- Troubleshooting Monitors
-=================================
-
-.. index:: monitor, high availability
-
-When a cluster encounters monitor-related troubles there's a tendency to
-panic, and some times with good reason. You should keep in mind that losing
-a monitor, or a bunch of them, don't necessarily mean that your cluster is
-down, as long as a majority is up, running and with a formed quorum.
-Regardless of how bad the situation is, the first thing you should do is to
-calm down, take a breath and try answering our initial troubleshooting script.
-
-
-Initial Troubleshooting
-========================
-
-
-**Are the monitors running?**
-
-  First of all, we need to make sure the monitors are running. You would be
-  amazed by how often people forget to run the monitors, or restart them after
-  an upgrade. There's no shame in that, but let's try not losing a couple of
-  hours chasing an issue that is not there.
-
-**Are you able to connect to the monitor's servers?**
-
-  Doesn't happen often, but sometimes people do have ``iptables`` rules that
-  block accesses to monitor servers or monitor ports. Usually leftovers from
-  monitor stress-testing that were forgotten at some point. Try ssh'ing into
-  the server and, if that succeeds, try connecting to the monitor's port
-  using you tool of choice (telnet, nc,...).
-
-**Does ceph -s run and obtain a reply from the cluster?**
-
-  If the answer is yes then your cluster is up and running.  One thing you
-  can take for granted is that the monitors will only answer to a ``status``
-  request if there is a formed quorum.
-
-  If ``ceph -s`` blocked however, without obtaining a reply from the cluster
-  or showing a lot of ``fault`` messages, then it is likely that your monitors
-  are either down completely or just a portion is up -- a portion that is not
-  enough to form a quorum (keep in mind that a quorum if formed by a majority
-  of monitors).
-
-**What if ceph -s doesn't finish?**
-
-  If you haven't gone through all the steps so far, please go back and do.
-
-  For those running on Emperor 0.72-rc1 and forward, you will be able to
-  contact each monitor individually asking them for their status, regardless
-  of a quorum being formed. This an be achieved using ``ceph ping mon.ID``,
-  ID being the monitor's identifier. You should perform this for each monitor
-  in the cluster. In section `Understanding mon_status`_ we will explain how
-  to interpret the output of this command.
-
-  For the rest of you who don't tread on the bleeding edge, you will need to
-  ssh into the server and use the monitor's admin socket. Please jump to
-  `Using the monitor's admin socket`_.
-
-For other specific issues, keep on reading.
-
-
-Using the monitor's admin socket
-=================================
-
-The admin socket allows you to interact with a given daemon directly using a
-Unix socket file. This file can be found in your monitor's ``run`` directory.
-By default, the admin socket will be kept in ``/var/run/ceph/ceph-mon.ID.asok``
-but this can vary if you defined it otherwise. If you don't find it there,
-please check your ``ceph.conf`` for an alternative path or run::
-
-  ceph-conf --name mon.ID --show-config-value admin_socket
-
-Please bear in mind that the admin socket will only be available while the
-monitor is running. When the monitor is properly shutdown, the admin socket
-will be removed. If however the monitor is not running and the admin socket
-still persists, it is likely that the monitor was improperly shutdown.
-Regardless, if the monitor is not running, you will not be able to use the
-admin socket, with ``ceph`` likely returning ``Error 111: Connection Refused``.
-
-Accessing the admin socket is as simple as telling the ``ceph`` tool to use
-the ``asok`` file.  In pre-Dumpling Ceph, this can be achieved by::
-
-  ceph --admin-daemon /var/run/ceph/ceph-mon.<id>.asok <command>
-
-while in Dumpling and beyond you can use the alternate (and recommended)
-format::
-
-  ceph daemon mon.<id> <command>
-
-Using ``help`` as the command to the ``ceph`` tool will show you the
-supported commands available through the admin socket. Please take a look
-at ``config get``, ``config show``, ``mon_status`` and ``quorum_status``,
-as those can be enlightening when troubleshooting a monitor.
-
-
-Understanding mon_status
-=========================
-
-``mon_status`` can be obtained through the ``ceph`` tool when you have
-a formed quorum, or via the admin socket if you don't. This command will
-output a multitude of information about the monitor, including the same
-output you would get with ``quorum_status``.
-
-Take the following example of ``mon_status``::
-
-  
-  { "name": "c",
-    "rank": 2,
-    "state": "peon",
-    "election_epoch": 38,
-    "quorum": [
-          1,
-          2],
-    "outside_quorum": [],
-    "extra_probe_peers": [],
-    "sync_provider": [],
-    "monmap": { "epoch": 3,
-        "fsid": "5c4e9d53-e2e1-478a-8061-f543f8be4cf8",
-        "modified": "2013-10-30 04:12:01.945629",
-        "created": "2013-10-29 14:14:41.914786",
-        "mons": [
-              { "rank": 0,
-                "name": "a",
-                "addr": "127.0.0.1:6789\/0"},
-              { "rank": 1,
-                "name": "b",
-                "addr": "127.0.0.1:6790\/0"},
-              { "rank": 2,
-                "name": "c",
-                "addr": "127.0.0.1:6795\/0"}]}}
-
-A couple of things are obvious: we have three monitors in the monmap (*a*, *b*
-and *c*), the quorum is formed by only two monitors, and *c* is in the quorum
-as a *peon*.
-
-Which monitor is out of the quorum?
-
-  The answer would be **a**.
-
-Why?
-
-  Take a look at the ``quorum`` set. We have two monitors in this set: *1*
-  and *2*. These are not monitor names. These are monitor ranks, as established
-  in the current monmap. We are missing the monitor with rank 0, and according
-  to the monmap that would be ``mon.a``.
-
-By the way, how are ranks established?
-
-  Ranks are (re)calculated whenever you add or remove monitors and follow a
-  simple rule: the **greater** the ``IP:PORT`` combination, the **lower** the
-  rank is. In this case, considering that ``127.0.0.1:6789`` is lower than all
-  the remaining ``IP:PORT`` combinations, ``mon.a`` has rank 0.
-
-Most Common Monitor Issues
-===========================
-
-Have Quorum but at least one Monitor is down
----------------------------------------------
-
-When this happens, depending on the version of Ceph you are running,
-you should be seeing something similar to::
-
-      $ ceph health detail
-      [snip]
-      mon.a (rank 0) addr 127.0.0.1:6789/0 is down (out of quorum)
-
-How to troubleshoot this?
-
-  First, make sure ``mon.a`` is running.
-
-  Second, make sure you are able to connect to ``mon.a``'s server from the
-  other monitors' servers. Check the ports as well. Check ``iptables`` on
-  all your monitor nodes and make sure you are not dropping/rejecting
-  connections.
-
-  If this initial troubleshooting doesn't solve your problems, then it's
-  time to go deeper.
-
-  First, check the problematic monitor's ``mon_status`` via the admin
-  socket as explained in `Using the monitor's admin socket`_ and
-  `Understanding mon_status`_.
-
-  Considering the monitor is out of the quorum, its state should be one of
-  ``probing``, ``electing`` or ``synchronizing``. If it happens to be either
-  ``leader`` or ``peon``, then the monitor believes to be in quorum, while
-  the remaining cluster is sure it is not; or maybe it got into the quorum
-  while we were troubleshooting the monitor, so check you ``ceph -s`` again
-  just to make sure. Proceed if the monitor is not yet in the quorum.
-
-What if the state is ``probing``?
-
-  This means the monitor is still looking for the other monitors. Every time
-  you start a monitor, the monitor will stay in this state for some time
-  while trying to find the rest of the monitors specified in the ``monmap``.
-  The time a monitor will spend in this state can vary. For instance, when on
-  a single-monitor cluster, the monitor will pass through the probing state
-  almost instantaneously, since there are no other monitors around. On a
-  multi-monitor cluster, the monitors will stay in this state until they
-  find enough monitors to form a quorum -- this means that if you have 2 out
-  of 3 monitors down, the one remaining monitor will stay in this state
-  indefinitively until you bring one of the other monitors up.
-
-  If you have a quorum, however, the monitor should be able to find the
-  remaining monitors pretty fast, as long as they can be reached. If your
-  monitor is stuck probing and you have gone through with all the communication
-  troubleshooting, then there is a fair chance that the monitor is trying
-  to reach the other monitors on a wrong address. ``mon_status`` outputs the
-  ``monmap`` known to the monitor: check if the other monitor's locations
-  match reality. If they don't, jump to
-  `Recovering a Monitor's Broken monmap`_; if they do, then it may be related
-  to severe clock skews amongst the monitor nodes and you should refer to
-  `Clock Skews`_ first, but if that doesn't solve your problem then it is
-  the time to prepare some logs and reach out to the community (please refer
-  to `Preparing your logs`_ on how to best prepare your logs).
-
-
-What if state is ``electing``?
-
-  This means the monitor is in the middle of an election. These should be
-  fast to complete, but at times the monitors can get stuck electing. This
-  is usually a sign of a clock skew among the monitor nodes; jump to
-  `Clock Skews`_ for more infos on that. If all your clocks are properly
-  synchronized, it is best if you prepare some logs and reach out to the
-  community. This is not a state that is likely to persist and aside from
-  (*really*) old bugs there is not an obvious reason besides clock skews on
-  why this would happen.
-
-What if state is ``synchronizing``?
-
-  This means the monitor is synchronizing with the rest of the cluster in
-  order to join the quorum. The synchronization process is as faster as
-  smaller your monitor store is, so if you have a big store it may
-  take a while. Don't worry, it should be finished soon enough.
-
-  However, if you notice that the monitor jumps from ``synchronizing`` to
-  ``electing`` and then back to ``synchronizing``, then you do have a
-  problem: the cluster state is advancing (i.e., generating new maps) way
-  too fast for the synchronization process to keep up. This used to be a
-  thing in early Cuttlefish, but since then the synchronization process was
-  quite refactored and enhanced to avoid just this sort of behavior. If this
-  happens in later versions let us know. And bring some logs
-  (see `Preparing your logs`_).
-
-What if state is ``leader`` or ``peon``?
-
-  This should not happen. There is a chance this might happen however, and
-  it has a lot to do with clock skews -- see `Clock Skews`_. If you are not
-  suffering from clock skews, then please prepare your logs (see
-  `Preparing your logs`_) and reach out to us.
-
-
-Recovering a Monitor's Broken monmap
--------------------------------------
-
-This is how a ``monmap`` usually looks like, depending on the number of
-monitors::
-
-
-      epoch 3
-      fsid 5c4e9d53-e2e1-478a-8061-f543f8be4cf8
-      last_changed 2013-10-30 04:12:01.945629
-      created 2013-10-29 14:14:41.914786
-      0: 127.0.0.1:6789/0 mon.a
-      1: 127.0.0.1:6790/0 mon.b
-      2: 127.0.0.1:6795/0 mon.c
-      
-This may not be what you have however. For instance, in some versions of
-early Cuttlefish there was this one bug that could cause your ``monmap``
-to be nullified.  Completely filled with zeros. This means that not even
-``monmaptool`` would be able to read it because it would find it hard to
-make sense of only-zeros. Some other times, you may end up with a monitor
-with a severely outdated monmap, thus being unable to find the remaining
-monitors (e.g., say ``mon.c`` is down; you add a new monitor ``mon.d``,
-then remove ``mon.a``, then add a new monitor ``mon.e`` and remove
-``mon.b``; you will end up with a totally different monmap from the one
-``mon.c`` knows).
-
-In this sort of situations, you have two possible solutions:
-
-Scrap the monitor and create a new one
-
-  You should only take this route if you are positive that you won't
-  lose the information kept by that monitor; that you have other monitors
-  and that they are running just fine so that your new monitor is able
-  to synchronize from the remaining monitors. Keep in mind that destroying
-  a monitor, if there are no other copies of its contents, may lead to
-  loss of data.
-
-Inject a monmap into the monitor
-
-  Usually the safest path. You should grab the monmap from the remaining
-  monitors and inject it into the monitor with the corrupted/lost monmap.
-
-  These are the basic steps:
-
-  1. Is there a formed quorum? If so, grab the monmap from the quorum::
-
-      $ ceph mon getmap -o /tmp/monmap
-
-  2. No quorum? Grab the monmap directly from another monitor (this
-     assumes the monitor you are grabbing the monmap from has id ID-FOO
-     and has been stopped)::
-
-      $ ceph-mon -i ID-FOO --extract-monmap /tmp/monmap
-
-  3. Stop the monitor you are going to inject the monmap into.
-
-  4. Inject the monmap::
-
-      $ ceph-mon -i ID --inject-monmap /tmp/monmap
-
-  5. Start the monitor
-
-  Please keep in mind that the ability to inject monmaps is a powerful
-  feature that can cause havoc with your monitors if misused as it will
-  overwrite the latest, existing monmap kept by the monitor.
-
-
-Clock Skews
-------------
-
-Monitors can be severely affected by significant clock skews across the
-monitor nodes. This usually translates into weird behavior with no obvious
-cause. To avoid such issues, you should run a clock synchronization tool
-on your monitor nodes.
-
-
-What's the maximum tolerated clock skew?
-
-  By default the monitors will allow clocks to drift up to ``0.05 seconds``.
-
-
-Can I increase the maximum tolerated clock skew?
-
-  This value is configurable via the ``mon-clock-drift-allowed`` option, and
-  although you *CAN* it doesn't mean you *SHOULD*. The clock skew mechanism
-  is in place because clock skewed monitor may not properly behave. We, as
-  developers and QA afficcionados, are comfortable with the current default
-  value, as it will alert the user before the monitors get out hand. Changing
-  this value without testing it first may cause unforeseen effects on the
-  stability of the monitors and overall cluster healthiness, although there is
-  no risk of dataloss.
-
-
-How do I know there's a clock skew?
-
-  The monitors will warn you in the form of a ``HEALTH_WARN``. ``ceph health
-  detail`` should show something in the form of::
-
-      mon.c addr 10.10.0.1:6789/0 clock skew 0.08235s > max 0.05s (latency 0.0045s)
-
-  That means that ``mon.c`` has been flagged as suffering from a clock skew.
-
-
-What should I do if there's a clock skew?
-
-  Synchronize your clocks. Running an NTP client may help. If you are already
-  using one and you hit this sort of issues, check if you are using some NTP
-  server remote to your network and consider hosting your own NTP server on
-  your network.  This last option tends to reduce the amount of issues with
-  monitor clock skews.
-
-
-Client Can't Connect or Mount
-------------------------------
-
-Check your IP tables. Some OS install utilities add a ``REJECT`` rule to
-``iptables``. The rule rejects all clients trying to connect to the host except
-for ``ssh``. If your monitor host's IP tables have such a ``REJECT`` rule in
-place, clients connecting from a separate node will fail to mount with a timeout
-error. You need to address ``iptables`` rules that reject clients trying to
-connect to Ceph daemons.  For example, you would need to address rules that look
-like this appropriately::
-
-       REJECT all -- anywhere anywhere reject-with icmp-host-prohibited
-
-You may also need to add rules to IP tables on your Ceph hosts to ensure
-that clients can access the ports associated with your Ceph monitors (i.e., port
-6789 by default) and Ceph OSDs (i.e., 6800 through 7300 by default). For
-example::
-
-       iptables -A INPUT -m multiport -p tcp -s {ip-address}/{netmask} --dports 6789,6800:7300 -j ACCEPT
-
-Monitor Store Failures
-======================
-
-Symptoms of store corruption
-----------------------------
-
-Ceph monitor stores the `cluster map`_ in a key/value store such as LevelDB. If
-a monitor fails due to the key/value store corruption, following error messages
-might be found in the monitor log::
-
-  Corruption: error in middle of record
-
-or::
-
-  Corruption: 1 missing files; e.g.: /var/lib/ceph/mon/mon.0/store.db/1234567.ldb
-
-Recovery using healthy monitor(s)
----------------------------------
-
-If there is any survivers, we can always `replace`_ the corrupted one with a
-new one. And after booting up, the new joiner will sync up with a healthy
-peer, and once it is fully sync'ed, it will be able to serve the clients.
-
-Recovery using OSDs
--------------------
-
-But what if all monitors fail at the same time? Since users are encouraged to
-deploy at least three monitors in a Ceph cluster, the chance of simultaneous
-failure is rare. But unplanned power-downs in a data center with improperly
-configured disk/fs settings could fail the underlying filesystem, and hence
-kill all the monitors. In this case, we can recover the monitor store with the
-information stored in OSDs.::
-
-  ms=/tmp/mon-store
-  mkdir $ms
-  # collect the cluster map from OSDs
-  for host in $hosts; do
-    rsync -avz $ms user@host:$ms
-    rm -rf $ms
-    ssh user@host <<EOF
-      for osd in /var/lib/osd/osd-*; do
-        ceph-objectstore-tool --data-path \$osd --op update-mon-db --mon-store-path $ms
-      done
-    EOF
-    rsync -avz user@host:$ms $ms
-  done
-  # rebuild the monitor store from the collected map, if the cluster does not
-  # use cephx authentication, we can skip the following steps to update the
-  # keyring with the caps, and there is no need to pass the "--keyring" option.
-  # i.e. just use "ceph-monstore-tool /tmp/mon-store rebuild" instead
-  ceph-authtool /path/to/admin.keyring -n mon. \
-    --cap mon 'allow *'
-  ceph-authtool /path/to/admin.keyring -n client.admin \
-    --cap mon 'allow *' --cap osd 'allow *' --cap mds 'allow *'
-  ceph-monstore-tool /tmp/mon-store rebuild -- --keyring /path/to/admin.keyring
-  # backup corrupted store.db just in case
-  mv /var/lib/ceph/mon/mon.0/store.db /var/lib/ceph/mon/mon.0/store.db.corrupted
-  mv /tmp/mon-store/store.db /var/lib/ceph/mon/mon.0/store.db
-  chown -R ceph:ceph /var/lib/ceph/mon/mon.0/store.db
-
-The steps above
-
-#. collect the map from all OSD hosts,
-#. then rebuild the store,
-#. fill the entities in keyring file with appropriate caps
-#. replace the corrupted store on ``mon.0`` with the recovered copy.
-
-Known limitations
-~~~~~~~~~~~~~~~~~
-
-Following information are not recoverable using the steps above:
-
-- **some added keyrings**: all the OSD keyrings added using ``ceph auth add`` command
-  are recovered from the OSD's copy. And the ``client.admin`` keyring is imported
-  using ``ceph-monstore-tool``. But the MDS keyrings and other keyrings are missing
-  in the recovered monitor store. You might need to re-add them manually.
-
-- **pg settings**: the ``full ratio`` and ``nearfull ratio`` settings configured using
-  ``ceph pg set_full_ratio`` and ``ceph pg set_nearfull_ratio`` will be lost.
-
-- **MDS Maps**: the MDS maps are lost.
-
-
-Everything Failed! Now What?
-=============================
-
-Reaching out for help
-----------------------
-
-You can find us on IRC at #ceph and #ceph-devel at OFTC (server irc.oftc.net)
-and on ``ceph-devel@vger.kernel.org`` and ``ceph-users@lists.ceph.com``. Make
-sure you have grabbed your logs and have them ready if someone asks: the faster
-the interaction and lower the latency in response, the better chances everyone's
-time is optimized.
-
-
-Preparing your logs
----------------------
-
-Monitor logs are, by default, kept in ``/var/log/ceph/ceph-mon.FOO.log*``. We
-may want them. However, your logs may not have the necessary information. If
-you don't find your monitor logs at their default location, you can check
-where they should be by running::
-
-  ceph-conf --name mon.FOO --show-config-value log_file
-
-The amount of information in the logs are subject to the debug levels being
-enforced by your configuration files. If you have not enforced a specific
-debug level then Ceph is using the default levels and your logs may not
-contain important information to track down you issue.
-A first step in getting relevant information into your logs will be to raise
-debug levels. In this case we will be interested in the information from the
-monitor.
-Similarly to what happens on other components, different parts of the monitor
-will output their debug information on different subsystems.
-
-You will have to raise the debug levels of those subsystems more closely
-related to your issue. This may not be an easy task for someone unfamiliar
-with troubleshooting Ceph. For most situations, setting the following options
-on your monitors will be enough to pinpoint a potential source of the issue::
-
-      debug mon = 10
-      debug ms = 1
-
-If we find that these debug levels are not enough, there's a chance we may
-ask you to raise them or even define other debug subsystems to obtain infos
-from -- but at least we started off with some useful information, instead
-of a massively empty log without much to go on with.
-
-Do I need to restart a monitor to adjust debug levels?
-------------------------------------------------------
-
-No. You may do it in one of two ways:
-
-You have quorum
-
-  Either inject the debug option into the monitor you want to debug::
-
-        ceph tell mon.FOO injectargs --debug_mon 10/10
-
-  or into all monitors at once::
-
-        ceph tell mon.* injectargs --debug_mon 10/10
-
-No quourm
-
-  Use the monitor's admin socket and directly adjust the configuration
-  options::
-
-      ceph daemon mon.FOO config set debug_mon 10/10
-
-
-Going back to default values is as easy as rerunning the above commands
-using the debug level ``1/10`` instead.  You can check your current
-values using the admin socket and the following commands::
-
-      ceph daemon mon.FOO config show
-
-or::
-
-      ceph daemon mon.FOO config get 'OPTION_NAME'
-
-
-Reproduced the problem with appropriate debug levels. Now what?
-----------------------------------------------------------------
-
-Ideally you would send us only the relevant portions of your logs.
-We realise that figuring out the corresponding portion may not be the
-easiest of tasks. Therefore, we won't hold it to you if you provide the
-full log, but common sense should be employed. If your log has hundreds
-of thousands of lines, it may get tricky to go through the whole thing,
-specially if we are not aware at which point, whatever your issue is,
-happened. For instance, when reproducing, keep in mind to write down
-current time and date and to extract the relevant portions of your logs
-based on that.
-
-Finally, you should reach out to us on the mailing lists, on IRC or file
-a new issue on the `tracker`_.
-
-.. _cluster map: ../../architecture#cluster-map
-.. _replace: ../operation/add-or-rm-mons
-.. _tracker: http://tracker.ceph.com/projects/ceph/issues/new