.. http://creativecommons.org/licenses/by/4.0
-===========================================
-Test Results for apex-os-nosdn-nofeature-ha
-===========================================
+================================
+Test Results for os-nosdn-kvm-ha
+================================
.. toctree::
:maxdepth: 2
-Details
-=======
+fuel
+====
.. _Grafana: http://testresults.opnfv.org/grafana/dashboard/db/yardstick-main
-.. _POD1: https://wiki.opnfv.org/pharos?&#community_test_labs
-
+.. _POD2: https://wiki.opnfv.org/pharos?&#community_test_labs
Overview of test results
------------------------
on the details of each run test scenario as well.
All of the test case results below are based on 4 scenario test
-runs, each run on the LF POD1_ between August 25 and 28 in
+runs, each run on the Ericsson POD2_ or LF POD2_ between August 24 and 30 in
2016.
TC002
-----
The round-trip-time (RTT) between 2 VMs on different blades is measured using
-ping. Most test run measurements result on average between 0.74 and 1.08 ms.
-A few runs start with a 0.99 - 1.07 ms RTT spike (This could be because of
-normal ARP handling). One test run has a greater RTT spike of 1.35 ms.
+ping. Most test run measurements result on average between 0.44 and 0.75 ms.
+A few runs start with a 0.65 - 0.68 ms RTT spike (This could be because of
+normal ARP handling). One test run has a greater RTT spike of 1.49 ms.
To be able to draw conclusions more runs should be made. SLA set to 10 ms.
The SLA value is used as a reference, it has not been defined by OPNFV.
TC005
-----
The IO read bandwidth looks similar between different dates, with an
-average between approx. 128 and 136 MB/s. Within each test run the results
-vary, with a minimum 5 MB/s and maximum 446 MB/s on the totality. Most runs
-have a minimum BW of 5 MB/s (one run at 6 MB/s). The maximum BW varies more in
-absolute numbers between the dates, between 416 and 446 MB/s.
+average between approx. 92 and 204 MB/s. Within each test run the results
+vary, with a minimum 2 MB/s and maximum 819 MB/s on the totality. Most runs
+have a minimum BW of 3 MB/s (one run at 2 MB/s). The maximum BW varies more in
+absolute numbers between the dates, between 238 and 819 MB/s.
SLA set to 400 MB/s. The SLA value is used as a reference, it has not been
defined by OPNFV.
TC010
-----
The measurements for memory latency are similar between test dates and result
-in approx. 1.09 ns. The variations within each test run are similar, between
-1.0860 and 1.0880 ns.
+in approx. 2.07 ns. The variations within each test run are similar, between
+1.41 and 3.53 ns.
SLA set to 30 ns. The SLA value is used as a reference, it has not been defined
by OPNFV.
TC011
-----
Packet delay variation between 2 VMs on different blades is measured using
-Iperf3. The reported packet delay variation varies between 0.0025 and 0.0148 ms,
-with an average delay variation between 0.0056 ms and 0.0157 ms.
+Iperf3. The reported packet delay variation varies between 0.0051 and 0.0243 ms,
+with an average delay variation between 0.0081 ms and 0.0195 ms.
TC012
-----
Between test dates, the average measurements for memory bandwidth result in
-approx. 19.70 GB/s. Within each test run the results vary more, with a minimal
-BW of 18.16 GB/s and maximum of 20.13 GB/s on the totality.
+approx. 13.6 GB/s. Within each test run the results vary more, with a minimal
+BW of 6.09 GB/s and maximum of 16.47 GB/s on the totality.
SLA set to 15 GB/s. The SLA value is used as a reference, it has not been
defined by OPNFV.
TC014
-----
-The Unixbench processor test run results vary between scores 3224.4 and 3842.8,
-one result each date. The average score on the total is 3659.5.
+The Unixbench processor test run results vary between scores 2316 and 3619,
+one result each date.
No SLA set.
TC037
appears around 7%.
TC069
+-----
Between test dates, the average measurements for memory bandwidth vary between
22.6 and 29.1 GB/s. Within each test run the results vary more, with a minimal
BW of 20.0 GB/s and maximum of 29.5 GB/s on the totality.
TC070
+-----
The amount of packets per second (PPS) and round trip times (RTT) between 2 VMs
on different blades are measured when increasing the amount of UDP flows sent
between the VMs using pktgen as packet generator tool.
around 340MB.
TC071
+-----
The amount of packets per second (PPS) and round trip times (RTT) between 2 VMs
on different blades are measured when increasing the amount of UDP flows sent
between the VMs using pktgen as packet generator tool.
utilization vary between 205MB to 212MB.
TC072
+-----
The amount of packets per second (PPS) and round trip times (RTT) between 2 VMs
on different blades are measured when increasing the amount of UDP flows sent
between the VMs using pktgen as packet generator tool.
Detailed test results
---------------------
-The scenario was run on LF POD1_ with:
-Apex
+The scenario was run on Ericsson POD2_ and LF POD2_ with:
+Fuel 9.0
OpenStack Mitaka
OpenVirtualSwitch 2.5.90
OpenDayLight Beryllium