These changes are the raw update to linux-4.4.6-rt14. Kernel sources
[kvmfornfv.git] / kernel / drivers / hwmon / pmbus / Kconfig
1 #
2 # PMBus chip drivers configuration
3 #
4
5 menuconfig PMBUS
6         tristate "PMBus support"
7         depends on I2C
8         default n
9         help
10           Say yes here if you want to enable PMBus support.
11
12           This driver can also be built as a module. If so, the module will
13           be called pmbus_core.
14
15 if PMBUS
16
17 config SENSORS_PMBUS
18         tristate "Generic PMBus devices"
19         default y
20         help
21           If you say yes here you get hardware monitoring support for generic
22           PMBus devices, including but not limited to ADP4000, BMR453, BMR454,
23           MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, TPS40400, TPS544B20,
24           TPS544B25, TPS544C20, TPS544C25, and UDT020.
25
26           This driver can also be built as a module. If so, the module will
27           be called pmbus.
28
29 config SENSORS_ADM1275
30         tristate "Analog Devices ADM1275 and compatibles"
31         default n
32         help
33           If you say yes here you get hardware monitoring support for Analog
34           Devices ADM1075, ADM1275, ADM1276, ADM1293, and ADM1294 Hot-Swap
35           Controller and Digital Power Monitors.
36
37           This driver can also be built as a module. If so, the module will
38           be called adm1275.
39
40 config SENSORS_LM25066
41         tristate "National Semiconductor LM25066 and compatibles"
42         default n
43         help
44           If you say yes here you get hardware monitoring support for National
45           Semiconductor LM25056, LM25066, LM5064, and LM5066.
46
47           This driver can also be built as a module. If so, the module will
48           be called lm25066.
49
50 config SENSORS_LTC2978
51         tristate "Linear Technologies LTC2978 and compatibles"
52         default n
53         help
54           If you say yes here you get hardware monitoring support for Linear
55           Technology LTC2974, LTC2975, LTC2977, LTC2978, LTC2980, LTC3880,
56           LTC3883, LTC3886, LTC3887, LTCM2987, LTM4675, and LTM4676.
57
58           This driver can also be built as a module. If so, the module will
59           be called ltc2978.
60
61 config SENSORS_LTC2978_REGULATOR
62         bool "Regulator support for LTC2978 and compatibles"
63         depends on SENSORS_LTC2978 && REGULATOR
64         help
65           If you say yes here you get regulator support for Linear
66           Technology LTC2974, LTC2977, LTC2978, LTC3880, LTC3883, and LTM4676.
67
68 config SENSORS_MAX16064
69         tristate "Maxim MAX16064"
70         default n
71         help
72           If you say yes here you get hardware monitoring support for Maxim
73           MAX16064.
74
75           This driver can also be built as a module. If so, the module will
76           be called max16064.
77
78 config SENSORS_MAX20751
79         tristate "Maxim MAX20751"
80         default n
81         help
82           If you say yes here you get hardware monitoring support for Maxim
83           MAX20751.
84
85           This driver can also be built as a module. If so, the module will
86           be called max20751.
87
88 config SENSORS_MAX34440
89         tristate "Maxim MAX34440 and compatibles"
90         default n
91         help
92           If you say yes here you get hardware monitoring support for Maxim
93           MAX34440, MAX34441, MAX34446, MAX34460, and MAX34461.
94
95           This driver can also be built as a module. If so, the module will
96           be called max34440.
97
98 config SENSORS_MAX8688
99         tristate "Maxim MAX8688"
100         default n
101         help
102           If you say yes here you get hardware monitoring support for Maxim
103           MAX8688.
104
105           This driver can also be built as a module. If so, the module will
106           be called max8688.
107
108 config SENSORS_TPS40422
109         tristate "TI TPS40422"
110         default n
111         help
112           If you say yes here you get hardware monitoring support for TI
113           TPS40422.
114
115           This driver can also be built as a module. If so, the module will
116           be called tps40422.
117
118 config SENSORS_UCD9000
119         tristate "TI UCD90120, UCD90124, UCD9090, UCD90910"
120         default n
121         help
122           If you say yes here you get hardware monitoring support for TI
123           UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health
124           Controllers.
125
126           This driver can also be built as a module. If so, the module will
127           be called ucd9000.
128
129 config SENSORS_UCD9200
130         tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
131         default n
132         help
133           If you say yes here you get hardware monitoring support for TI
134           UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
135           Digital PWM System Controllers.
136
137           This driver can also be built as a module. If so, the module will
138           be called ucd9200.
139
140 config SENSORS_ZL6100
141         tristate "Intersil ZL6100 and compatibles"
142         default n
143         help
144           If you say yes here you get hardware monitoring support for Intersil
145           ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105,
146           ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for
147           Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464.
148
149           This driver can also be built as a module. If so, the module will
150           be called zl6100.