Clairify notification related architecture
[doctor.git] / requirements / 03-architecture.rst
1 High level architecture and general features
2 ============================================
3
4 Functional overview
5 -------------------
6
7 The Doctor project circles around two distinct use cases: 1) management of
8 failures of virtualized resources and 2) planned maintenance, e.g. migration, of
9 virtualized resources. Both of them may affect a VNF/application and the network
10 service it provides, but there is a difference in frequency and how they can be
11 handled.
12
13 Failures are spontaneous events that may or may not have an impact on the
14 virtual resources. The Consumer should as soon as possible react to the failure,
15 e.g., by switching to the STBY node. The Consumer will then instruct the VIM on
16 how to clean up or repair the lost virtual resources, i.e. restore the VM, VLAN
17 or virtualized storage. How much the applications are affected varies.
18 Applications with built-in HA support might experience a short decrease in
19 retainability (e.g. an ongoing session might be lost) while keeping availability
20 (establishment or re-establishment of sessions are not affected), whereas the
21 impact on applications without built-in HA may be more serious. How much the
22 network service is impacted depends on how the service is implemented. With
23 sufficient network redundancy the service may be unaffected even when a specific
24 resource fails.
25
26 On the other hand, planned maintenance impacting virtualized resources are events
27 that are known in advance. This group includes e.g. migration due to software
28 upgrades of OS and hypervisor on a compute host. Some of these might have been
29 requested by the application or its management solution, but there is also a
30 need for coordination on the actual operations on the virtual resources. There
31 may be an impact on the applications and the service, but since they are not
32 spontaneous events there is room for planning and coordination between the
33 application management organization and the infrastructure management
34 organization, including performing whatever actions that would be required to
35 minimize the problems.
36
37 Failure prediction is the process of pro-actively identifying situations that
38 may lead to a failure in the future unless acted on by means of maintenance
39 activities. From applications' point of view, failure prediction may impact them
40 in two ways: either the warning time is so short that the application or its
41 management solution does not have time to react, in which case it is equal to
42 the failure scenario, or there is sufficient time to avoid the consequences by
43 means of maintenance activities, in which case it is similar to planned
44 maintenance.
45
46 Architecture Overview
47 ---------------------
48
49 NFV and the Cloud platform provide virtual resources and related control
50 functionality to users and administrators. :num:`Figure #figure3` shows the high
51 level architecture of NFV focusing on the NFVI, i.e., the virtualized
52 infrastructure. The NFVI provides virtual resources, such as virtual machines
53 (VM) and virtual networks. Those virtual resources are used to run applications,
54 i.e. VNFs, which could be components of a network service which is managed by
55 the consumer of the NFVI. The VIM provides functionalities of controlling and
56 viewing virtual resources on hardware (physical) resources to the consumers,
57 i.e., users and administrators. OpenStack is a prominent candidate for this VIM.
58 The administrator may also directly control the NFVI without using the VIM.
59
60 Although OpenStack is the target upstream project where the new functional
61 elements (Controller, Notifier, Monitor, and Inspector) are expected to be
62 implemented, a particular implementation method is not assumed. Some of these
63 elements may sit outside of OpenStack and offer a northbound interface to
64 OpenStack.
65
66 General Features and Requirements
67 ---------------------------------
68
69 The following features are required for the VIM to achieve high availability of
70 applications (e.g., MME, S/P-GW) and the Network Services:
71
72 * Monitoring: Monitor physical and virtual resources.
73 * Detection: Detect unavailability of physical resources.
74 * Correlation and Cognition: Correlate faults and identify affected virtual
75   resources.
76 * Notification: Notify unavailable virtual resources to their Consumer(s).
77 * Recovery action: Execute actions to process fault recovery and maintenance.
78
79 The time interval between the instant that an event is detected by the
80 monitoring system and the Consumer notification of unavailable resources shall
81 be < 1 second (e.g., Step 1 to Step 4 in :num:`Figure #figure4` and :num:`Figure
82 #figure5`).
83
84 .. _figure3:
85
86 .. figure:: images/figure3.png
87    :width: 100%
88
89    High level architecture
90
91 Monitoring
92 ^^^^^^^^^^
93
94 The VIM shall monitor physical and virtual resources for unavailability and
95 suspicious behavior.
96
97 Detection
98 ^^^^^^^^^
99
100 The VIM shall detect unavailability and failures of physical resources that
101 might cause errors/faults in virtual resources running on top of them.
102 Unavailability of physical resource is detected by various monitoring and
103 managing tools for hardware and software components. This may include also
104 predicting upcoming faults. Note, fault prediction is out of scope of this
105 project and is investigated in the OPNFV "Data Collection for Failure
106 Prediction" project [PRED]_.
107
108 The fault items/events to be detected shall be configurable.
109
110 The configuration shall enable Failure Selection and Aggregation. Failure
111 aggregation means the VIM determines unavailability of physical resource from
112 more than two non-critical failures related to the same resource.
113
114 There are two types of unavailability - immediate and future:
115
116 * Immediate unavailability can be detected by setting traps of raw failures on
117   hardware monitoring tools.
118 * Future unavailability can be found by receiving maintenance instructions
119   issued by the administrator of the NFVI or by failure prediction mechanisms.
120
121 Correlation and Cognition
122 ^^^^^^^^^^^^^^^^^^^^^^^^^
123
124 The VIM shall correlate each fault to the impacted virtual resource, i.e., the
125 VIM shall identify unavailability of virtualized resources that are or will be
126 affected by failures on the physical resources under them. Unavailability of a
127 virtualized resource is determined by referring to the mapping of physical and
128 virtualized resources.
129
130 The relation from physical resources to virtualized resources shall be
131 configurable, as the cause of unavailability of virtualized resources can be
132 different in technologies and policies of deployment.
133
134 Failure aggregation is also required in this feature, e.g., a user may request
135 to be only notified if failures on more than two standby VMs in an (N+M)
136 deployment model occurred.
137
138 Notification
139 ^^^^^^^^^^^^
140
141 The VIM shall notify the alarm, i.e., unavailability of virtual resource(s), to
142 the Consumer owning it over the northbound interface, such that the Consumers
143 impacted by the failure can take appropriate actions to recover from the
144 failure.
145
146 The VIM shall also notify the unavailability of physical resources to its
147 Administrator.
148
149 All notifications shall be transferred immediately in order to minimize the
150 stalling time of the network service and to avoid over assignment caused by
151 delay of capability updates.
152
153 There may be multiple consumers, so the VIM has to find out the owner of a
154 faulty resource. Moreover, there may be a large number of virtual and physical
155 resources in a real deployment, so polling the state of all resources to the VIM
156 would lead to heavy signaling traffic. Thus, a publication/subscription
157 messaging model is better suited for these notifications, as notifications are
158 only sent to subscribed consumers.
159
160 Notifications will be send out along with the configuration by the consumer.
161 The configuration includes endpoint(s) in which the consumers can specify
162 multiple targets for the notification subscription, so that various and
163 multiple receiver functions can consume the notification message.
164 Also, the conditions for notifications shall be configurable, such that
165 the consumer can set according policies, e.g. whether it wants to receive
166 fault notifications or not.
167
168 Note: the VIM should only accept notification subscriptions for each resource
169 by its owner or administrator.
170 Notifications to the Consumer about the unavailability of virtualized
171 resources will include a description of the fault, preferably with sufficient
172 abstraction rather than detailed physical fault information.
173
174 Recovery Action
175 ^^^^^^^^^^^^^^^
176
177 In the basic "Fault management using ACT-STBY configuration" use case, no
178 automatic actions will be taken by the VIM, but all recovery actions executed by
179 the VIM and the NFVI will be instructed and coordinated by the Consumer.
180
181 In a more advanced use case, the VIM shall be able to recover the failed virtual 
182 resources according to a pre-defined behavior for that resource. In principle
183 this means that the owner of the resource (i.e., its consumer or administrator)
184 can define which recovery actions shall be taken by the VIM. Examples are a
185 restart of the VM, migration/evacuation of the VM, or no action.
186
187
188
189 High level northbound interface specification
190 ---------------------------------------------
191
192 Fault management
193 ^^^^^^^^^^^^^^^^
194
195 This interface allows the Consumer to subscribe to fault notification from the
196 VIM. Using a filter, the Consumer can narrow down which faults should be
197 notified. A fault notification may trigger the Consumer to switch from ACT to
198 STBY configuration and initiate fault recovery actions. A fault query
199 request/response message exchange allows the Consumer to find out about active
200 alarms at the VIM. A filter can be used to narrow down the alarms returned in
201 the response message.
202
203 .. _figure4:
204
205 .. figure:: images/figure4.png
206    :width: 100%
207
208    High-level message flow for fault management
209
210 The high level message flow for the fault management use case is shown in
211 :num:`Figure #figure4`.
212 It consists of the following steps:
213
214 1. The VIM monitors the physical and virtual resources and the fault management
215    workflow is triggered by a monitored fault event.
216 2. Event correlation, fault detection and aggregation in VIM. Note: this may
217    also happen after Step 3.
218 3. Database lookup to find the virtual resources affected by the detected fault.
219 4. Fault notification to Consumer.
220 5. The Consumer switches to standby configuration (STBY)
221 6. Instructions to VIM requesting certain actions to be performed on the
222    affected resources, for example migrate/update/terminate specific
223    resource(s). After reception of such instructions, the VIM is executing the
224    requested action, e.g., it will migrate or terminate a virtual resource.
225
226 NFVI Maintenance
227 ^^^^^^^^^^^^^^^^
228
229 The NFVI maintenance interface allows the Administrator to notify the VIM about
230 a planned maintenance operation on the NFVI. A maintenance operation may for
231 example be an update of the server firmware or the hypervisor. The
232 MaintenanceRequest message contains instructions to change the state of the
233 resource from 'normal' to 'maintenance'. After receiving the MaintenanceRequest,
234 the VIM will notify the Consumer about the planned maintenance operation,
235 whereupon the Consumer will switch to standby (STBY) configuration to allow the
236 maintenance action to be executed. After the request was executed successfully
237 (i.e., the physical resources have been emptied) or the operation resulted in an
238 error state, the VIM sends a MaintenanceResponse message back to the
239 Administrator.
240
241 .. _figure5:
242
243 .. figure:: images/figure5.png
244    :width: 100%
245
246    High-level message flow for NFVI maintenance
247
248 The high level message flow for the NFVI maintenance use case is shown in
249 :num:`Figure #figure5`.
250 It consists of the following steps:
251
252 1. Maintenance trigger received from administrator.
253 2. VIM switches the affected NFVI resources to "maintenance" state, i.e., the
254    NFVI resources are prepared for the maintenance operation. For example, the
255    virtual resources should not be used for further allocation/migration
256    requests and the VIM will coordinate with the Consumer on how to best empty
257    the physical resources.
258 3. Database lookup to find the virtual resources affected by the detected
259    maintenance operation.
260 4. StateChange notification to inform Consumer about planned maintenance
261    operation.
262 5. The Consumer switches to standby configuration (STBY)
263 6. Instructions from Consumer to VIM requesting certain actions to be performed
264    (step 6a). After receiving such instructions, the VIM executes the requested
265    action in order to empty the physical resources (step 6b) and informs the
266    Consumer is about the result of the actions. Note: this step is out of scope
267    of Doctor.
268 7. Maintenance response from VIM to inform the Administrator that the physical
269    machines have been emptied (or the operation resulted in an error state).
270 8. The Administrator is coordinating and executing the maintenance
271    operation/work on the NFVI. Note: this step is out of scope of Doctor.
272
273 Faults
274 ------
275
276 Faults in the listed elements need to be immediately notified to the Consumer in
277 order to perform an immediate action like live migration or switch to a hot
278 standby entity. In addition, the Administrator of the host should trigger a
279 maintenance action to, e.g., reboot the server or replace a defective hardware
280 element.
281
282 Faults can be of different severity, i.e., critical, warning, or
283 info. Critical faults require immediate action as a severe degradation of the
284 system has happened or is expected. Warnings indicate that the system
285 performance is going down: related actions include closer (e.g. more frequent)
286 monitoring of that part of the system or preparation for a cold migration to a
287 backup VM. Info messages do not require any action. We also consider a type
288 "maintenance", which is no real fault, but may trigger maintenance actions
289 like a re-boot of the server or replacement of a faulty, but redundant HW.
290
291 Faults can be gathered by, e.g., enabling SNMP and installing some open source
292 tools to catch and poll SNMP. When using for example Zabbix one can also put an
293 agent running on the hosts to catch any other fault. In any case of failure, the
294 Administrator should be notified. Table 1 provides a list of high level faults
295 that are considered within the scope of the Doctor project requiring immediate
296 action by the Consumer.
297
298
299 +------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
300 | Service          | Fault                                                                                                                     | Severity         | How to detect?    | Comment                                                                                  | Action to recover                                                    |
301 +------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
302 | Compute Hardware | Processor/CPU failure, CPU condition not ok                                                                               | Critical         | Zabbix            |                                                                                          | Switch to hot standby                                                |
303 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
304 |                  | Memory failure/Memory condition not ok                                                                                    | Critical         | Zabbix (IPMI)     |                                                                                          | Switch to hot standby                                                |
305 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
306 |                  | Network card failure, e.g. network adapter connectivity lost                                                              | Critical         | Zabbix/Ceilometer |                                                                                          | Switch to hot standby                                                |
307 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
308 |                  | Disk crash                                                                                                                | Info             | RAID monitoring   | Network storage is very redundant (e.g. RAID system) and can guarantee high availability | Inform OAM                                                           |
309 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
310 |                  | Storage controller                                                                                                        | Critical         | Zabbix (IPMI)     |                                                                                          | Live migration if storage is still accessible; otherwise hot standby |
311 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
312 |                  | PDU/power failure, power off, server reset                                                                                | Critical         | Zabbix/Ceilometer |                                                                                          | Switch to hot standby                                                |
313 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
314 |                  | Power degradation, power redundancy lost, power threshold exceeded                                                        | Warning          | SNMP              |                                                                                          | Live migration                                                       |
315 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
316 |                  | Chassis problem (.e.g fan degraded/failed, chassis power degraded), CPU fan problem, temperature/thermal condition not ok | Warning          | SNMP              |                                                                                          | Live migration                                                       |
317 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
318 |                  | Mainboard failure                                                                                                         | Critical         | Zabbix (IPMI)     |                                                                                          | Switch to hot standby                                                |
319 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
320 |                  | OS crash (e.g. kernel panic)                                                                                              | Critical         | Zabbix            |                                                                                          | Switch to hot standby                                                |
321 +------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
322 | Hypervisor       | System has restarted                                                                                                      | Critical         | Zabbix            |                                                                                          | Switch to hot standby                                                |
323 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
324 |                  | Hypervisor failure                                                                                                        | Warning/Critical | Zabbix/Ceilometer |                                                                                          | Evacuation/switch to hot standby                                     |
325 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
326 |                  | Zabbix/Ceilometer is unreachable                                                                                          | Warning          | ?                 |                                                                                          | Live migration                                                       |
327 +------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
328 | Network          | SDN/OpenFlow switch, controller degraded/failed                                                                           | Critical         | ?                 |                                                                                          | Switch to hot standby or reconfigure virtual network topology        |
329 +                  +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
330 |                  | Hardware failure of physical switch/router                                                                                | Warning          | SNMP              | Redundancy of physical infrastructure is reduced or no longer available                  | Live migration if possible, otherwise evacuation                     |
331 +------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+
332
333 ..
334  vim: set tabstop=4 expandtab textwidth=80: