X-Git-Url: https://gerrit.opnfv.org/gerrit/gitweb?a=blobdiff_plain;f=docs%2Ftesting%2Fuser%2Fuserguide%2Fopnfv_yardstick_tc093.rst;h=4e22e8bf37ff4d476f92148bff2d4ffa5460a37f;hb=HEAD;hp=31fa5d3d329b5b2c4ef42aea246b1a2f9651f97e;hpb=b7f867ba873806a10972108fa19d26b2ae19fa58;p=yardstick.git diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc093.rst b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst index 31fa5d3d3..4e22e8bf3 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc093.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst @@ -43,14 +43,15 @@ Yardstick Test Case Description TC093 +--------------+--------------------------------------------------------------+ |attackers | In this test case, two attackers called “kill-process” are | | | needed. These attackers include three parameters: | -| | 1. fault_type: which is used for finding the attacker's | -| | scripts. It should be set to 'kill-process' in this test | | | | -| | 2. process_name: should be set to the name of the Vswitch | -| | process | +| | 1. fault_type: which is used for finding the attacker's | +| | scripts. It should be set to 'kill-process' in this test | | | | -| | 3. host: which is the name of the compute node where the | -| | Vswitch process is running | +| | 2. process_name: should be set to the name of the Vswitch | +| | process | +| | | +| | 3. host: which is the name of the compute node where the | +| | Vswitch process is running | | | | | | e.g. -fault_type: "kill-process" | | | -process_name: "openvswitch" | @@ -60,16 +61,17 @@ Yardstick Test Case Description TC093 |monitors | This test case utilizes two monitors of type "ip-status" | | | and one monitor of type "process" to track the following | | | conditions: | -| | 1. "ping_same_network_l2": monitor ICMP traffic between | -| | VMs in the same Neutron network | | | | -| | 2. "ping_external_snat": monitor ICMP traffic from VMs to | -| | an external host on the Internet to verify SNAT | -| | functionality. | +| | 1. "ping_same_network_l2": monitor ICMP traffic between | +| | VMs in the same Neutron network | +| | | +| | 2. "ping_external_snat": monitor ICMP traffic from VMs to | +| | an external host on the Internet to verify SNAT | +| | functionality. | | | | -| | 3. "Vswitch process monitor": a monitor checking the | -| | state of the specified Vswitch process. It measures | -| | the recovery time of the given process. | +| | 3. "Vswitch process monitor": a monitor checking the | +| | state of the specified Vswitch process. It measures | +| | the recovery time of the given process. | | | | | | Monitors of type "ip-status" use the "ping" utility to | | | verify reachability of a given target IP. | @@ -99,6 +101,7 @@ Yardstick Test Case Description TC093 +--------------+--------------------------------------------------------------+ |configuration | This test case needs two configuration files: | | | 1. test case file: opnfv_yardstick_tc093.yaml | +| | | | | - Attackers: see above “attackers” description | | | - monitor_time: which is the time (seconds) from | | | starting to stoping the monitors | @@ -173,12 +176,14 @@ Yardstick Test Case Description TC093 |test verdict | This test fails if the SLAs are not met or if there is a | | | test case execution problem. The SLAs are define as follows | | | for this test: | -| | * SDN Vswitch recovery | -| | * process_recover_time <= 30 sec | +| | * SDN Vswitch recovery | +| | | +| | * process_recover_time <= 30 sec | +| | | +| | * no impact on data plane connectivity during SDN | +| | Vswitch failure and recovery. | | | | -| | * no impact on data plane connectivity during SDN | -| | Vswitch failure and recovery. | -| | * packet_drop == 0 | +| | * packet_drop == 0 | | | | +--------------+--------------------------------------------------------------+