 255.255.255.128 | 172.18.0.129 | Untagged |\r
++-------------------+----------------+-------------------+---------------+----------+\r
+\r
+\r
+**Lights out Network**\r
+\r
+**POD1**\r
+\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Hostname | Lights-out address | MAC | Username | Password |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Jump | 172.18.0.131 | A4:1F:72:11:B4:80| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node2 | 172.18.0.132 | A4:1F:72:11:B4:8D| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node3 | 172.18.0.133 | A4:1F:72:11:B4:9A| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node4 | 172.18.0.134 | A4:1F:72:11:B4:A7| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node5 | 172.18.0.135 | A4:1F:72:11:B4:B4| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node6 | 172.18.0.136 | A4:1F:72:11:B4:C1| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+\r
+**POD2**\r
+\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Hostname | Lights-out address | MAC | Username | Password |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Jump | 172.18.0.143 | A4:1F:72:11:B5:1C| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node7 | 172.18.0.137 | A4:1F:72:11:B4:CE| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node8 | 172.18.0.138 | A4:1F:72:11:B4:DB| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node9 | 172.18.0.139 | A4:1F:72:11:B4:E8| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node11 | 172.18.0.141 | A4:1F:72:11:B5:02| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node12 | 172.18.0.142 | A4:1F:72:11:B5:0F| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+\r
+\r
+\r
+**POD3**\r
+\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Hostname | Lights-out address | MAC | Username | Password |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Jump | 172.18.0.181 | 74:E6:E2:FA:BB:D8| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node1 | 172.18.0.182 | 74:E6:E2:FA:E9:2E| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node2 | 172.18.0.183 | 74:E6:E2:FA:FC:E2| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node3 | 172.18.0.184 | 74:E6:E2:FB:05:68| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node4 | 172.18.0.185 | 74:E6:E2:FA:A4:02| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+| Node5 | 172.18.0.186 | 74:E6:E2:FA:E4:18| root | calvin |\r
++----------------+-------------------------------+------------------+---------------------+---------------------+\r
+\r
+\r
+Remote access infrastructure\r
+-----------------------------\r
+\r
+The Dell OPNFV testlab is free to use for the OPNFV community.\r
+\r
+A VPN is used to provide access to the Dell Testlab.\r
+\r
+To access the Testlab, please visit the Dell OPNFV Lab's wiki page (https://wiki.opnfv.org/dell_hosting) for details.\r
+\r
+\r
+*Accessing the Teslab*\r
+-----------------------\r
+\r
+* POD1 JumpServer\r
+\r
+ IP: 172.18.0.67\r
+\r
+ User: opnfv\r
+\r
+ Passwd: d3ll1234\r
+\r
+\r
+\r
+* POD2 JumpServer\r
+\r
+ IP: 172.18.0.11\r
+\r
+ User: opnfv\r
+\r
+ Passwd: d3ll1234\r
+\r
+\r
+\r
+* POD3 JumpServer\r
+\r
+ IP: 172.18.1.3\r
+\r
+ User: opnfv\r
+\r
+ Passwd: d3ll1234\r
+>>>>>>> f71f6b6... Updated Dell Lab's Documentation