1 Use cases and scenarios
2 =======================
3
4 Telecom services often have very high requirements on service performance. As a
5 consequence they often utilize redundancy and high availability (HA) mechanisms
6 for both the service and the platform. The HA support may be built-in or
7 provided by the platform. In any case, the HA support typically has a very fast
8 detection and reaction time to minimize service impact. The main changes
9 proposed in this document are about making a clear distinction between fault
10 management and recovery a) within the VIM/NFVI and b) High Availability support
11 for VNFs on the other, claiming that HA support within a VNF or as a service
12 from the platform is outside the scope of Doctor and is discussed in the High
13 Availability for OPNFV project. Doctor should focus on detecting and remediating
14 faults in the NFVI. This will ensure that applications come back to a fully
15 redundant configuration faster than before.
16
17 As an example, Telecom services can come with an Active-Standby (ACT-STBY)
18 configuration which is a (1+1) redundancy scheme. ACT and STBY nodes (aka
19 Physical Network Function (PNF) in ETSI NFV terminology) are in a hot standby
20 configuration. If an ACT node is unable to function properly due to fault or any
21 other reason, the STBY node is instantly made ACT, and affected services can be
22 provided without any service interruption.
23
24 The ACT-STBY configuration needs to be maintained. This means, when a STBY node
25 is made ACT, either the previously ACT node, after recovery, shall be made STBY,
26 or, a new STBY node needs to be configured. The actual operations to
27 instantiate/configure a new STBY are similar to instantiating a new VNF and
28 therefore are outside the scope of this project.
29
30 The NFVI fault management and maintenance requirements aim at providing fast
31 failure detection of physical and virtualized resources and remediation of the
32 virtualized resources provided to Consumers according to their predefined
33 request to enable applications to recover to a fully redundant mode of
34 operation.
35
36 1. Fault management/recovery using ACT-STBY configuration (Triggered by critical
37    error)
38 2. Preventive actions based on fault prediction (Preventing service stop by
39    handling warnings)
40 3. VM Retirement (Managing service during NFVI maintenance, i.e. H/W,
41    Hypervisor, Host OS, maintenance)
42
43 Faults
44 ------
45
46 .. _uc-fault1:
47
48 Fault management using ACT-STBY configuration
49 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
50
51 In :numref:`figure1`, a system-wide view of relevant functional blocks is
52 presented. OpenStack is considered as the VIM implementation (aka Controller)
53 which has interfaces with the NFVI and the Consumers. The VNF implementation is
54 represented as different virtual resources marked by different colors. Consumers
55 (VNFM or NFVO in ETSI NFV terminology) own/manage the respective virtual
56 resources (VMs in this example) shown with the same colors.
57
58 The first requirement in this use case is that the Controller needs to detect
59 faults in the NVFI ("1. Fault Notification" in :numref:`figure1`) affecting
60 the proper functioning of the virtual resources (labelled as VM-x) running on
61 top of it. It should be possible to configure which relevant fault items should
62 be detected. The VIM (e.g. OpenStack) itself could be extended to detect such
63 faults. Alternatively, a third party fault monitoring tool could be used which
64 then informs the VIM about such faults; this third party fault monitoring
65 element can be considered as a component of VIM from an architectural point of
66 view.
67
68 Once such fault is detected, the VIM shall find out which virtual resources are
69 affected by this fault. In the example in :numref:`figure1`, VM-4 is
70 affected by a fault in the Hardware Server-3. Such mapping shall be maintained
71 in the VIM, depicted as the "Server-VM info" table inside the VIM.
72
73 Once the VIM has identified which virtual resources are affected by the fault,
74 it needs to find out who is the Consumer (i.e. the owner/manager) of the
75 affected virtual resources (Step 2). In the example shown in :numref:`figure1`,
76 the VIM knows that for the red VM-4, the manager is the red Consumer
77 through an Ownership info table. The VIM then notifies (Step 3 "Fault
78 Notification") the red Consumer about this fault, preferably with sufficient
79 abstraction rather than detailed physical fault information.
80
81 .. figure:: images/figure1.png
82    :name: figure1
83    :width: 100%
84
85    Fault management/recovery use case
86
87 The Consumer then switches to STBY configuration by switching the STBY node to
88 ACT state (Step 4). It further initiates a process to instantiate/configure a
89 new STBY. However, switching to STBY mode and creating a new STBY machine is a
90 VNFM/NFVO level operation and therefore outside the scope of this project.
91 Doctor project does not create interfaces for such VNFM level configuration
92 operations. Yet, since the total failover time of a consumer service depends on
93 both the delay of such processes as well as the reaction time of Doctor
94 components, minimizing Doctor's reaction time is a necessary basic ingredient to
95 fast failover times in general.
96
97 Once the Consumer has switched to STBY configuration, it notifies (Step 5
98 "Instruction" in :numref:`figure1`) the VIM. The VIM can then take
99 necessary (e.g. pre-determined by the involved network operator) actions on how
100 to clean up the fault affected VMs (Step 6 "Execute Instruction").
101
102 The key issue in this use case is that a VIM (OpenStack in this context) shall
103 not take a standalone fault recovery action (e.g. migration of the affected VMs)
104 before the ACT-STBY switching is complete, as that might violate the ACT-STBY
105 configuration and render the node out of service.
106
107 As an extension of the 1+1 ACT-STBY resilience pattern, a STBY instance can act as
108 backup to N ACT nodes (N+1). In this case, the basic information flow remains
109 the same, i.e., the consumer is informed of a failure in order to activate the
110 STBY node. However, in this case it might be useful for the failure notification
111 to cover a number of failed instances due to the same fault (e.g., more than one
112 instance might be affected by a switch failure). The reaction of the consumer
113 might depend on whether only one active instance has failed (similar to the
114 ACT-STBY case), or if more active instances are needed as well.
115
116 Preventive actions based on fault prediction
117 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
118
119 The fault management scenario explained in :ref:`uc-fault1` can also be
120 performed based on fault prediction. In such cases, in VIM, there is an
121 intelligent fault prediction module which, based on its NFVI monitoring
122 information, can predict an imminent fault in the elements of NFVI.
123 A simple example is raising temperature of a Hardware Server which might
124 trigger a pre-emptive recovery action. The requirements of such fault
125 prediction in the VIM are investigated in the OPNFV project "Data Collection
126 for Failure Prediction" [PRED]_.
127
128 This use case is very similar to :ref:`uc-fault1`. Instead of a fault
129 detection (Step 1 "Fault Notification in" :numref:`figure1`), the trigger
130 comes from a fault prediction module in the VIM, or from a third party module
131 which notifies the VIM about an imminent fault. From Step 2~5, the work flow is
132 the same as in the "Fault management using ACT-STBY configuration" use case,
133 except in this case, the Consumer of a VM/VNF switches to STBY configuration
134 based on a predicted fault, rather than an occurred fault.
135
136 NVFI Maintenance
137 ----------------
138
139 VM Retirement
140 ^^^^^^^^^^^^^
141
142 All network operators perform maintenance of their network infrastructure, both
143 regularly and irregularly. Besides the hardware, virtualization is expected to
144 increase the number of elements subject to such maintenance as NFVI holds new
145 elements like the hypervisor and host OS. Maintenance of a particular resource
146 element e.g. hardware, hypervisor etc. may render a particular server hardware
147 unusable until the maintenance procedure is complete.
148
149 However, the Consumer of VMs needs to know that such resources will be
150 unavailable because of NFVI maintenance. The following use case is again to
151 ensure that the ACT-STBY configuration is not violated. A stand-alone action
152 (e.g. live migration) from VIM/OpenStack to empty a physical machine so that
153 consequent maintenance procedure could be performed may not only violate the
154 ACT-STBY configuration, but also have impact on real-time processing scenarios
155 where dedicated resources to virtual resources (e.g. VMs) are necessary and a
156 pause in operation (e.g. vCPU) is not allowed. The Consumer is in a position to
157 safely perform the switch between ACT and STBY nodes, or switch to an
158 alternative VNF forwarding graph so the hardware servers hosting the ACT nodes
159 can be emptied for the upcoming maintenance operation. Once the target hardware
160 servers are emptied (i.e. no virtual resources are running on top), the VIM can
161 mark them with an appropriate flag (i.e. "maintenance" state) such that these
162 servers are not considered for hosting of virtual machines until the maintenance
163 flag is cleared (i.e. nodes are back in "normal" status).
164
165 A high-level view of the maintenance procedure is presented in :numref:`figure2`.
166 VIM/OpenStack, through its northbound interface, receives a maintenance notification
167 (Step 1 "Maintenance Request") from the Administrator (e.g. a network operator)
168 including information about which hardware is subject to maintenance.
169 Maintenance operations include replacement/upgrade of hardware,
170 update/upgrade of the hypervisor/host OS, etc.
171
172 The consequent steps to enable the Consumer to perform ACT-STBY switching are
173 very similar to the fault management scenario. From VIM/OpenStack's internal
174 database, it finds out which virtual resources (VM-x) are running on those
175 particular Hardware Servers and who are the managers of those virtual resources
176 (Step 2). The VIM then informs the respective Consumer (VNFMs or NFVO) in Step 3
177 "Maintenance Notification". Based on this, the Consumer takes necessary actions
178 (Step 4, e.g. switch to STBY configuration or switch VNF forwarding graphs) and
179 then notifies (Step 5 "Instruction") the VIM. Upon receiving such notification,
180 the VIM takes necessary actions (Step 6 "Execute Instruction" to empty the
181 Hardware Servers so that consequent maintenance operations could be performed.
182 Due to the similarity for Steps 2~6, the maintenance procedure and the fault
183 management procedure are investigated in the same project.
184
185 .. figure:: images/figure2.png
186    :name: figure2
187    :width: 100%
188
189    Maintenance use case
190