remove ceph code
[stor4nfv.git] / src / ceph / doc / rbd / iscsi-initiator-esx.rst
diff --git a/src/ceph/doc/rbd/iscsi-initiator-esx.rst b/src/ceph/doc/rbd/iscsi-initiator-esx.rst
deleted file mode 100644 (file)
index 18dd583..0000000
+++ /dev/null
@@ -1,36 +0,0 @@
-----------------------------------
-The iSCSI Initiator for VMware ESX
-----------------------------------
-
-**Prerequisite:**
-
--  VMware ESX 6.0 or later
-
-**iSCSI Discovery and Multipath Device Setup:**
-
-#. From vSphere, open the Storage Adapters, on the Configuration tab. Right click
-   on the iSCSI Software Adapter and select Properties.
-
-#. In the General tab click the "Advanced" button and in the "Advanced Settings"
-   set RecoveryTimeout to 25.
-
-#. If CHAP was setup on the iSCSI gateway, in the General tab click the "CHAP…​"
-   button. If CHAP is not being used, skip to step 4.
-
-#. On the CHAP Credentials windows, select “Do not use CHAP unless required by target”,
-   and enter the "Name" and "Secret" values used on the initial setup for the iSCSI
-   gateway, then click on the "OK" button.
-
-#. On the Dynamic Discovery tab, click the "Add…​" button, and enter the IP address
-   and port of one of the iSCSI target portals. Click on the "OK" button.
-
-#. Close the iSCSI Initiator Properties window. A prompt will ask to rescan the
-   iSCSI software adapter. Select Yes.
-
-#. In the Details pane, the LUN on the iSCSI target will be displayed. Right click
-   on a device and select "Manage Paths".
-
-#. On the Manage Paths window, select “Most Recently Used (VMware)” for the policy
-   path selection. Close and repeat for the other disks.
-
-Now the disks can be used for datastores.