From 0910704833646ae7b23e757bb443ed4ad2fe9459 Mon Sep 17 00:00:00 2001
From: Peter Barabas <peter.barabas@ericsson.com>
Date: Thu, 16 Jun 2016 13:51:29 +0200
Subject: [PATCH] Mask ipmitool credentials

Change-Id: I328432e6b30437e8a83065859cd80358d4c3c468
Signed-off-by: Peter Barabas <peter.barabas@ericsson.com>
---
 deploy/dha_adapters/zte_adapter.py | 7 ++++---
 1 file changed, 4 insertions(+), 3 deletions(-)

diff --git a/deploy/dha_adapters/zte_adapter.py b/deploy/dha_adapters/zte_adapter.py
index f6279fbf0..1e610ca41 100644
--- a/deploy/dha_adapters/zte_adapter.py
+++ b/deploy/dha_adapters/zte_adapter.py
@@ -27,14 +27,15 @@ class ZteAdapter(IpmiAdapter):
         WAIT_LOOP = 600
         log('RESET Node %s' % node_id)
         cmd_prefix = self.ipmi_cmd(node_id)
-        state = exec_cmd('%s chassis power status' % cmd_prefix)
+        state = exec_cmd('%s chassis power status' % cmd_prefix, mask_args=[8,10])
         if state == 'Chassis Power is on':
             was_shut_off = False
             done = False
-            exec_cmd('%s chassis power cycle' % cmd_prefix)
+            exec_cmd('%s chassis power cycle' % cmd_prefix, mask_args=[8,10])
             for i in range(WAIT_LOOP):
                 state, _ = exec_cmd('%s chassis power status' % cmd_prefix,
-                                    False)
+                                    check=False,
+                                    mask_args=[8,10])
                 if state == 'Chassis Power is off':
                     was_shut_off = True
                 elif state == 'Chassis Power is on' and was_shut_off:
-- 
2.16.6