Merge "src: update to use collectd 5.8.0"
[barometer.git] / docs / release / userguide / feature.userguide.rst
1 .. This work is licensed under a Creative Commons Attribution 4.0 International License.
2 .. http://creativecommons.org/licenses/by/4.0
3 .. (c) <optionally add copywriters name>
4
5 ===================================
6 OPNFV Barometer User Guide
7 ===================================
8
9 Barometer collectd plugins description
10 ---------------------------------------
11 .. Describe the specific features and how it is realised in the scenario in a brief manner
12 .. to ensure the user understand the context for the user guide instructions to follow.
13
14 Collectd is a daemon which collects system performance statistics periodically
15 and provides a variety of mechanisms to publish the collected metrics. It
16 supports more than 90 different input and output plugins. Input plugins
17 retrieve metrics and publish them to the collectd deamon, while output plugins
18 publish the data they receive to an end point. collectd also has infrastructure
19 to support thresholding and notification.
20
21 Barometer has enabled the following collectd plugins:
22
23 * *dpdkstat plugin*: A read plugin that retrieves stats from the DPDK extended
24   NIC stats API.
25
26 * *dpdkevents plugin*:  A read plugin that retrieves DPDK link status and DPDK
27   forwarding cores liveliness status (DPDK Keep Alive).
28
29 * `gnocchi plugin`_: A write plugin that pushes the retrieved stats to
30   Gnocchi. It's capable of pushing any stats read through collectd to
31   Gnocchi, not just the DPDK stats.
32
33 * `aodh plugin`_: A notification plugin that pushes events to Aodh, and
34   creates/updates alarms appropriately.
35
36 * *hugepages plugin*:  A read plugin that retrieves the number of available
37   and free hugepages on a platform as well as what is available in terms of
38   hugepages per socket.
39
40 * *Open vSwitch events Plugin*: A read plugin that retrieves events from OVS.
41
42 * *Open vSwitch stats Plugin*: A read plugin that retrieves flow and interface
43   stats from OVS.
44
45 * *mcelog plugin*: A read plugin that uses mcelog client protocol to check for
46   memory Machine Check Exceptions and sends the stats for reported exceptions.
47
48 * *PMU plugin*: A read plugin that provides performance counters data on
49   Intel CPUs using Linux perf interface.
50
51 * *RDT plugin*: A read plugin that provides the last level cache utilization and
52   memory bandwidth utilization.
53
54 * *virt*: A read plugin that uses virtualization API *libvirt* to gather
55   statistics about virtualized guests on a system directly from the hypervisor,
56   without a need to install collectd instance on the guest.
57
58 * *SNMP Agent*: A write plugin that will act as a AgentX subagent that receives
59   and handles queries from SNMP master agent and returns the data collected
60   by read plugins. The SNMP Agent plugin handles requests only for OIDs
61   specified in configuration file. To handle SNMP queries the plugin gets data
62   from collectd and translates requested values from collectd's internal format
63   to SNMP format. Supports SNMP: get, getnext and walk requests.
64
65 All the plugins above are available on the collectd master, except for the
66 Gnocchi and Aodh plugins as they are Python-based plugins and only C plugins
67 are accepted by the collectd community. The Gnocchi and Aodh plugins live in
68 the OpenStack repositories.
69
70 Other plugins existing as a pull request into collectd master:
71
72 * *Legacy/IPMI*: A read plugin that reports platform thermals, voltages,
73   fanspeed, current, flow, power etc. Also, the plugin monitors Intelligent
74   Platform Management Interface (IPMI) System Event Log (SEL) and sends the
75   appropriate notifications based on monitored SEL events.
76
77 * *PCIe AER*: A read plugin that monitors PCIe standard and advanced errors and
78   sends notifications about those errors.
79
80
81 Third party application in Barometer repository:
82
83 * *Open vSwitch PMD stats*: An aplication that retrieves PMD stats from OVS. It is run
84   through exec plugin.
85
86 **Plugins and application included in the Euphrates release:**
87
88 Write Plugins: aodh plugin, SNMP agent plugin, gnocchi plugin.
89
90 Read Plugins/application: Intel RDT plugin, virt plugin, Open vSwitch stats plugin,
91 Open vSwitch PMD stats application.
92
93 Collectd capabilities and usage
94 ------------------------------------
95 .. Describe the specific capabilities and usage for <XYZ> feature.
96 .. Provide enough information that a user will be able to operate the feature on a deployed scenario.
97
98 .. note:: Plugins included in the OPNFV E release will be built-in for Apex integration
99  and can be configured as shown in the examples below.
100
101  The collectd plugins in OPNFV are configured with reasonable defaults, but can
102  be overridden.
103
104 Building all Barometer upstreamed plugins from scratch
105 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
106 The plugins that have been merged to the collectd master branch can all be
107 built and configured through the barometer repository.
108
109 .. note::
110  * sudo permissions are required to install collectd.
111  * These instructions are for Centos 7.
112
113 To build all the upstream plugins, clone the barometer repo:
114
115 .. code:: c
116
117     $ git clone https://gerrit.opnfv.org/gerrit/barometer
118
119 To install collectd as a service and install all it's dependencies:
120
121 .. code:: bash
122
123     $ cd barometer/systems && ./build_base_machine.sh
124
125 This will install collectd as a service and the base install directory
126 will be /opt/collectd.
127
128 Sample configuration files can be found in '/opt/collectd/etc/collectd.conf.d'
129
130 .. note::
131   If you don't want to use one of the Barometer plugins, simply remove the
132   sample config file from '/opt/collectd/etc/collectd.conf.d'
133 .. note::
134   If you plan on using the Exec plugin (for OVS_PMD_STATS or for executing scripts
135   on notification generation), the plugin requires a non-root user to execute scripts.
136   By default, `collectd_exec` user is used in the exec.conf provided in the sample
137   configurations directory under src/collectd in the Barometer repo. These scripts *DO NOT* create this user.
138   You need to create this user or modify the configuration in the sample configurations directory
139   under src/collectd to use another existing non root user before  running build_base_machine.sh.
140
141 .. note::
142   If you are using any Open vSwitch plugins you need to run:
143
144 .. code:: bash
145
146     $ sudo ovs-vsctl set-manager ptcp:6640
147
148 After this, you should be able to start collectd as a service
149
150 .. code:: bash
151
152     $ sudo systemctl status collectd
153
154 If you want to use granfana to display the metrics you collect, please see:
155 `grafana guide`_
156
157 For more information on configuring and installing OpenStack plugins for
158 collectd, check out the `collectd-ceilometer-plugin GSG`_.
159
160 Below is the per plugin installation and configuration guide, if you only want
161 to install some/particular plugins.
162
163 DPDK plugins
164 ^^^^^^^^^^^^^
165 Repo: https://github.com/collectd/collectd
166
167 Branch: master
168
169 Dependencies: DPDK (http://dpdk.org/)
170
171 .. note:: DPDK statistics plugin requires DPDK version 16.04 or later.
172
173 To build and install DPDK to /usr please see:
174 https://github.com/collectd/collectd/blob/master/docs/BUILD.dpdkstat.md
175
176 Building and installing collectd:
177
178 .. code:: bash
179
180     $ git clone https://github.com/collectd/collectd.git
181     $ cd collectd
182     $ ./build.sh
183     $ ./configure --enable-syslog --enable-logfile --enable-debug
184     $ make
185     $ sudo make install
186
187 .. note:: If DPDK was installed in a non standard location you will need to
188     specify paths to the header files and libraries using *LIBDPDK_CPPFLAGS* and
189     *LIBDPDK_LDFLAGS*. You will also need to add the DPDK library symbols to the
190     shared library path using *ldconfig*. Note that this update to the shared
191     library path is not persistant (i.e. it will not survive a reboot).
192
193 Example of specifying custom paths to DPDK headers and libraries:
194
195 .. code:: bash
196
197     $ ./configure LIBDPDK_CPPFLAGS="path to DPDK header files" LIBDPDK_LDFLAGS="path to DPDK libraries"
198
199 This will install collectd to default folder ``/opt/collectd``. The collectd
200 configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``.
201 To configure the dpdkstats plugin you need to modify the configuration file to
202 include:
203
204 .. code:: bash
205
206     LoadPlugin dpdkstat
207     <Plugin dpdkstat>
208        Coremask "0xf"
209        ProcessType "secondary"
210        FilePrefix "rte"
211        EnabledPortMask 0xffff
212        PortName "interface1"
213        PortName "interface2"
214     </Plugin>
215
216
217 To configure the dpdkevents plugin you need to modify the configuration file to
218 include:
219
220 .. code:: bash
221
222     <LoadPlugin dpdkevents>
223       Interval 1
224     </LoadPlugin>
225
226     <Plugin "dpdkevents">
227       <EAL>
228         Coremask "0x1"
229         MemoryChannels "4"
230         FilePrefix "rte"
231       </EAL>
232       <Event "link_status">
233         SendEventsOnUpdate false
234         EnabledPortMask 0xffff
235         SendNotification true
236       </Event>
237       <Event "keep_alive">
238         SendEventsOnUpdate false
239         LCoreMask "0xf"
240         KeepAliveShmName "/dpdk_keepalive_shm_name"
241         SendNotification true
242       </Event>
243     </Plugin>
244
245 .. note:: Currently, the DPDK library doesn’t support API to de-initialize
246  the DPDK resources allocated on the initialization. It means, the collectd
247  plugin will not be able to release the allocated DPDK resources
248  (locks/memory/pci bindings etc.) correctly on collectd shutdown or reinitialize
249  the DPDK library if primary DPDK process is restarted. The only way to release
250  those resources is to terminate the process itself. For this reason, the plugin
251  forks off a separate collectd process. This child process becomes a secondary
252  DPDK process which can be run on specific CPU cores configured by user through
253  collectd configuration file (“Coremask” EAL configuration option, the
254  hexadecimal bitmask of the cores to run on).
255
256 For more information on the plugin parameters, please see:
257 https://github.com/collectd/collectd/blob/master/src/collectd.conf.pod
258
259 .. note:: dpdkstat plugin initialization time depends on read interval. It
260  requires 5 read cycles to set up internal buffers and states, during that time
261  no statistics are submitted. Also, if plugin is running and the number of DPDK
262  ports is increased, internal buffers are resized. That requires 3 read cycles
263  and no port statistics are submitted during that time.
264
265 The Address-Space Layout Randomization (ASLR) security feature in Linux should be
266 disabled, in order for the same hugepage memory mappings to be present in all
267 DPDK multi-process applications.
268
269 To disable ASLR:
270
271 .. code:: bash
272
273     $ sudo echo 0 > /proc/sys/kernel/randomize_va_space
274
275 To fully enable ASLR:
276
277 .. code:: bash
278
279     $ sudo echo 2 > /proc/sys/kernel/randomize_va_space
280
281 .. warning:: Disabling Address-Space Layout Randomization (ASLR) may have security
282     implications. It is recommended to be disabled only when absolutely necessary,
283     and only when all implications of this change have been understood.
284
285 For more information on multi-process support, please see:
286 http://dpdk.org/doc/guides/prog_guide/multi_proc_support.html
287
288 **DPDK stats plugin limitations:**
289
290 1. The DPDK primary process application should use the same version of DPDK
291    that collectd DPDK plugin is using;
292
293 2. L2 statistics are only supported;
294
295 3. The plugin has been tested on Intel NIC’s only.
296
297 **DPDK stats known issues:**
298
299 * DPDK port visibility
300
301   When network port controlled by Linux is bound to DPDK driver, the port
302   will not be available in the OS. It affects the SNMP write plugin as those
303   ports will not be present in standard IF-MIB. Thus, additional work is
304   required to be done to support DPDK ports and statistics.
305
306 Hugepages Plugin
307 ^^^^^^^^^^^^^^^^^
308 Repo: https://github.com/collectd/collectd
309
310 Branch: master
311
312 Dependencies: None, but assumes hugepages are configured.
313
314 To configure some hugepages:
315
316 .. code:: bash
317
318    $ sudo mkdir -p /mnt/huge
319    $ sudo mount -t hugetlbfs nodev /mnt/huge
320    $ sudo bash -c "echo 14336 > /sys/devices/system/node/node0/hugepages/hugepages-2048kB/nr_hugepages"
321
322 Building and installing collectd:
323
324 .. code:: bash
325
326     $ git clone https://github.com/collectd/collectd.git
327     $ cd collectd
328     $ ./build.sh
329     $ ./configure --enable-syslog --enable-logfile --enable-hugepages --enable-debug
330     $ make
331     $ sudo make install
332
333 This will install collectd to default folder ``/opt/collectd``. The collectd
334 configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``.
335 To configure the hugepages plugin you need to modify the configuration file to
336 include:
337
338 .. code:: bash
339
340     LoadPlugin hugepages
341     <Plugin hugepages>
342         ReportPerNodeHP  true
343         ReportRootHP     true
344         ValuesPages      true
345         ValuesBytes      false
346         ValuesPercentage false
347     </Plugin>
348
349 For more information on the plugin parameters, please see:
350 https://github.com/collectd/collectd/blob/master/src/collectd.conf.pod
351
352 Intel PMU Plugin
353 ^^^^^^^^^^^^^^^^
354 Repo: https://github.com/collectd/collectd
355
356 Branch: master
357
358 Dependencies:
359
360   * PMU tools (jevents library) https://github.com/andikleen/pmu-tools
361
362 To be suitable for use in collectd plugin shared library *libjevents* should be
363 compiled as position-independent code. To do this add the following line to
364 *pmu-tools/jevents/Makefile*:
365
366 .. code:: bash
367
368     CFLAGS += -fPIC
369
370 Building and installing *jevents* library:
371
372 .. code:: bash
373
374     $ git clone https://github.com/andikleen/pmu-tools.git
375     $ cd pmu-tools/jevents/
376     $ make
377     $ sudo make install
378
379 Building and installing collectd:
380
381 .. code:: bash
382
383     $ git clone https://github.com/collectd/collectd.git
384     $ cd collectd
385     $ ./build.sh
386     $ ./configure --enable-syslog --enable-logfile --with-libjevents=/usr/local --enable-debug
387     $ make
388     $ sudo make install
389
390 This will install collectd to default folder ``/opt/collectd``. The collectd
391 configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``.
392 To configure the PMU plugin you need to modify the configuration file to
393 include:
394
395 .. code:: bash
396
397     <LoadPlugin intel_pmu>
398       Interval 1
399     </LoadPlugin>
400     <Plugin "intel_pmu">
401       ReportHardwareCacheEvents true
402       ReportKernelPMUEvents true
403       ReportSoftwareEvents true
404     </Plugin>
405
406 For more information on the plugin parameters, please see:
407 https://github.com/collectd/collectd/blob/master/src/collectd.conf.pod
408
409 .. note::
410
411     The plugin opens file descriptors whose quantity depends on number of
412     monitored CPUs and number of monitored counters. Depending on configuration,
413     it might be required to increase the limit on the number of open file
414     descriptors allowed. This can be done using 'ulimit -n' command. If collectd
415     is executed as a service 'LimitNOFILE=' directive should be defined in
416     [Service] section of *collectd.service* file.
417
418 Intel RDT Plugin
419 ^^^^^^^^^^^^^^^^
420 Repo: https://github.com/collectd/collectd
421
422 Branch: master
423
424 Dependencies:
425
426   * PQoS/Intel RDT library https://github.com/01org/intel-cmt-cat.git
427   * msr kernel module
428
429 Building and installing PQoS/Intel RDT library:
430
431 .. code:: bash
432
433     $ git clone https://github.com/01org/intel-cmt-cat.git
434     $ cd intel-cmt-cat
435     $ make
436     $ make install PREFIX=/usr
437
438 You will need to insert the msr kernel module:
439
440 .. code:: bash
441
442     $ modprobe msr
443
444 Building and installing collectd:
445
446 .. code:: bash
447
448     $ git clone https://github.com/collectd/collectd.git
449     $ cd collectd
450     $ ./build.sh
451     $ ./configure --enable-syslog --enable-logfile --with-libpqos=/usr/ --enable-debug
452     $ make
453     $ sudo make install
454
455 This will install collectd to default folder ``/opt/collectd``. The collectd
456 configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``.
457 To configure the RDT plugin you need to modify the configuration file to
458 include:
459
460 .. code:: bash
461
462     <LoadPlugin intel_rdt>
463       Interval 1
464     </LoadPlugin>
465     <Plugin "intel_rdt">
466       Cores ""
467     </Plugin>
468
469 For more information on the plugin parameters, please see:
470 https://github.com/collectd/collectd/blob/master/src/collectd.conf.pod
471
472 IPMI Plugin
473 ^^^^^^^^^^^^
474 Repo: https://github.com/maryamtahhan/collectd
475
476 Branch: feat_ipmi_events, feat_ipmi_analog
477
478 Dependencies: OpenIPMI library (http://openipmi.sourceforge.net/)
479
480 The IPMI plugin is already implemented in the latest collectd and sensors
481 like temperature, voltage, fanspeed, current are already supported there.
482 The list of supported IPMI sensors has been extended and sensors like flow,
483 power are supported now. Also, a System Event Log (SEL) notification feature
484 has been introduced.
485
486 * The feat_ipmi_events branch includes new SEL feature support in collectd
487   IPMI plugin. If this feature is enabled, the collectd IPMI plugin will
488   dispatch notifications about new events in System Event Log.
489
490 * The feat_ipmi_analog branch includes the support of extended IPMI sensors in
491   collectd IPMI plugin.
492
493 **Install dependencies**
494
495 On Centos, install OpenIPMI library:
496
497 .. code:: bash
498
499     $ sudo yum install OpenIPMI ipmitool
500
501 Anyway, it's recommended to use the latest version of the OpenIPMI library as
502 it includes fixes of known issues which aren't included in standard OpenIPMI
503 library package. The latest version of the library can be found at
504 https://sourceforge.net/p/openipmi/code/ci/master/tree/. Steps to install the
505 library from sources are described below.
506
507 Remove old version of OpenIPMI library:
508
509 .. code:: bash
510
511     $ sudo yum remove OpenIPMI ipmitool
512
513 Build and install OpenIPMI library:
514
515 .. code:: bash
516
517     $ git clone https://git.code.sf.net/p/openipmi/code openipmi-code
518     $ cd openipmi-code
519     $ autoreconf --install
520     $ ./configure --prefix=/usr
521     $ make
522     $ sudo make install
523
524 Add the directory containing ``OpenIPMI*.pc`` files to the ``PKG_CONFIG_PATH``
525 environment variable:
526
527 .. code:: bash
528
529     export PKG_CONFIG_PATH=/usr/lib/pkgconfig
530
531 Enable IPMI support in the kernel:
532
533 .. code:: bash
534
535     $ sudo modprobe ipmi_devintf
536     $ sudo modprobe ipmi_si
537
538 .. note::
539   If HW supports IPMI, the ``/dev/ipmi0`` character device will be
540   created.
541
542 Clone and install the collectd IPMI plugin:
543
544 .. code:: bash
545
546     $ git clone  https://github.com/maryamtahhan/collectd
547     $ cd collectd
548     $ git checkout $BRANCH
549     $ ./build.sh
550     $ ./configure --enable-syslog --enable-logfile --enable-debug
551     $ make
552     $ sudo make install
553
554 Where $BRANCH is feat_ipmi_events or feat_ipmi_analog.
555
556 This will install collectd to default folder ``/opt/collectd``. The collectd
557 configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``.
558 To configure the IPMI plugin you need to modify the file to include:
559
560 .. code:: bash
561
562     LoadPlugin ipmi
563     <Plugin ipmi>
564        SELEnabled true # only feat_ipmi_events branch supports this
565     </Plugin>
566
567 .. note::
568   By default, IPMI plugin will read all available analog sensor values,
569   dispatch the values to collectd and send SEL notifications.
570
571 For more information on the IPMI plugin parameters and SEL feature configuration,
572 please see:
573 https://github.com/maryamtahhan/collectd/blob/feat_ipmi_events/src/collectd.conf.pod
574
575 Extended analog sensors support doesn't require additional configuration. The usual
576 collectd IPMI documentation can be used:
577
578 - https://collectd.org/wiki/index.php/Plugin:IPMI
579 - https://collectd.org/documentation/manpages/collectd.conf.5.shtml#plugin_ipmi
580
581 IPMI documentation:
582
583 - https://www.kernel.org/doc/Documentation/IPMI.txt
584 - http://www.intel.com/content/www/us/en/servers/ipmi/ipmi-second-gen-interface-spec-v2-rev1-1.html
585
586 Mcelog Plugin
587 ^^^^^^^^^^^^^^
588 Repo: https://github.com/collectd/collectd
589
590 Branch: master
591
592 Dependencies: mcelog
593
594 Start by installing mcelog.
595
596 .. note::
597   The kernel has to have CONFIG_X86_MCE enabled. For 32bit kernels you
598   need atleast a 2.6,30 kernel.
599
600 On Centos:
601
602 .. code:: bash
603
604     $ sudo yum install mcelog
605
606 Or build from source
607
608 .. code:: bash
609
610     $ git clone https://git.kernel.org/pub/scm/utils/cpu/mce/mcelog.git
611     $ cd mcelog
612     $ make
613     ... become root ...
614     $ make install
615     $ cp mcelog.service /etc/systemd/system/
616     $ systemctl enable mcelog.service
617     $ systemctl start mcelog.service
618
619
620 Verify you got a /dev/mcelog. You can verify the daemon is running completely
621 by running:
622
623 .. code:: bash
624
625      $ mcelog --client
626
627 This should query the information in the running daemon. If it prints nothing
628 that is fine (no errors logged yet). More info @
629 http://www.mcelog.org/installation.html
630
631 Modify the mcelog configuration file "/etc/mcelog/mcelog.conf" to include or
632 enable:
633
634 .. code:: bash
635
636     socket-path = /var/run/mcelog-client
637     [dimm]
638     dimm-tracking-enabled = yes
639     dmi-prepopulate = yes
640     uc-error-threshold = 1 / 24h
641     ce-error-threshold = 10 / 24h
642
643     [socket]
644     socket-tracking-enabled = yes
645     mem-uc-error-threshold = 100 / 24h
646     mem-ce-error-threshold = 100 / 24h
647     mem-ce-error-log = yes
648
649     [page]
650     memory-ce-threshold = 10 / 24h
651     memory-ce-log = yes
652     memory-ce-action = soft
653
654     [trigger]
655     children-max = 2
656     directory = /etc/mcelog
657
658
659 Clone and install the collectd mcelog plugin:
660
661 .. code:: bash
662
663     $ git clone  https://github.com/maryamtahhan/collectd
664     $ cd collectd
665     $ ./build.sh
666     $ ./configure --enable-syslog --enable-logfile --enable-debug
667     $ make
668     $ sudo make install
669
670 This will install collectd to default folder ``/opt/collectd``. The collectd
671 configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``.
672 To configure the mcelog plugin you need to modify the configuration file to
673 include:
674
675 .. code:: bash
676
677     <LoadPlugin mcelog>
678       Interval 1
679     </LoadPlugin>
680     <Plugin mcelog>
681        McelogClientSocket "/var/run/mcelog-client"
682     </Plugin>
683
684 For more information on the plugin parameters, please see:
685 https://github.com/maryamtahhan/collectd/blob/feat_ras/src/collectd.conf.pod
686
687 Simulating a Machine Check Exception can be done in one of 3 ways:
688
689 * Running $make test in the mcelog cloned directory - mcelog test suite
690 * using mce-inject
691 * using mce-test
692
693 **mcelog test suite:**
694
695 It is always a good idea to test an error handling mechanism before it is
696 really needed. mcelog includes a test suite. The test suite relies on
697 mce-inject which needs to be installed and in $PATH.
698
699 You also need the mce-inject kernel module configured (with
700 CONFIG_X86_MCE_INJECT=y), compiled, installed and loaded:
701
702 .. code:: bash
703
704     $ modprobe mce-inject
705
706 Then you can run the mcelog test suite with
707
708 .. code:: bash
709
710     $ make test
711
712 This will inject different classes of errors and check that the mcelog triggers
713 runs. There will be some kernel messages about page offlining attempts. The
714 test will also lose a few pages of memory in your system (not significant).
715
716 .. note::
717   This test will kill any running mcelog, which needs to be restarted
718   manually afterwards.
719
720 **mce-inject:**
721
722 A utility to inject corrected, uncorrected and fatal machine check exceptions
723
724 .. code:: bash
725
726     $ git clone https://git.kernel.org/pub/scm/utils/cpu/mce/mce-inject.git
727     $ cd mce-inject
728     $ make
729     $ modprobe mce-inject
730
731 Modify the test/corrected script to include the following:
732
733 .. code:: bash
734
735     CPU 0 BANK 0
736     STATUS 0xcc00008000010090
737     ADDR 0x0010FFFFFFF
738
739 Inject the error:
740 .. code:: bash
741
742     $ ./mce-inject < test/corrected
743
744 .. note::
745   The uncorrected and fatal scripts under test will cause a platform reset.
746   Only the fatal script generates the memory errors**. In order to  quickly
747   emulate uncorrected memory errors and avoid host reboot following test errors
748   from mce-test suite can be injected:
749
750 .. code:: bash
751
752        $ mce-inject  mce-test/cases/coverage/soft-inj/recoverable_ucr/data/srao_mem_scrub
753
754 **mce-test:**
755
756 In addition a more in-depth test of the Linux kernel machine check facilities
757 can be done with the mce-test test suite. mce-test supports testing uncorrected
758 error handling, real error injection, handling of different soft offlining
759 cases, and other tests.
760
761 **Corrected memory error injection:**
762
763 To inject corrected memory errors:
764
765 * Remove sb_edac and edac_core kernel modules: rmmod sb_edac rmmod edac_core
766 * Insert einj module: modprobe einj param_extension=1
767 * Inject an error by specifying details (last command should be repeated at least two times):
768
769 .. code:: bash
770
771     $ APEI_IF=/sys/kernel/debug/apei/einj
772     $ echo 0x8 > $APEI_IF/error_type
773     $ echo 0x01f5591000 > $APEI_IF/param1
774     $ echo 0xfffffffffffff000 > $APEI_IF/param2
775     $ echo 1 > $APEI_IF/notrigger
776     $ echo 1 > $APEI_IF/error_inject
777
778 * Check the MCE statistic: mcelog --client. Check the mcelog log for injected error details: less /var/log/mcelog.
779
780 Open vSwitch Plugins
781 ^^^^^^^^^^^^^^^^^^^^^
782 OvS Plugins Repo: https://github.com/collectd/collectd
783
784 OvS Plugins Branch: master
785
786 OvS Events MIBs: The SNMP OVS interface link status is provided by standard
787 IF-MIB (http://www.net-snmp.org/docs/mibs/IF-MIB.txt)
788
789 Dependencies: Open vSwitch, Yet Another JSON Library (https://github.com/lloyd/yajl)
790
791 On Centos, install the dependencies and Open vSwitch:
792
793 .. code:: bash
794
795     $ sudo yum install yajl-devel
796
797 Steps to install Open vSwtich can be found at
798 http://docs.openvswitch.org/en/latest/intro/install/fedora/
799
800 Start the Open vSwitch service:
801
802 .. code:: bash
803
804     $ sudo service openvswitch-switch start
805
806 Configure the ovsdb-server manager:
807
808 .. code:: bash
809
810     $ sudo ovs-vsctl set-manager ptcp:6640
811
812 Clone and install the collectd ovs plugin:
813
814 .. code:: bash
815
816     $ git clone $REPO
817     $ cd collectd
818     $ git checkout master
819     $ ./build.sh
820     $ ./configure --enable-syslog --enable-logfile --enable-debug
821     $ make
822     $ sudo make install
823
824 This will install collectd to default folder ``/opt/collectd``. The collectd
825 configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``.
826 To configure the OVS events plugin you need to modify the configuration file to include:
827
828 .. code:: bash
829
830     <LoadPlugin ovs_events>
831        Interval 1
832     </LoadPlugin>
833     <Plugin ovs_events>
834        Port "6640"
835        Address "127.0.0.1"
836        Socket "/var/run/openvswitch/db.sock"
837        Interfaces "br0" "veth0"
838        SendNotification true
839     </Plugin>
840
841 To configure the OVS stats plugin you need to modify the configuration file
842 to include:
843
844 .. code:: bash
845
846     <LoadPlugin ovs_stats>
847        Interval 1
848     </LoadPlugin>
849     <Plugin ovs_stats>
850        Port "6640"
851        Address "127.0.0.1"
852        Socket "/var/run/openvswitch/db.sock"
853        Bridges "br0"
854     </Plugin>
855
856 For more information on the plugin parameters, please see:
857 https://github.com/collectd/collectd/blob/master/src/collectd.conf.pod
858
859 OVS PMD stats
860 ^^^^^^^^^^^^^^
861 Repo: https://gerrit.opnfv.org/gerrit/barometer
862
863 Prequistes:
864 1. Open vSwitch dependencies are installed.
865 2. Open vSwitch service is running.
866 3. Ovsdb-server manager is configured.
867 You can refer `Open vSwitch Plugins`_ section above for each one of them.
868
869 OVS PMD stats application is run through the exec plugin.
870
871 To configure the OVS PMD stats application you need to modify the exec plugin configuration
872 to include:
873
874 .. code:: bash
875
876     <LoadPlugin exec>
877        Interval 1
878     </LoadPlugin
879     <Plugin exec>
880         Exec "user:group" "<path to ovs_pmd_stat.sh>"
881     </Plugin>
882
883 .. note:: Exec plugin configuration has to be changed to use appropriate user before starting collectd service.
884
885 ovs_pmd_stat.sh calls the script for OVS PMD stats application with its argument:
886
887 .. code:: bash
888
889      sudo python /usr/local/src/ovs_pmd_stats.py" "--socket-pid-file"
890      "/var/run/openvswitch/ovs-vswitchd.pid"
891
892 SNMP Agent Plugin
893 ^^^^^^^^^^^^^^^^^
894 Repo: https://github.com/maryamtahhan/collectd/
895
896 Branch: master
897
898 Dependencies: NET-SNMP library
899
900 Start by installing net-snmp and dependencies.
901
902 On Centos 7:
903
904 .. code:: bash
905
906     $ sudo yum install net-snmp net-snmp-libs net-snmp-utils net-snmp-devel
907     $ sudo systemctl start snmpd.service
908
909 go to the `snmp configuration`_ steps.
910
911 From source:
912
913 Clone and build net-snmp:
914
915 .. code:: bash
916
917     $ git clone https://github.com/haad/net-snmp.git
918     $ cd net-snmp
919     $ ./configure --with-persistent-directory="/var/net-snmp" --with-systemd --enable-shared --prefix=/usr
920     $ make
921
922 Become root
923
924 .. code:: bash
925
926     $ make install
927
928 Copy default configuration to persistent folder:
929
930 .. code:: bash
931
932     $ cp EXAMPLE.conf /usr/share/snmp/snmpd.conf
933
934 Set library path and default MIB configuration:
935
936 .. code:: bash
937
938     $ cd ~/
939     $ echo export LD_LIBRARY_PATH=/usr/lib >> .bashrc
940     $ net-snmp-config --default-mibdirs
941     $ net-snmp-config --snmpconfpath
942
943 Configure snmpd as a service:
944
945 .. code:: bash
946
947     $ cd net-snmp
948     $ cp ./dist/snmpd.service /etc/systemd/system/
949     $ systemctl enable snmpd.service
950     $ systemctl start snmpd.service
951
952 .. _`snmp configuration`:
953
954 Add the following line to snmpd.conf configuration file
955 ``/etc/snmp/snmpd.conf`` to make all OID tree visible for SNMP clients:
956
957 .. code:: bash
958
959     view    systemview    included   .1
960
961 To verify that SNMP is working you can get IF-MIB table using SNMP client
962 to view the list of Linux interfaces:
963
964 .. code:: bash
965
966     $ snmpwalk -v 2c -c public localhost IF-MIB::interfaces
967
968 Get the default MIB location:
969
970 .. code:: bash
971
972     $ net-snmp-config --default-mibdirs
973     /opt/stack/.snmp/mibs:/usr/share/snmp/mibs
974
975 Install Intel specific MIBs (if needed) into location received by
976 ``net-snmp-config`` command (e.g. ``/usr/share/snmp/mibs``).
977
978 .. code:: bash
979
980     $ git clone https://gerrit.opnfv.org/gerrit/barometer.git
981     $ sudo cp -f barometer/mibs/*.txt /usr/share/snmp/mibs/
982     $ sudo systemctl restart snmpd.service
983
984 Clone and install the collectd snmp_agent plugin:
985
986 .. code:: bash
987
988     $ cd ~
989     $ git clone https://github.com/maryamtahhan/collectd
990     $ cd collectd
991     $ git checkout feat_snmp
992     $ ./build.sh
993     $ ./configure --enable-syslog --enable-logfile --enable-debug --enable-snmp --with-libnetsnmp
994     $ make
995     $ sudo make install
996
997 This will install collectd to default folder ``/opt/collectd``. The collectd
998 configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``.
999
1000 **SNMP Agent plugin is a generic plugin and cannot work without configuration**.
1001 To configure the snmp_agent plugin you need to modify the configuration file to
1002 include OIDs mapped to collectd types. The following example maps scalar
1003 memAvailReal OID to value represented as free memory type of memory plugin:
1004
1005 .. code:: bash
1006
1007     LoadPlugin snmp_agent
1008     <Plugin "snmp_agent">
1009       <Data "memAvailReal">
1010         Plugin "memory"
1011         Type "memory"
1012         TypeInstance "free"
1013         OIDs "1.3.6.1.4.1.2021.4.6.0"
1014       </Data>
1015     </Plugin>
1016
1017
1018 The ``snmpwalk`` command can be used to validate the collectd configuration:
1019
1020 .. code:: bash
1021
1022     $ snmpwalk -v 2c -c public localhost 1.3.6.1.4.1.2021.4.6.0
1023     UCD-SNMP-MIB::memAvailReal.0 = INTEGER: 135237632 kB
1024
1025
1026 **Limitations**
1027
1028 * Object instance with Counter64 type is not supported in SNMPv1. When GetNext
1029   request is received, Counter64 type objects will be skipped. When Get
1030   request is received for Counter64 type object, the error will be returned.
1031 * Interfaces that are not visible to Linux like DPDK interfaces cannot be
1032   retreived using standard IF-MIB tables.
1033
1034 For more information on the plugin parameters, please see:
1035 https://github.com/maryamtahhan/collectd/blob/feat_snmp/src/collectd.conf.pod
1036
1037 For more details on AgentX subagent, please see:
1038 http://www.net-snmp.org/tutorial/tutorial-5/toolkit/demon/
1039
1040 .. _virt-plugin:
1041
1042 virt plugin
1043 ^^^^^^^^^^^^
1044 Repo: https://github.com/maryamtahhan/collectd
1045
1046 Branch: master
1047
1048 Dependencies: libvirt (https://libvirt.org/), libxml2
1049
1050 On Centos, install the dependencies:
1051
1052 .. code:: bash
1053
1054     $ sudo yum install libxml2-dev libpciaccess-devel yajl-devel device-mapper-devel
1055
1056 Install libvirt:
1057
1058 libvirt version in package manager might be quite old and offer only limited
1059 functionality. Hence, building and installing libvirt from sources is recommended.
1060 Detailed instructions can bet found at:
1061 https://libvirt.org/compiling.html
1062
1063 Certain metrics provided by the plugin have a requirement on a minimal version of
1064 the libvirt API. *File system information* statistics require a *Guest Agent (GA)*
1065 to be installed and configured in a VM. User must make sure that installed GA
1066 version supports retrieving file system information. Number of *Performance monitoring events*
1067 metrics depends on running libvirt daemon version.
1068
1069 .. note:: Please keep in mind that RDT metrics (part of *Performance monitoring
1070     events*) have to be supported by hardware. For more details on hardware support,
1071     please see:
1072     https://github.com/01org/intel-cmt-cat
1073
1074     Additionally perf metrics **cannot** be collected if *Intel RDT* plugin is enabled.
1075
1076 libvirt version can be checked with following commands:
1077
1078 .. code:: bash
1079
1080     $ virsh --version
1081     $ libvirtd --version
1082
1083 .. table:: Extended statistics requirements
1084
1085     +-------------------------------+--------------------------+-------------+
1086     | Statistic                     | Min. libvirt API version | Requires GA |
1087     +===============================+==========================+=============+
1088     | Domain reason                 | 0.9.2                    | No          |
1089     +-------------------------------+--------------------------+-------------+
1090     | Disk errors                   | 0.9.10                   | No          |
1091     +-------------------------------+--------------------------+-------------+
1092     | Job statistics                | 1.2.9                    | No          |
1093     +-------------------------------+--------------------------+-------------+
1094     | File system information       | 1.2.11                   | Yes         |
1095     +-------------------------------+--------------------------+-------------+
1096     | Performance monitoring events | 1.3.3                    | No          |
1097     +-------------------------------+--------------------------+-------------+
1098
1099 Start libvirt daemon:
1100
1101 .. code:: bash
1102
1103     $ systemctl start libvirtd
1104
1105 Create domain (VM) XML configuration file. For more information on domain XML
1106 format and examples, please see:
1107 https://libvirt.org/formatdomain.html
1108
1109 .. note:: Installing additional hypervisor dependencies might be required before
1110     deploying virtual machine.
1111
1112 Create domain, based on created XML file:
1113
1114 .. code:: bash
1115
1116     $ virsh define DOMAIN_CFG_FILE.xml
1117
1118 Start domain:
1119
1120 .. code:: bash
1121
1122     $ virsh start DOMAIN_NAME
1123
1124 Check if domain is running:
1125
1126 .. code:: bash
1127
1128     $ virsh list
1129
1130 Check list of available *Performance monitoring events* and their settings:
1131
1132 .. code:: bash
1133
1134     $ virsh perf DOMAIN_NAME
1135
1136 Enable or disable *Performance monitoring events* for domain:
1137
1138 .. code:: bash
1139
1140     $ virsh perf DOMAIN_NAME [--enable | --disable] EVENT_NAME --live
1141
1142 Clone and install the collectd virt plugin:
1143
1144 .. code:: bash
1145
1146     $ git clone $REPO
1147     $ cd collectd
1148     $ ./build.sh
1149     $ ./configure --enable-syslog --enable-logfile --enable-debug
1150     $ make
1151     $ sudo make install
1152
1153 Where ``$REPO`` is equal to information provided above.
1154
1155 This will install collectd to ``/opt/collectd``. The collectd configuration file
1156 ``collectd.conf`` can be found at ``/opt/collectd/etc``.
1157 To load the virt plugin user needs to modify the configuration file to include:
1158
1159 .. code:: bash
1160
1161     LoadPlugin virt
1162
1163 Additionally, user can specify plugin configuration parameters in this file,
1164 such as connection URL, domain name and much more. By default extended virt plugin
1165 statistics are disabled. They can be enabled with ``ExtraStats`` option.
1166
1167 .. code:: bash
1168
1169     <Plugin virt>
1170        RefreshInterval 60
1171        ExtraStats "cpu_util disk disk_err domain_state fs_info job_stats_background pcpu perf vcpupin"
1172     </Plugin>
1173
1174 For more information on the plugin parameters, please see:
1175 https://github.com/maryamtahhan/collectd/blob/feat_libvirt_upstream/src/collectd.conf.pod
1176
1177 .. _install-collectd-as-a-service:
1178
1179 Installing collectd as a service
1180 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
1181 **NOTE**: In an OPNFV installation, collectd is installed and configured as a
1182 service.
1183
1184 Collectd service scripts are available in the collectd/contrib directory.
1185 To install collectd as a service:
1186
1187 .. code:: bash
1188
1189     $ sudo cp contrib/systemd.collectd.service /etc/systemd/system/
1190     $ cd /etc/systemd/system/
1191     $ sudo mv systemd.collectd.service collectd.service
1192     $ sudo chmod +x collectd.service
1193
1194 Modify collectd.service
1195
1196 .. code:: bash
1197
1198     [Service]
1199     ExecStart=/opt/collectd/sbin/collectd
1200     EnvironmentFile=-/opt/collectd/etc/
1201     EnvironmentFile=-/opt/collectd/etc/
1202     CapabilityBoundingSet=CAP_SETUID CAP_SETGID
1203
1204 Reload
1205
1206 .. code:: bash
1207
1208     $ sudo systemctl daemon-reload
1209     $ sudo systemctl start collectd.service
1210     $ sudo systemctl status collectd.service should show success
1211
1212 Additional useful plugins
1213 ^^^^^^^^^^^^^^^^^^^^^^^^^^
1214
1215 **Exec Plugin** : Can be used to show you when notifications are being
1216 generated by calling a bash script that dumps notifications to file. (handy
1217 for debug). Modify /opt/collectd/etc/collectd.conf:
1218
1219 .. code:: bash
1220
1221    LoadPlugin exec
1222    <Plugin exec>
1223    #   Exec "user:group" "/path/to/exec"
1224       NotificationExec "user" "<path to barometer>/barometer/src/collectd/collectd_sample_configs/write_notification.sh"
1225    </Plugin>
1226
1227 write_notification.sh (just writes the notification passed from exec through
1228 STDIN to a file (/tmp/notifications)):
1229
1230 .. code:: bash
1231
1232    #!/bin/bash
1233    rm -f /tmp/notifications
1234    while read x y
1235    do
1236      echo $x$y >> /tmp/notifications
1237    done
1238
1239 output to /tmp/notifications should look like:
1240
1241 .. code:: bash
1242
1243     Severity:WARNING
1244     Time:1479991318.806
1245     Host:localhost
1246     Plugin:ovs_events
1247     PluginInstance:br-ex
1248     Type:gauge
1249     TypeInstance:link_status
1250     uuid:f2aafeec-fa98-4e76-aec5-18ae9fc74589
1251
1252     linkstate of "br-ex" interface has been changed to "DOWN"
1253
1254 * **logfile plugin**: Can be used to log collectd activity. Modify
1255   /opt/collectd/etc/collectd.conf to include:
1256
1257 .. code:: bash
1258
1259     LoadPlugin logfile
1260     <Plugin logfile>
1261         LogLevel info
1262         File "/var/log/collectd.log"
1263         Timestamp true
1264         PrintSeverity false
1265     </Plugin>
1266
1267
1268 Monitoring Interfaces and Openstack Support
1269 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
1270 .. Figure:: monitoring_interfaces.png
1271
1272    Monitoring Interfaces and Openstack Support
1273
1274 The figure above shows the DPDK L2 forwarding application running on a compute
1275 node, sending and receiving traffic. Collectd is also running on this compute
1276 node retrieving the stats periodically from DPDK through the dpdkstat plugin
1277 and publishing the retrieved stats to OpenStack through the
1278 collectd-ceilometer-plugin.
1279
1280 To see this demo in action please checkout: `Barometer OPNFV Summit demo`_
1281
1282 For more information on configuring and installing OpenStack plugins for
1283 collectd, check out the `collectd-ceilometer-plugin GSG`_.
1284
1285 References
1286 ^^^^^^^^^^^
1287 .. [1] https://collectd.org/wiki/index.php/Naming_schema
1288 .. [2] https://github.com/collectd/collectd/blob/master/src/daemon/plugin.h
1289 .. [3] https://collectd.org/wiki/index.php/Value_list_t
1290 .. [4] https://collectd.org/wiki/index.php/Data_set
1291 .. [5] https://collectd.org/documentation/manpages/types.db.5.shtml
1292 .. [6] https://collectd.org/wiki/index.php/Data_source
1293 .. [7] https://collectd.org/wiki/index.php/Meta_Data_Interface
1294
1295 .. _Barometer OPNFV Summit demo: https://prezi.com/kjv6o8ixs6se/software-fastpath-service-quality-metrics-demo/
1296 .. _gnocchi plugin: https://github.com/openstack/collectd-ceilometer-plugin/tree/stable/ocata/
1297 .. _aodh plugin: https://github.com/openstack/collectd-ceilometer-plugin/tree/stable/ocata/
1298 .. _collectd-ceilometer-plugin GSG: https://github.com/openstack/collectd-ceilometer-plugin/blob/master/doc/source/GSG.rst