set -o pipefail
IPV6_FLAG=False
+ALLINONE_FLAG=False
+CSIT_ENV_FLAG=False
# log info to console
echo "Starting the Apex deployment."
# we want to use that built in mechanism to avoid re-downloading every job
# so we use a dedicated folder to hold the upstream cache
UPSTREAM_CACHE=$HOME/upstream_cache
- if [ "$BRANCH" == 'master' ]; then
+ if [[ "$BRANCH" != 'stable/fraser' ]]; then
mkdir -p ${UPSTREAM_CACHE}
RESOURCES=$UPSTREAM_CACHE
else
# set to use different directory here because upon RPM removal this
# directory will be wiped in daily
UPSTREAM_CACHE=$HOME/upstream_cache
- if [ "$BRANCH" == 'master' ]; then
+ if [[ "$BRANCH" != 'stable/fraser' ]]; then
mkdir -p ${UPSTREAM_CACHE}
RESOURCES=$UPSTREAM_CACHE
else
sudo ${CLEAN_CMD} ${clean_opts}
fi
+# These are add-ons to regular scenarios where you can do like
+# os-nosdn-nofeature-noha-ipv6, or os-nosdn-nofeature-noha-allinone
if echo ${DEPLOY_SCENARIO} | grep ipv6; then
IPV6_FLAG=True
DEPLOY_SCENARIO=$(echo ${DEPLOY_SCENARIO} | sed 's/-ipv6//')
echo "INFO: IPV6 Enabled"
fi
+if echo ${DEPLOY_SCENARIO} | grep allinone; then
+ ALLINONE_FLAG=True
+ DEPLOY_SCENARIO=$(echo ${DEPLOY_SCENARIO} | sed 's/-allinone//')
+ echo "INFO: All in one deployment detected"
+fi
+
+if echo ${DEPLOY_SCENARIO} | grep csit; then
+ CSIT_ENV_FLAG=True
+ DEPLOY_SCENARIO=$(echo ${DEPLOY_SCENARIO} | sed 's/-csit//')
+ echo "INFO: CSIT env requested in deploy scenario"
+fi
+
echo "Deploy Scenario set to ${DEPLOY_SCENARIO}"
DEPLOY_FILE="${DEPLOY_SETTINGS_DIR}/${DEPLOY_SCENARIO}.yaml"
if [[ "${DEPLOY_SCENARIO}" =~ fdio|ovs ]]; then
DEPLOY_CMD="${DEPLOY_CMD} --virtual-default-ram 12 --virtual-compute-ram 7"
fi
- if [[ "$PROMOTE" == "True" ]]; then
- DEPLOY_CMD="${DEPLOY_CMD} --virtual-computes 2 -e csit-environment.yaml"
+ if [[ "$ALLINONE_FLAG" == "True" ]]; then
+ DEPLOY_CMD="${DEPLOY_CMD} --virtual-computes 0"
+ elif [[ "$PROMOTE" == "True" ]]; then
+ DEPLOY_CMD="${DEPLOY_CMD} --virtual-computes 2"
+ fi
+
+ if [[ "$PROMOTE" == "True" || "$CSIT_ENV_FLAG" == "True" ]]; then
+ if [[ "$OS_VERSION" != "master" ]]; then
+ CSIT_ENV="csit-${OS_VERSION}-environment.yaml"
+ else
+ CSIT_ENV="csit-environment.yaml"
+ fi
+ DEPLOY_CMD="${DEPLOY_CMD} -e ${CSIT_ENV}"
fi
else
# settings for bare metal deployment
DEPLOY_CMD="${DEPLOY_CMD} -i ${INVENTORY_FILE}"
fi
-if [[ "$BRANCH" == "master" ]]; then
- echo "Upstream deployment detected"
- DEPLOY_CMD="${DEPLOY_CMD} --upstream"
-fi
-
if [ "$IPV6_FLAG" == "True" ]; then
NETWORK_FILE="${NETWORK_SETTINGS_DIR}/network_settings_v6.yaml"
elif [[ "$PROMOTE" == "True" ]]; then