@@ -261,7 +261,8 @@ physical resource from 'enabled' to 'going-to-maintenance' and a timeout [#timeo
 After receiving the MaintenanceRequest,the VIM decides on the actions to be taken
 based on maintenance policies predefined by the affected Consumer(s).
 
-.. [#timeout] Timeout is set by the Administrator and corresponds to the maximum time to empty the physical resources.
+.. [#timeout] Timeout is set by the Administrator and corresponds to the maximum time
+   to empty the physical resources.
 
 .. figure:: images/figure5a.png
    :name: figure5a
@@ -322,11 +323,12 @@ shown in :numref:`figure5c`.
 It consists of the following steps:
 
 5. The Consumer C3 switches to standby configuration (STBY).
-6. Instructions from Consumers C2/C3 are shared to VIM requesting certain actions to be performed (steps 6a, 6b).
-   The VIM executes the requested actions and sends back a NACK to consumer C2 (step 6d) as the
-   migration of the virtual resource(s) is not completed by the given timeout.
+6. Instructions from Consumers C2/C3 are shared to VIM requesting certain actions to be performed
+   (steps 6a, 6b). The VIM executes the requested actions and sends back a NACK to consumer C2
+   (step 6d) as the migration of the virtual resource(s) is not completed by the given timeout.
 7. The VIM switches the physical resources to "enabled" state.
-8. MaintenanceResponse is sent from VIM to inform the Administrator that the maintenance action cannot start.
+8. MaintenanceNotification is sent from VIM to inform the Administrator that the maintenance action
+   cannot start.
 
 
 ..
index 154f8e4..b8ff7f2 100644 (file)
@@ -61,6 +61,13 @@ Immediate Notification
 
     - Fault notifications cannot be received immediately by Ceilometer.
 
+* Solved by
+
+  + Event Alarm Evaluator:
+    https://specs.openstack.org/openstack/ceilometer-specs/specs/liberty/event-alarm-evaluator.html
+  + New OpenStack alarms and notifications project AODH:
+    http://docs.openstack.org/developer/aodh/
+
 Maintenance Notification
 ^^^^^^^^^^^^^^^^^^^^^^^^
 
@@ -98,7 +105,7 @@ Maintenance Notification
 
     - VIM user cannot receive maintenance notifications.
 
-* Related blueprints
+* Solved by
 
   + https://blueprints.launchpad.net/nova/+spec/service-status-notification
 
@@ -126,6 +133,10 @@ Normalization of data collection models
 
     - Normalized data format does not exist.
 
+* Solved by
+
+  + Specification in Section :ref:`southbound`.
+
 OpenStack
 ---------
 
@@ -157,7 +168,7 @@ ________________________________
     - Ceilometer seems to be unsuitable for monitoring medium and large scale
       NFVI deployments.
 
-* Related blueprints
+* Solved by
 
   + Usage of Zabbix for fault aggregation [ZABB]_. Zabbix can support a much
     higher number of fault events (up to 15 thousand events per second, but
@@ -189,13 +200,14 @@ ___________________________________
     - OpenStack Ceilometer does not monitor hardware and software to capture
       faults.
 
-   + Gap
+  + Gap
 
-     - Ceilometer is not able to detect and handle all faults listed in the Annex.
+    - Ceilometer is not able to detect and handle all faults listed in the Annex.
 
-* Related blueprints / workarounds
+* Solved by
 
-  - Use other dedicated monitoring tools like Zabbix or Monasca
+  + Use of dedicated monitoring tools like Zabbix or Monasca.
+    See :ref:`nfvi_faults`.
 
 Nova
 ^^^^
@@ -218,15 +230,14 @@ ________________________________________
 
   + To-be
 
-    - There needs to be API to change VM power_State in case host has failed.
-    - There needs to be API to change nova-compute state.
+    - The API shall support to change VM power state in case host has failed.
+    - The API shall support to change nova-compute state.
     - There could be single API to change different VM states for all VMs
-      belonging to specific host.
-    - As external system monitoring the infra calls these APIs change can be
-      fast and reliable.
-    - Correlation actions can be faster and automated as states are reliable.
-    - User will be able to read states from OpenStack and trust they are
-      correct.
+      belonging to a specific host.
+    - Support external systems that are monitoring the infrastructure and resources
+      that are able to call the API fast and reliable.
+    - Resource states are reliable such that correlation actions can be fast and automated.
+    - User shall be able to read states from OpenStack and trust they are correct.
 
   + As-is
 
@@ -240,12 +251,11 @@ ________________________________________
   + Gap
 
     - OpenStack does not change its states fast and reliably enough.
-    - There is API missing to have external system to change states and to
-      trust the states are then reliable (external system has fenced failed
-      host).
+    - The API does not support to have an external system to change states and to
+      trust the states are reliable (external system has fenced failed host).
     - User cannot read all the states from OpenStack nor trust they are right.
 
-* Related blueprints
+* Solved by
 
   + https://blueprints.launchpad.net/nova/+spec/mark-host-down
   + https://blueprints.launchpad.net/python-novaclient/+spec/support-force-down-service
@@ -309,7 +319,7 @@ _________________
       underlying root cause of failure. Knowing the root cause can help filter
       out unnecessary and overwhelming alarms.
 
-* Related blueprints / workarounds
+* Status
 
   + Monasca as of now lacks this feature, although the community is aware and
     working toward supporting it.
@@ -334,7 +344,7 @@ _________________
     - Sensor monitoring is very important. It provides operators status
       on the state of the physical infrastructure (e.g. temperature, fans).
 
-* Related blueprints / workarounds
+* Addressed by
 
   + Monasca can be configured to use third-party monitoring solutions (e.g.
     Nagios, Cacti) for retrieving additional data.
@@ -370,7 +380,10 @@ _____________________________
 
   + Gap
 
-    - Cause of the delay needs to be identified and fixed
+    - Cause of the delay is a periodic evaluation and notification. Periodicity is configured
+      as 30s default value and can be reduced to 5s but not below.
+      https://github.com/zabbix/zabbix/blob/trunk/conf/zabbix_server.conf#L329
+
 
 ..
  vim: set tabstop=4 expandtab textwidth=80:
index 4c89fdf..848d5a0 100644 (file)
@@ -728,6 +728,7 @@ Other areas that need alignment is the so called alarm state in NFV. Here we mus
 however consider what can be attributes of the notification vs. what should be a
 property of the alarm instance. This will be analyzed later.
 
+.. _southbound:
 
 Detailed southbound interface specification
 -------------------------------------------
index 8cb1961..2ebba0d 100644 (file)
@@ -1,6 +1,8 @@
 .. This work is licensed under a Creative Commons Attribution 4.0 International License.
 .. http://creativecommons.org/licenses/by/4.0
 
+.. _nfvi_faults:
+
 Annex: NFVI Faults
 =================================================