Lab documentation for Spirent 72/472/5
authorVictor Laza <vlaza@cloudbasesolutions.com>
Tue, 5 May 2015 07:28:52 +0000 (10:28 +0300)
committerVictor Laza <vlaza@cloudbasesolutions.com>
Mon, 11 May 2015 14:33:40 +0000 (17:33 +0300)
JIRA: PHAROS-12 - Lab documentation for Spirent

Change-Id: I9ea9d02dd502fe70859dafd4edb866d6386a7b56
Signed-off-by: Victor Laza <vlaza@cloudbasesolutions.com>
docs/labs/images/spirent_vptc-public-drawing.png [new file with mode: 0644]
docs/labs/spirent.rst [new file with mode: 0644]

diff --git a/docs/labs/images/spirent_vptc-public-drawing.png b/docs/labs/images/spirent_vptc-public-drawing.png
new file mode 100644 (file)
index 0000000..174ac45
Binary files /dev/null and b/docs/labs/images/spirent_vptc-public-drawing.png differ
diff --git a/docs/labs/spirent.rst b/docs/labs/spirent.rst
new file mode 100644 (file)
index 0000000..4ec987b
--- /dev/null
@@ -0,0 +1,41 @@
+Spirent Virtual Cloud Test Lab
+===============================
+
+A community provided metal resource hosted at Nephoscale, leveraged for SDN/NFV public testing and OpenDaylight, OpenStack, OPNFV projects.
+
+**Spirent VCT Lab** is currently working on 3 different **OpenStack** environments each one of them deployed on different hardware configuration:
+
+  * **OpenStack Juno - 2014.2.2 release** (CentOS 7, 20 Cores, 64 GB RAM, 1 TB SATA, 40 Gbps)
+  * **OpenStack Juno - 2014.2.2 release** (Ubuntu 14.04, 8 cores, 32 GB RAM, 500 GB SATA, 10 Gbps)
+  * **OpenStack Icehouse - 2014.1.3 release**
+  * **OpenStack Icehouse - 2014.1.3 release**
+
+----
+
+There are a number of different networks referenced in the VPTC Design Blueprint.
+
+  * Public Internet – 1 g
+  * Private Management – 1g
+  * Mission Clients – 10g
+  * Mission Servers – 10g
+
+These can be added or removed as specified by the test methodology.
+There are 8 x 10 gige SFP+ ports available on a typical C100MP used for Avalanche Layer 4-7 testing.
+The N4U offers 2 x 40 gige QSFP+ ports with the MX-2 Spirent Test Center Layer 2-3 testing.
+There are 2 x Cumulus switches with 32 ports of 40 gige QSFP+ ports for a total capacity of 256 ports of 10 gige. We use QSFP+ to SFP+ break out cables to convert a single 40 gige port into 4 x 10 gige ports.
+Together these offer a flexible solution to allow up to 8 simultaneous tests to take place with physical traffic generators at the same time.  Assuming a 10 to 1 oversubscription ratio we could handle 80 community users with the current environment.
+For example:
+
+  * An 80 Gbps test would need 4 port pairs of 10 gige each and require 8 mission networks.
+  * Multiple clients sharing common test hardware might have dedicated management networks for their DUTs yet communicate with the APIs and Management services via a shared DMZ network protected by a firewall.
+  * SSL and IPSec VPN will typically be leveraged to connect networks across the untrusted Internet or other third party networks.
+  * Stand-alone DUT servers using STCv and AVv traffic generators could easily scale to hundreds of servers as needed.
+
+.. image:: iamges/spirent_vptc-public-drawing.png
+
+**Documentation tracking**
+
+Revision: _sha1_
+
+Build date:  _date_
+