@@ -1,129 +0,0 @@
-.. This work is licensed under a Creative Commons Attribution 4.0 International License.
-.. http://creativecommons.org/licenses/by/4.0
-
-.. _nfvi_faults:
-
-Annex: NFVI Faults
-=================================================
-
-Faults in the listed elements need to be immediately notified to the Consumer in
-order to perform an immediate action like live migration or switch to a hot
-standby entity. In addition, the Administrator of the host should trigger a
-maintenance action to, e.g., reboot the server or replace a defective hardware
-element.
-
-Faults can be of different severity, i.e., critical, warning, or
-info. Critical faults require immediate action as a severe degradation of the
-system has happened or is expected. Warnings indicate that the system
-performance is going down: related actions include closer (e.g. more frequent)
-monitoring of that part of the system or preparation for a cold migration to a
-backup VM. Info messages do not require any action. We also consider a type
-"maintenance", which is no real fault, but may trigger maintenance actions
-like a re-boot of the server or replacement of a faulty, but redundant HW.
-
-Faults can be gathered by, e.g., enabling SNMP and installing some open source
-tools to catch and poll SNMP. When using for example Zabbix one can also put an
-agent running on the hosts to catch any other fault. In any case of failure, the
-Administrator should be notified. The following tables provide a list of high
-level faults that are considered within the scope of the Doctor project
-requiring immediate action by the Consumer.
-
-**Compute/Storage**
-
-+-------------------+----------+------------+-----------------+------------------+
-| Fault             | Severity | How to     | Comment         | Immediate action |
-|                   |          | detect?    |                 | to recover       |
-+===================+==========+============+=================+==================+
-| Processor/CPU     | Critical | Zabbix     |                 | Switch to hot    |
-| failure, CPU      |          |            |                 | standby          |
-| condition not ok  |          |            |                 |                  |
-+-------------------+----------+------------+-----------------+------------------+
-| Memory failure/   | Critical | Zabbix     |                 | Switch to hot    |
-| Memory condition  |          | (IPMI)     |                 | standby          |
-| not ok            |          |            |                 |                  |
-+-------------------+----------+------------+-----------------+------------------+
-| Network card      | Critical | Zabbix/    |                 | Switch to hot    |
-| failure, e.g.     |          | Ceilometer |                 | standby          |
-| network adapter   |          |            |                 |                  |
-| connectivity lost |          |            |                 |                  |
-+-------------------+----------+------------+-----------------+------------------+
-| Disk crash        | Info     | RAID       | Network storage | Inform OAM       |
-|                   |          | monitoring | is very         |                  |
-|                   |          |            | redundant (e.g. |                  |
-|                   |          |            | RAID system)    |                  |
-|                   |          |            | and can         |                  |
-|                   |          |            | guarantee high  |                  |
-|                   |          |            | availability    |                  |
-+-------------------+----------+------------+-----------------+------------------+
-| Storage           | Critical | Zabbix     |                 | Live migration   |
-| controller        |          | (IPMI)     |                 | if storage       |
-|                   |          |            |                 | is still         |
-|                   |          |            |                 | accessible;      |
-|                   |          |            |                 | otherwise hot    |
-|                   |          |            |                 | standby          |
-+-------------------+----------+------------+-----------------+------------------+
-| PDU/power         | Critical | Zabbix/    |                 | Switch to hot    |
-| failure, power    |          | Ceilometer |                 | standby          |
-| off, server reset |          |            |                 |                  |
-+-------------------+----------+------------+-----------------+------------------+
-| Power             | Warning  | SNMP       |                 | Live migration   |
-| degration, power  |          |            |                 |                  |
-| redundancy lost,  |          |            |                 |                  |
-| power threshold   |          |            |                 |                  |
-| exceeded          |          |            |                 |                  |
-+-------------------+----------+------------+-----------------+------------------+
-| Chassis problem   | Warning  | SNMP       |                 | Live migration   |
-| (e.g. fan         |          |            |                 |                  |
-| degraded/failed,  |          |            |                 |                  |
-| chassis power     |          |            |                 |                  |
-| degraded), CPU    |          |            |                 |                  |
-| fan problem,      |          |            |                 |                  |
-| temperature/      |          |            |                 |                  |
-| thermal condition |          |            |                 |                  |
-| not ok            |          |            |                 |                  |
-+-------------------+----------+------------+-----------------+------------------+
-| Mainboard failure | Critical | Zabbix     | e.g. PCIe, SAS  | Switch to hot    |
-|                   |          | (IPMI)     | link failure    | standby          |
-+-------------------+----------+------------+-----------------+------------------+
-| OS crash (e.g.    | Critical | Zabbix     |                 | Switch to hot    |
-| kernel panic)     |          |            |                 | standby          |
-+-------------------+----------+------------+-----------------+------------------+
-
-**Hypervisor**
-
-+----------------+----------+------------+-------------+-------------------+
-| Fault          | Severity | How to     | Comment     | Immediate action  |
-|                |          | detect?    |             | to recover        |
-+================+==========+============+=============+===================+
-| System has     | Critical | Zabbix     |             | Switch to hot     |
-| restarted      |          |            |             | standby           |
-+----------------+----------+------------+-------------+-------------------+
-| Hypervisor     | Warning/ | Zabbix/    |             | Evacuation/switch |
-| failure        | Critical | Ceilometer |             | to hot standby    |
-+----------------+----------+------------+-------------+-------------------+
-| Hypervisor     | Warning  | Alarming   | Zabbix/     | Rebuild VM        |
-| status not     |          | service    | Ceilometer  |                   |
-| retrievable    |          |            | unreachable |                   |
-| after certain  |          |            |             |                   |
-| period         |          |            |             |                   |
-+----------------+----------+------------+-------------+-------------------+
-
-**Network**
-
-+------------------+----------+---------+----------------+---------------------+
-| Fault            | Severity | How to  | Comment        | Immediate action to |
-|                  |          | detect? |                | recover             |
-+==================+==========+=========+================+=====================+
-| SDN/OpenFlow     | Critical | Ceilo-  |                | Switch to           |
-| switch,          |          | meter   |                | hot standby         |
-| controller       |          |         |                | or reconfigure      |
-| degraded/failed  |          |         |                | virtual network     |
-|                  |          |         |                | topology            |
-+------------------+----------+---------+----------------+---------------------+
-| Hardware failure | Warning  | SNMP    | Redundancy of  | Live migration if   |
-| of physical      |          |         | physical       | possible otherwise  |
-| switch/router    |          |         | infrastructure | evacuation          |
-|                  |          |         | is reduced or  |                     |
-|                  |          |         | no longer      |                     |
-|                  |          |         | available      |                     |
-+------------------+----------+---------+----------------+---------------------+