Updated PDF and IDF for Ericsson Hardware
[kuberef.git] / hw_config / ericsson-pod1 / idf.yaml
1 # SPDX-license-identifier: Apache-2.0
2 ##############################################################################
3 # Copyright (c) 2020 Ericsson AB and others
4 # All rights reserved. This program and the accompanying materials
5 # are made available under the terms of the Apache License, Version 2.0
6 # which accompanies this distribution, and is available at
7 # http://www.apache.org/licenses/LICENSE-2.0
8 ##############################################################################
9 ---
10 ### ERICSSON POD 1 installer descriptor file ###
11 idf:
12   version: 0.1
13   net_config: &net_config
14     oob:
15       interface: 0
16       vlan: native
17       network: 10.0.20.0
18       gateway: 10.0.20.1
19       mask: 24
20       dns:
21         - 8.8.8.8
22     public:
23       interface: 1
24       vlan: 80
25       network: 100.64.200.6
26       gateway: 100.64.200.1
27       mask: 24
28       dns:
29         - 8.8.8.8
30   kubespray: &idf_kubespray
31     nodes_roles:
32       node1: [k8s-cluster, kube-master, etcd, vault]
33       node2: [k8s-cluster, kube-master, etcd]
34       node3: [k8s-cluster, kube-master, etcd]
35       node4: [k8s-cluster, kube-node]
36       node5: [k8s-cluster, kube-node]
37     groups:
38       k8s-cluster:
39         - kube-node
40         - kube-master
41     hostnames:
42       node1: master1
43       node2: master2
44       node3: master3
45       node4: node1
46       node5: node2
47     network:
48       # network mapping
49       network_mapping:
50         net_admin: oob
51         # Public network
52         net_public: public
53         # Management network used by installer components to communicate
54         net_mgmt: public
55
56 engine:
57   pod_name: ericsson-pod1
58   net_config: *net_config
59
60   # net_config network to be used by the PXE
61   pxe_network: oob
62
63   # net_config network to be used for the internet access
64   public_network: public
65
66   # interface to be used by the PXE
67   pxe_interface: ens4
68
69   installers:
70     kubespray: *idf_kubespray
71 bmra:
72   profile: full_nfv
73   network_roles:
74     sriov:
75       - name: eth2
76         bus_info: "05:00.0"
77         device_info: "8086:10f8:0200"
78         driver: vfio-pci
79     sriov_dpdk:
80       - name: eth3
81         bus_info: "05:00.1"
82         device_info: "8086:10f8:0200"
83         driver: vfio-pci
84   features:
85     sriov:
86       enable: false
87       sriov_vfs_per_port: 2
88       sriov_dpdk_vfs_per_port: 4
89     sriov_cni: false
90     sriov_net_dp: false
91     hugepages:
92       enable: false
93       default: 2M
94       hugepages_1G: 0
95       hugepages_2M: 10240
96     isolcpus:
97       enable: true
98       cpus: "4-9,14-19,24-29,34-39"
99     nfd: true
100     cmk:
101       enable: true
102       num_shared_cores: 3
103       num_exclusive_cores: 3
104     topology_manager:
105       enable: true
106       policy: "best-effort"
107     tas:
108       enable: true
109       demo_policy: false
110     psp: true