1 ==================================================================================================
2 OPNFV Installation instructions for the Arno release of OPNFV when using Fuel as a deployment tool
3 ==================================================================================================
5 .. contents:: Table of Contents
12 This document describes how to install the Arno release of OPNFV when using Fuel as a deployment tool covering it's limitations, dependencies and required system resources.
16 Arno release of OPNFV when using Fuel as a deployment tool Docs (c) by Jonas Bjurel (Ericsson AB)
18 Arno release of OPNFV when using Fuel as a deployment tool Docs are licensed under a Creative Commons Attribution 4.0 International License. You should have received a copy of the license along with this. If not, see <http://creativecommons.org/licenses/by/4.0/>.
23 +--------------------+--------------------+--------------------+--------------------+
24 | **Date** | **Ver.** | **Author** | **Comment** |
26 +--------------------+--------------------+--------------------+--------------------+
27 | 2015-04-15 | 0.0.1 | Jonas Bjurel | First draft |
28 | | | (Ericsson AB) | |
29 +--------------------+--------------------+--------------------+--------------------+
30 | 2015-04-23 | 0.0.2 | Jonas Bjurel | Minor changes |
31 | | | (Ericsson AB) | |
32 +--------------------+--------------------+--------------------+--------------------+
33 | 2015-05-16 | 0.0.3 | Christopher Price | Minor changes |
34 | | | (Ericsson AB) | |
35 +--------------------+--------------------+--------------------+--------------------+
36 | 2015-05-27 | 0.0.4 | Christopher Price | Minor changes |
37 | | | (Ericsson AB) | |
38 +--------------------+--------------------+--------------------+--------------------+
39 | 2015-06-02 | 0.0.5 | Christopher Price | Minor changes |
40 | | | (Ericsson AB) | |
41 +--------------------+--------------------+--------------------+--------------------+
47 This document describes providing guidelines on how to install and configure the Arno release of OPNFV when using Fuel as a deployment tool including required software and hardware configurations.
49 Although the available installation options gives a high degree of freedom in how the system is set-up including architecture, services and features, etc. said permutations may not provide an OPNFV compliant reference architecture. This instruction provides a step-by-step guide that results in an OPNFV Arno compliant deployment.
51 The audience of this document is assumed to have good knowledge in networking and Unix/Linux administration.
56 Before starting the installation of the Arno release of OPNFV when using Fuel as a deployment tool, some planning must be done.
58 Retrieving the ISO image
59 ------------------------
61 First of all, the Fuel deployment arnofuel.iso image needs to be retrieved, the .iso image of the Arno release of OPNFV when using Fuel as a deployment tool can be found here at http://artifacts.opnfv.org/arno.2015.1.0/fuel/arno.2015.1.0.fuel.iso
63 Building the ISO image
64 ----------------------
66 Alternatively, you may build the .iso from source by cloning the opnfv/genesis git repository. To retrieve the repository for the Arno release use the following command.
68 <git clone https://<linux foundation uid>@gerrit.opnf.org/gerrit/genesis>
70 Check-out the Arno release tag to set the branch to the baseline required to replicate the Arno release.
72 <cd genesis; git checkout arno.2015.1.0>
74 Go to the fuel directory and build the .iso
76 <cd fuel/build; make all>
78 For more information on how to build, please see "OPNFV Build instructions for - Arno release of OPNFV when using Fuel as a deployment tool which you retrieves with the repository at </genesis/fuel/docs/src/build-instructions.rst>
80 Next, familiarize yourself with the Fuel 6.0.1 version by reading the following documents:
82 - Fuel planning guide <http://docs.mirantis.com/openstack/fuel/fuel-6.0/planning-guide.html#planning-guide>
84 - Fuel user guide <http://docs.mirantis.com/openstack/fuel/fuel-6.0/user-guide.html#user-guide>
86 - Fuel operations guide <http://docs.mirantis.com/openstack/fuel/fuel-6.0/operations.html#operations-guide>
88 A number of deployment specific parameters must be collected, those are:
90 1. Provider sub-net and gateway information
92 2. Provider VLAN information
94 3. Provider DNS addresses
96 4. Provider NTP addresses
98 This information will be needed for the configuration procedures provided in this document.
100 Hardware requirements
101 =====================
103 The following minimum hardware requirements must be met for the installation of Arno using Fuel:
105 +--------------------+------------------------------------------------------+
106 | **HW Aspect** | **Requirement** |
108 +--------------------+------------------------------------------------------+
109 | **# of servers** | Minimum 5 (3 for non redundant deployment): |
111 | | - 1 Fuel deployment master (may be virtualized) |
113 | | - 3(1) Controllers |
116 +--------------------+------------------------------------------------------+
117 | **CPU** | Minimum 1 socket x86_AMD64 Ivy bridge 1.6 GHz |
119 +--------------------+------------------------------------------------------+
120 | **RAM** | Minimum 16GB/server (Depending on VNF work load) |
122 +--------------------+------------------------------------------------------+
123 | **Disk** | Minimum 256GB 10kRPM spinning disks |
125 +--------------------+------------------------------------------------------+
126 | **NICs** | - 2(1)x10GE Niantec for Private/Public (Redundant) |
128 | | - 2(1)x10GE Niantec for SAN (Redundant) |
130 | | - 2(1)x1GE for admin (PXE) and control (RabitMQ,etc) |
132 +--------------------+------------------------------------------------------+
134 Top of the rack (TOR) Configuration requirements
135 ================================================
137 The switching infrastructure provides connectivity for the OPNFV infrastructure operations, tenant networks (East/West) and provider connectivity (North/South bound connectivity); it also provides needed connectivity for the storage Area Network (SAN). To avoid traffic congestion, it is strongly suggested that three physically separated networks are used, that is: 1 physical network for administration and control, one physical network for tenant private and public networks, and one physical network for SAN. The switching connectivity can (but does not need to) be fully redundant, in such case it and comprises a redundant 10GE switch pair for each of the three physically separated networks.
139 The physical TOR switches are **not** automatically configured from the OPNFV reference platform. All the networks involved in the OPNFV infrastructure as well as the provider networks and the private tenant VLANs needs to be manually configured.
141 Manual configuration of the Arno hardware platform should be carried out according to the Pharos specification http://artifacts.opnfv.org/arno.2015.1.0/docs/pharos-spec.arno.2015.1.0.pdf
144 OPNFV Software installation and deployment
145 ==========================================
147 This section describes the installation of the OPNFV installation server (Fuel master) as well as the deployment of the full OPNFV reference platform stack across a server cluster.
151 1. Mount the built fuel.arno.2015.1.0.iso file as a boot device to the jump host server.
153 2. Reboot the jump host to establish the Fuel server.
155 - The system now boots from the ISO image.
157 3. Change the grub boot parameters
159 - When the grub boot menu shows up - Press Tab to edit the kernel parameters
161 - Change <showmenu=no> to <showmenu=yes>.
163 - Change <netmask=255.255.255.0> to <netmask=255.255.0.0>.
167 4. Wait until screen Fuel setup is shown (Note: This can take up to 30 minutes).
169 5. Select PXE Setup and change the following fields to appropriate values (example below):
171 - Static Pool Start 10.20.0.3
173 - Static Pool End 10.20.0.254
175 - DHCP Pool Start 10.20.128.3
177 - DHCP Pool End 10.20.128.254
179 6. Select DNS & Hostname and change the following fields to appropriate values:
181 - Hostname <CEE Region name>-fuel
183 - Domain <Domain Name>
185 - Search Domain <Search Domain Name>
187 - Hostname to test DNS <Hostname to test DNS>
189 7. Select Time Sync and change the following fields to appropriate values:
191 - NTP Server 1 <Customer NTP server 1>
193 - NTP Server 2 <Customer NTP server 2>
195 - NTP Server 3<Customer NTP server 3>
197 **Note: This step is only to pass the network sanity test, the actual ntp parameters will be set with the pre-deploy script.**
199 8. Start the installation.
201 - Select Quit Setup and press Save and Quit.
203 - Installation starts, wait until a screen with logon credentials is shown.
205 Note: This will take about 15 minutes.
207 Create an OPNFV Environment
208 ---------------------------
210 9. Connect to Fuel with a browser towards port 8000
212 10. Create and name a new OpenStack environment, to be installed.
214 11. Select <Juno on Ubuntu> or <Juno on CentOS> as per your which in the "OpenStack Release" field.
216 12. Select deployment mode.
218 - Select the Multi-node with HA.
220 13. Select compute node mode.
222 - Select KVM as hypervisor (unless you're not deploying bare metal or nested KVM/ESXI).
224 14. Select network mode.
226 - Select Neutron with VLAN segmentation
228 ** Note: This will later be overridden to VXLAN by OpenDaylight.**
230 15. Select Storage Back-ends.
232 - Select Ceph for Cinder and default for glance.
234 16. Select additional services.
236 - Check option <Install Celiometer (OpenStack Telemetry)>.
238 17. Create the new environment.
240 Configure the OPNFV environment
241 -------------------------------
243 18. Enable PXE booting
245 - For every controller and compute server: enable PXE Booting as the first boot device in the BIOS boot order menu and hard disk as the second boot device in the same menu.
247 19. Reboot all the control and compute blades.
249 20. Wait for the availability of nodes showing up in the Fuel GUI.
251 - Wait until all nodes are displayed in top right corner of the Fuel GUI: <total number of server> TOTAL NODES and <total number of servers> UNALLOCATED NODES.
253 21. Open the environment you previously created.
255 22. Open the networks tab.
257 23. Update the public network configuration.
259 Change the following fields to appropriate values:
261 - IP Range Start to <Public IP Address start>
263 - IP Range End to <Public IP Address end>
265 - CIDR to <CIDR for Public IP Addresses>
267 - Gateway to <Gateway for Public IP Addresses>
269 - Check VLAN tagging.
271 - Set appropriate VLAN id.
273 24. Update the management network configuration.
275 - Set CIDR to 172.16.255.128/25 (or as per your which).
277 - Check VLAN tagging.
279 - Set appropriate VLAN id.
281 25. Update the Neutron L2 configuration.
285 26. Update the Neutron L3 configuration.
287 - Set Internal network CIDR to an appropriate value
289 - Set Internal network gateway to an appropriate value
291 - Set Floating IP ranges.
297 28. Click "verify network" to check the network set-up consistency and connectivity
299 29. Update the storage configuration.
301 30. Open the nodes tab.
305 - Check <Controller and Telemetry MongoDB>.
307 - Check the three servers you want to be installed as Controllers in pane <Assign Role>.
309 - Click <Apply Changes>.
313 - Check nodes to be installed as compute nodes in pane Assign Role.
315 - Click <Apply Changes>.
317 32. Configure interfaces.
319 - Check Select <All> to select all nodes with Control, Telemetry, MongoDB and Compute node roles.
321 - Click <Configure Interfaces>
323 - Screen Configure interfaces on number of <number of nodes> nodes is shown.
325 - Assign interfaces (bonded) for mgmt-, admin-, private-, public- and storage networks
327 Deploy the OPNFV environment
328 ----------------------------
329 **NOTE: Before the deployment is performed, the OPNFV pre-deploy script must be run**
331 35. Run the pre-deploy script.
332 Log on as root to the Fuel node.
333 Print Fuel environment Id (fuel env)
334 #> id | status | name | mode | release_id | changes <id>| new | <CEE Region name>| ha_compact | 2 | <ite specific information>
336 36. Run the pre-deployment script (/opt/opnfv/pre-deploy.sh <id>)
337 As prompted for-, set the DNS servers to go into /etc/resolv.conf.
338 As prompted for-, set any Hosts file additions for controllers and compute nodes. You will be prompted for name, FQDN and IP for each entry. Press return when prompted for a name when you have completed your input.
339 As prompted for-, set NTP upstream configuration for controllers. You will be prompted for a NTP server each entry. Press return when prompted for a NTP server when you have completed your input.
341 37. Deploy the environment.
342 In the Fuel GUI, click Deploy Changes.
344 Installation health-check
345 =========================
347 Now that the OPNFV environment has been created, and before the post installation configurations is started, perform a system health check from the Fuel GUI:
349 - Select the “Health check” TAB.
350 - Select all test cases
351 - And click “Run tests”
353 All test cases except the following should pass:
355 Post installation and deployment actions
356 ========================================
374 :Authors: Jonas Bjurel (Ericsson AB)
377 **Documentation tracking**