Add the rt linux 4.1.3-rt3 as base
[kvmfornfv.git] / kernel / Documentation / ABI / testing / sysfs-class-scsi_host
1 What:           /sys/class/scsi_host/hostX/isci_id
2 Date:           June 2011
3 Contact:        Dave Jiang <dave.jiang@intel.com>
4 Description:
5                 This file contains the enumerated host ID for the Intel
6                 SCU controller. The Intel(R) C600 Series Chipset SATA/SAS
7                 Storage Control Unit embeds up to two 4-port controllers in
8                 a single PCI device.  The controllers are enumerated in order
9                 which usually means the lowest number scsi_host corresponds
10                 with the first controller, but this association is not
11                 guaranteed.  The 'isci_id' attribute unambiguously identifies
12                 the controller index: '0' for the first controller,
13                 '1' for the second.
14
15 What:           /sys/class/scsi_host/hostX/acciopath_status
16 Date:           November 2013
17 Contact:        Stephen M. Cameron <scameron@beardog.cce.hp.com>
18 Description:    This file contains the current status of the "SSD Smart Path"
19                 feature of HP Smart Array RAID controllers using the hpsa
20                 driver.  SSD Smart Path, when enabled permits the driver to
21                 send i/o requests directly to physical devices that are part
22                 of a logical drive, bypassing the controllers firmware RAID
23                 stack for a performance advantage when possible.  A value of
24                 '1' indicates the feature is enabled, and the controller may
25                 use the direct i/o path to physical devices.  A value of zero
26                 means the feature is disabled and the controller may not use
27                 the direct i/o path to physical devices.  This setting is
28                 controller wide, affecting all configured logical drives on the
29                 controller.  This file is readable and writable.