+DT bindings for the Renesas R-Mobile System Controller
+
+== System Controller Node ==
+
+The R-Mobile System Controller provides the following functions:
+  - Boot mode management,
+  - Reset generation,
+  - Power management.
+
+Required properties:
+- compatible: Should be "renesas,sysc-<soctype>", "renesas,sysc-rmobile" as
+             fallback.
+             Examples with soctypes are:
+               - "renesas,sysc-r8a73a4" (R-Mobile APE6)
+               - "renesas,sysc-r8a7740" (R-Mobile A1)
+               - "renesas,sysc-sh73a0" (SH-Mobile AG5)
+- reg: Two address start and address range blocks for the device:
+         - The first block refers to the normally accessible registers,
+         - the second block refers to the registers protected by the HPB
+          semaphore.
+
+Optional nodes:
+- pm-domains: This node contains a hierarchy of PM domain nodes, which should
+  match the Power Area Hierarchy in the Power Domain Specifications section of
+  the device's datasheet.
+
+
+== PM Domain Nodes ==
+
+Each of the PM domain nodes represents a PM domain, as documented by the
+generic PM domain bindings in
+Documentation/devicetree/bindings/power/power_domain.txt.
+
+The nodes should be named by the real power area names, and thus their names
+should be unique.
+
+Required properties:
+  - #power-domain-cells: Must be 0.
+
+Optional properties:
+- reg: If the PM domain is not always-on, this property must contain the bit
+       index number for the corresponding power area in the various Power
+       Control and Status Registers. The parent's node must contain the
+       following two properties:
+        - #address-cells: Must be 1,
+        - #size-cells: Must be 0.
+       If the PM domain is always-on, this property must be omitted.
+
+
+Example:
+
+This shows a subset of the r8a7740 PM domain hierarchy, containing the
+C5 "always-on" domain, 2 of its subdomains (A4S and A4SU), and the A3SP domain,
+which is a subdomain of A4S.
+
+       sysc: system-controller@e6180000 {
+               compatible = "renesas,sysc-r8a7740", "renesas,sysc-rmobile";
+               reg = <0xe6180000 0x8000>, <0xe6188000 0x8000>;
+
+               pm-domains {
+                       pd_c5: c5 {
+                               #address-cells = <1>;
+                               #size-cells = <0>;
+                               #power-domain-cells = <0>;
+
+                               pd_a4s: a4s@10 {
+                                       reg = <10>;
+                                       #address-cells = <1>;
+                                       #size-cells = <0>;
+                                       #power-domain-cells = <0>;
+
+                                       pd_a3sp: a3sp@11 {
+                                               reg = <11>;
+                                               #power-domain-cells = <0>;
+                                       };
+                               };
+
+                               pd_a4su: a4su@20 {
+                                       reg = <20>;
+                                       #power-domain-cells = <0>;
+                               };
+                       };
+               };
+       };
+
+
+== PM Domain Consumers ==
+
+Hardware blocks belonging to a PM domain should contain a "power-domains"
+property that is a phandle pointing to the corresponding PM domain node.
+
+Example:
+
+       tpu: pwm@e6600000 {
+               compatible = "renesas,tpu-r8a7740", "renesas,tpu";
+               reg = <0xe6600000 0x100>;
+               clocks = <&mstp3_clks R8A7740_CLK_TPU0>;
+               power-domains = <&pd_a3sp>;
+               #pwm-cells = <3>;
+       };