-Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers
-for the use of OPNFV community as part of the OPNFV Pharos Project
+Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal
+servers for the use of OPNFV community as part of the OPNFV Pharos Project
 
 
 The Dell Testlab consists of 2 PODs
@@ -34,40 +34,40 @@ following specifications:
 POD1-Fuel
 ^^^^^^^^^
 
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Hostname            |  Model               | Memory         | Storage      | Processor           | Socket     |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Fuel Jump Server    |  Dell PowerEdge M620 | 64 GB          | 1200GB HDD   | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node2               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node3               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node4               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node5               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node6               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
++------------------+----------------------+--------+------------+---------------------+--------+
+| Hostname         |  Model               | Memory | Storage    | Processor           | Socket |
++------------------+----------------------+--------+------------+---------------------+--------+
+| Fuel Jump Server |  Dell PowerEdge M620 | 64 GB  | 1200GB HDD | Intel  Xeon E5-2640 |   2    |
++------------------+----------------------+--------+------------+---------------------+--------+
+| Node2            |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++------------------+----------------------+--------+------------+---------------------+--------+
+| Node3            |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++------------------+----------------------+--------+------------+---------------------+--------+
+| Node4            |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++------------------+----------------------+--------+------------+---------------------+--------+
+| Node5            |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++------------------+----------------------+--------+------------+---------------------+--------+
+| Node6            |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++------------------+----------------------+--------+------------+---------------------+--------+
 
 POD2-Foreman
 ^^^^^^^^^^^^
 
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Hostname            |  Model               |    Memory      | Storage      | Processor           | Socket     |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Foreman Jump Server |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node7               |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node8               |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node9               |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node11              |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node12              |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
++---------------------+----------------------+-----------+-----------+---------------------+--------+
+| Hostname            |  Model               |    Memory | Storage   | Processor           | Socket |
++---------------------+----------------------+-----------+-----------+---------------------+--------+
+| Foreman Jump Server |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++---------------------+----------------------+-----------+-----------+---------------------+--------+
+| Node7               |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++---------------------+----------------------+-----------+-----------+---------------------+--------+
+| Node8               |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++---------------------+----------------------+-----------+-----------+---------------------+--------+
+| Node9               |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++---------------------+----------------------+-----------+-----------+---------------------+--------+
+| Node11              |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++---------------------+----------------------+-----------+-----------+---------------------+--------+
+| Node12              |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++---------------------+----------------------+-----------+-----------+---------------------+--------+
 
 Software
 ---------
@@ -94,81 +94,81 @@ POD1-Fuel
    :alt: POD1-Fuel Overview
    :align: left
 
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Hostname            |  NIC Model                                   | Ports|MAC                | BW    | Roles                            |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Fuel Jump           |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:81 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:84 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:85 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:87 | 10G   | Fuel Admin/mgmt/pvt/ storage     |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:89 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:8B | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node2               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:8E | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:91 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:92 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:94 | 10G   | Fuel Admin/mgmt/pvt/ storage     |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:96 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:98 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node3               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:9B | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:9E | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:9F | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:A1 | 10G   | Fuel Admin/mgmt/pvt/ storage     |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:A3 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:A5 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node4               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:A8 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:AB | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:AC | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:AE | 10G   | Fuel Admin/mgmt/pvt/ storage     |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:B0 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:B1 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node5               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:B5 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:B8 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:B9 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:BB | 10G   | Fuel Admin/mgmt/pvt/ storage     |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Broadcom  NetXtreme II BCM57810          | p1p1 | A4:1F:72:11:B4:BD | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:C0 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node6               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:C2 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:C5 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:C6 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:C8 | 10G   | Fuel Admin/mgmt/pvt/ storage     |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Broadcom  NetXtreme II BCM57810          | p1p1 | A4:1F:72:11:B4:CA | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:CD | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+| Hostname  |  NIC Model                          | Ports | MAC               | BW  | Roles                        |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+| Fuel Jump |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:81 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | em2   | A4:1F:72:11:B4:84 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:85 | 10G | Public                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p3p2  | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  3, Intel  82599                    | p1p1  | A4:1F:72:11:B4:89 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p1p2  | A4:1F:72:11:B4:8B | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+| Node2     |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:8E | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | em2   | A4:1F:72:11:B4:91 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:92 | 10G | Public                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p3p2  | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  3, Intel  82599                    | p1p1  | A4:1F:72:11:B4:96 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p1p2  | A4:1F:72:11:B4:98 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+| Node3     |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:9B | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | em2   | A4:1F:72:11:B4:9E | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:9F | 10G | Public                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p3p2  | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  3, Intel  82599                    | p1p1  | A4:1F:72:11:B4:A3 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p1p2  | A4:1F:72:11:B4:A5 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+| Node4     |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:A8 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | em2   | A4:1F:72:11:B4:AB | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:AC | 10G | Public                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p3p2  | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  3, Intel  82599                    | p1p1  | A4:1F:72:11:B4:B0 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p1p2  | A4:1F:72:11:B4:B1 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+| Node5     |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:B5 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | em2   | A4:1F:72:11:B4:B8 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:B9 | 10G | Public                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p3p2  | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  3, Broadcom  NetXtreme II BCM57810 | p1p1  | A4:1F:72:11:B4:BD | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p1p2  | A4:1F:72:11:B4:C0 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+| Node6     |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:C2 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | em2   | A4:1F:72:11:B4:C5 | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:C6 | 10G | Public                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p3p2  | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |  3, Broadcom  NetXtreme II BCM57810 | p1p1  | A4:1F:72:11:B4:CA | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
+|           |                                     | p1p2  | A4:1F:72:11:B4:CD | 10G | Unused                       |
++-----------+-------------------------------------+-------+-------------------+-----+------------------------------+
 
 
 
@@ -182,104 +182,104 @@ POD2-Foreman
    :align: left
 
 
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Hostname            |  NIC Model                                   | Ports|MAC                | BW    | Roles                            |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Foreman Jump        |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B5:1D | 10G   | Foreman Admin                    |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B5:20 | 10G   | Foreman Private/ Storage         |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B5:21 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B5:23 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, TBD                                      | p1p1 | A4:1F:72:11:B4:89 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:8B | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node7               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:CF | 10G   | Foreman Admin                    |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:D2 | 10G   | Foreman Private/ Storage         |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:D3 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:D5 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3,  Broadcom  NetXtreme II BCM57810         | p1p1 | A4:1F:72:11:B4:D7 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:DA | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node8               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:DC | 10G   | Foreman Admin                    |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:DF | 10G   | Foreman Private/ Storage         |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:E0 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:E2 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Broadcom  NetXtreme II BCM57810          | p1p1 | A4:1F:72:11:B4:E4 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:E7 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node9               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:E9 | 10G   | Foreman Admin                    |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:EC | 10G   | Foreman Private/ Storage         |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:ED | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:EF | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:F1 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:F3 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node11              |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B5:03 | 10G   | Foreman Admin                    |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B5:06 | 10G   | Foreman Private/ Storage         |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B5:07 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B5:09 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B5:0B | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B5:0D | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node12              |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B5:10 | 10G   | Foreman Admin                    |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B5:13 | 10G   | Foreman Private/ Storage         |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B5:14 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B5:16 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, TBD                                      | p1p1 | A4:1F:72:11:B4:89 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:8B | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+| Hostname     |  NIC Model                           | Ports | MAC               | BW  | Roles                    |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+| Foreman Jump |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B5:1D | 10G | Foreman Admin            |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | em2   | A4:1F:72:11:B5:20 | 10G | Foreman Private/ Storage |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B5:21 | 10G | Public                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B5:23 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  3, TBD                              | p1p1  | A4:1F:72:11:B4:89 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:8B | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+| Node7        |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B4:CF | 10G | Foreman Admin            |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | em2   | A4:1F:72:11:B4:D2 | 10G | Foreman Private/ Storage |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B4:D3 | 10G | Public                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B4:D5 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  3,  Broadcom  NetXtreme II BCM57810 | p1p1  | A4:1F:72:11:B4:D7 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:DA | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+| Node8        |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B4:DC | 10G | Foreman Admin            |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | em2   | A4:1F:72:11:B4:DF | 10G | Foreman Private/ Storage |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B4:E0 | 10G | Public                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B4:E2 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  3, Broadcom  NetXtreme II BCM57810  | p1p1  | A4:1F:72:11:B4:E4 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:E7 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+| Node9        |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B4:E9 | 10G | Foreman Admin            |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | em2   | A4:1F:72:11:B4:EC | 10G | Foreman Private/ Storage |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B4:ED | 10G | Public                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B4:EF | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  3, Intel  82599                     | p1p1  | A4:1F:72:11:B4:F1 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:F3 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+| Node11       |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B5:03 | 10G | Foreman Admin            |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | em2   | A4:1F:72:11:B5:06 | 10G | Foreman Private/ Storage |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B5:07 | 10G | Public                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B5:09 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  3, Intel  82599                     | p1p1  | A4:1F:72:11:B5:0B | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B5:0D | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+| Node12       |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B5:10 | 10G | Foreman Admin            |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | em2   | A4:1F:72:11:B5:13 | 10G | Foreman Private/ Storage |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B5:14 | 10G | Public                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B5:16 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |  3, TBD                              | p1p1  | A4:1F:72:11:B4:89 | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:8B | 10G | Unused                   |
++--------------+--------------------------------------+-------+-------------------+-----+--------------------------+
 
 Subnet allocations
 ^^^^^^^^^^^^^^^^^^
 
-+-------------------+----------------+-------------------+---------------+----------+
-| Network name      | Address        | Mask              | Gateway       | VLAN id  |
-+-------------------+----------------+-------------------+---------------+----------+
-| Fuel Admin        | 10.20.0.0      |  255.255.0.0      | 10.20.0.1     | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Fuel Mangement    | 192.168.0.0    |  255.255.255.0    | 192.168.0.1   | 101      |
-+-------------------+----------------+-------------------+---------------+----------+
-| Fuel Storage      | 192.168.1.0    |  255.255.255.0    | 192.168.1.1   | 102      |
-+-------------------+----------------+-------------------+---------------+----------+
-| Fuel Public       | 172.18.0.64    |  255.255.255.192  | 172.18.0.65   | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Foreman  Admin    | 10.4.14.0      |  255.255.255.0    | 10.4.14.100   | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Foreman Private   | 10.4.5.0       |  255.255.255.0    | 10.4.5.1      | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Foreman Public    | 172.18.0.0     |  255.255.255.192  | 172.18.0.1    | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Lights Out        | 172.18.0.128   |  255.255.255.128  | 172.18.0.129  | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
++-----------------+--------------+------------------+--------------+----------+
+| Network name    | Address      | Mask             | Gateway      | VLAN id  |
++-----------------+--------------+------------------+--------------+----------+
+| Fuel Admin      | 10.20.0.0    |  255.255.0.0     | 10.20.0.1    | Untagged |
++-----------------+--------------+------------------+--------------+----------+
+| Fuel Mangement  | 192.168.0.0  |  255.255.255.0   | 192.168.0.1  | 101      |
++-----------------+--------------+------------------+--------------+----------+
+| Fuel Storage    | 192.168.1.0  |  255.255.255.0   | 192.168.1.1  | 102      |
++-----------------+--------------+------------------+--------------+----------+
+| Fuel Public     | 172.18.0.64  |  255.255.255.192 | 172.18.0.65  | Untagged |
++-----------------+--------------+------------------+--------------+----------+
+| Foreman  Admin  | 10.4.14.0    |  255.255.255.0   | 10.4.14.100  | Untagged |
++-----------------+--------------+------------------+--------------+----------+
+| Foreman Private | 10.4.5.0     |  255.255.255.0   | 10.4.5.1     | Untagged |
++-----------------+--------------+------------------+--------------+----------+
+| Foreman Public  | 172.18.0.0   |  255.255.255.192 | 172.18.0.1   | Untagged |
++-----------------+--------------+------------------+--------------+----------+
+| Lights Out      | 172.18.0.128 |  255.255.255.128 | 172.18.0.129 | Untagged |
++-----------------+--------------+------------------+--------------+----------+
 
 
 Lights out Network
@@ -287,39 +287,39 @@ Lights out Network
 
 **POD1**
 
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Hostname       | Lights-out address            | MAC              |    Username         | Password            |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Fuel-Jump      | 172.18.1.131                  | A4:1F:72:11:B4:80|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node2          | 172.18.1.132                  | A4:1F:72:11:B4:8D|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node3          | 172.18.1.133                  | A4:1F:72:11:B4:9A|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node4          | 172.18.1.134                  | A4:1F:72:11:B4:A7|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node5          | 172.18.1.135                  | A4:1F:72:11:B4:B4|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node6          | 172.18.1.136                  | A4:1F:72:11:B4:C1|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
++-----------+--------------------+-------------------+-------------+-------------+
+| Hostname  | Lights-out address | MAC               |    Username | Password    |
++-----------+--------------------+-------------------+-------------+-------------+
+| Fuel-Jump | 172.18.1.131       | A4:1F:72:11:B4:80 |      root   |      calvin |
++-----------+--------------------+-------------------+-------------+-------------+
+| Node2     | 172.18.1.132       | A4:1F:72:11:B4:8D |      root   |      calvin |
++-----------+--------------------+-------------------+-------------+-------------+
+| Node3     | 172.18.1.133       | A4:1F:72:11:B4:9A |      root   |      calvin |
++-----------+--------------------+-------------------+-------------+-------------+
+| Node4     | 172.18.1.134       | A4:1F:72:11:B4:A7 |      root   |      calvin |
++-----------+--------------------+-------------------+-------------+-------------+
+| Node5     | 172.18.1.135       | A4:1F:72:11:B4:B4 |      root   |      calvin |
++-----------+--------------------+-------------------+-------------+-------------+
+| Node6     | 172.18.1.136       | A4:1F:72:11:B4:C1 |      root   |      calvin |
++-----------+--------------------+-------------------+-------------+-------------+
 
 **POD2**
 
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Hostname       | Lights-out address            | MAC              |    Username         | Password            |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Foreman-Jump   | 172.18.1.143                  | A4:1F:72:11:B5:1C|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node7          | 172.18.1.137                  | A4:1F:72:11:B4:CE|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node8          | 172.18.1.138                  | A4:1F:72:11:B4:DB|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node9          | 172.18.1.139                  | A4:1F:72:11:B4:E8|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node11         | 172.18.1.141                  | A4:1F:72:11:B5:02|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node12         | 172.18.1.142                  | A4:1F:72:11:B5:0F|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
++--------------+--------------------+-------------------+-------------+-------------+
+| Hostname     | Lights-out address | MAC               |    Username | Password    |
++--------------+--------------------+-------------------+-------------+-------------+
+| Foreman-Jump | 172.18.1.143       | A4:1F:72:11:B5:1C |      root   |      calvin |
++--------------+--------------------+-------------------+-------------+-------------+
+| Node7        | 172.18.1.137       | A4:1F:72:11:B4:CE |      root   |      calvin |
++--------------+--------------------+-------------------+-------------+-------------+
+| Node8        | 172.18.1.138       | A4:1F:72:11:B4:DB |      root   |      calvin |
++--------------+--------------------+-------------------+-------------+-------------+
+| Node9        | 172.18.1.139       | A4:1F:72:11:B4:E8 |      root   |      calvin |
++--------------+--------------------+-------------------+-------------+-------------+
+| Node11       | 172.18.1.141       | A4:1F:72:11:B5:02 |      root   |      calvin |
++--------------+--------------------+-------------------+-------------+-------------+
+| Node12       | 172.18.1.142       | A4:1F:72:11:B5:0F |      root   |      calvin |
++--------------+--------------------+-------------------+-------------+-------------+
 
 
 Remote access infrastructure
@@ -362,7 +362,8 @@ Dell OPNFV Testlab
 Overview
 ------------------
 
-Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project
+Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal
+servers for the use of OPNFV community as part of the OPNFV Pharos Project
 
 
 The Dell Testlab consists of 3 PODs for the use of the community
@@ -386,69 +387,70 @@ Each of the 2 PODs consists of 6 servers that consist of
 Hardware details
 -----------------
 
-For POD1 and POD2,  the servers  reside within a single Dell PowerEdge 620 chassis and have the following specifications:
+For POD1 and POD2,  the servers  reside within a single Dell PowerEdge 620 chassis and have the
+following specifications:
 
 
 
 **POD1**
 
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Hostname            |  Model               | Memory         | Storage      | Processor           | Socket     |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Jump Server         |  Dell PowerEdge M620 | 64 GB          | 1200GB HDD   | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node2               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node3               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node4               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node5               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node6               |  Dell PowerEdge M620 | 64 GB          | 600GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
++-------------+----------------------+--------+------------+---------------------+--------+
+| Hostname    |  Model               | Memory | Storage    | Processor           | Socket |
++-------------+----------------------+--------+------------+---------------------+--------+
+| Jump Server |  Dell PowerEdge M620 | 64 GB  | 1200GB HDD | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+--------+------------+---------------------+--------+
+| Node2       |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+--------+------------+---------------------+--------+
+| Node3       |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+--------+------------+---------------------+--------+
+| Node4       |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+--------+------------+---------------------+--------+
+| Node5       |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+--------+------------+---------------------+--------+
+| Node6       |  Dell PowerEdge M620 | 64 GB  | 600GB HDD  | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+--------+------------+---------------------+--------+
 
 
 
 
 **POD2**
 
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Hostname            |  Model               |    Memory      | Storage      | Processor           | Socket     |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Jump Server         |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2630 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node7               |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node8               |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node9               |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node11              |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
-| Node12              |  Dell PowerEdge M620 | 64 GB          | 300GB HDD    | Intel  Xeon E5-2640 |   2        |
-+---------------------+----------------------+----------------+--------------+---------------------+------------+
++-------------+----------------------+-----------+-----------+---------------------+--------+
+| Hostname    |  Model               |    Memory | Storage   | Processor           | Socket |
++-------------+----------------------+-----------+-----------+---------------------+--------+
+| Jump Server |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2630 |   2    |
++-------------+----------------------+-----------+-----------+---------------------+--------+
+| Node7       |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+-----------+-----------+---------------------+--------+
+| Node8       |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+-----------+-----------+---------------------+--------+
+| Node9       |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+-----------+-----------+---------------------+--------+
+| Node11      |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+-----------+-----------+---------------------+--------+
+| Node12      |  Dell PowerEdge M620 | 64 GB     | 300GB HDD | Intel  Xeon E5-2640 |   2    |
++-------------+----------------------+-----------+-----------+---------------------+--------+
 
 
 POD3 consists of 6 R630 Rack servers with the following specifications:
 
 **POD3**
 
-+---------------------+----------------------+-----------------+--------------+---------------------+------------+
-| Hostname            |  Model               | Memory          | Storage      | Processor           | Socket     |
-+---------------------+----------------------+-----------------+--------------+---------------------+------------+
-| Jump Server         |  Dell PowerEdge R630 | 128 GB          | 750GB SSD    | Intel  Xeon E5-2698 |   2        |
-+---------------------+----------------------+-----------------+--------------+---------------------+------------+
-| Node2               |  Dell PowerEdge R630 | 128 GB          | 750GB SSD    | Intel  Xeon E5-2698 |   2        |
-+---------------------+----------------------+-----------------+--------------+---------------------+------------+
-| Node3               |  Dell PowerEdge R630 | 128 GB          | 750GB SSD    | Intel  Xeon E5-2698 |   2        |
-+---------------------+----------------------+-----------------+--------------+---------------------+------------+
-| Node4               |  Dell PowerEdge R630 | 128 GB          | 750GB SSD    | Intel  Xeon E5-2698 |   2        |
-+---------------------+----------------------+-----------------+--------------+---------------------+------------+
-| Node5               |  Dell PowerEdge R630 | 128 GB          | 750GB SSD    | Intel  Xeon E5-2698 |   2        |
-+---------------------+----------------------+-----------------+--------------+---------------------+------------+
-| Node6               |  Dell PowerEdge R630 | 128 GB          | 750GB SSD    | Intel  Xeon E5-2698 |   2        |
-+---------------------+----------------------+----------------+---------------+---------------------+------------+
++-------------+----------------------+--------+-----------+---------------------+--------+
+| Hostname    |  Model               | Memory | Storage   | Processor           | Socket |
++-------------+----------------------+--------+-----------+---------------------+--------+
+| Jump Server |  Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel  Xeon E5-2698 |   2    |
++-------------+----------------------+--------+-----------+---------------------+--------+
+| Node2       |  Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel  Xeon E5-2698 |   2    |
++-------------+----------------------+--------+-----------+---------------------+--------+
+| Node3       |  Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel  Xeon E5-2698 |   2    |
++-------------+----------------------+--------+-----------+---------------------+--------+
+| Node4       |  Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel  Xeon E5-2698 |   2    |
++-------------+----------------------+--------+-----------+---------------------+--------+
+| Node5       |  Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel  Xeon E5-2698 |   2    |
++-------------+----------------------+--------+-----------+---------------------+--------+
+| Node6       |  Dell PowerEdge R630 | 128 GB | 750GB SSD | Intel  Xeon E5-2698 |   2    |
++-------------+----------------------+--------+-----------+---------------------+--------+
 
 
 
@@ -485,81 +487,81 @@ Networks
    :alt: POD1-Fuel Overview
    :align: left
 
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Hostname            |  NIC Model                                   | Ports|MAC                | BW    | VLANs/Roles                      |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Jump Server         |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:81 | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:84 | 10G   | Internal Networks (101-106)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:85 | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:87 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:89 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:8B | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node2               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:8E | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:91 | 10G   | Internal Networks (101-106)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:92 | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:94 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:96 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:98 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node3               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:9B | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:9E | 10G   | Internal Networks (101-106)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:9F | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:A1 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:A3 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:A5 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node4               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:A8 | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:AB | 10G   | Internal Networks (101-106)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:AC | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:AE | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:B0 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:B1 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node5               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:B5 | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:B8 | 10G   | Internal Networks (101-106)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:B9 | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:BB | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Broadcom  NetXtreme II BCM57810          | p1p1 | A4:1F:72:11:B4:BD | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:C0 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node6               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:C2 | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:C5 | 10G   | Internal Networks (101-106)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:C6 | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:C8 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Broadcom  NetXtreme II BCM57810          | p1p1 | A4:1F:72:11:B4:CA | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:CD | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+| Hostname    |  NIC Model                          | Ports | MAC               | BW  | VLANs/Roles                 |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+| Jump Server |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:81 | 10G | PXE                         |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | em2   | A4:1F:72:11:B4:84 | 10G | Internal Networks (101-106) |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:85 | 1G  | Public                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p3p2  | A4:1F:72:11:B4:87 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  3, Intel  82599                    | p1p1  | A4:1F:72:11:B4:89 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p1p2  | A4:1F:72:11:B4:8B | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node2       |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:8E | 10G | PXE                         |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | em2   | A4:1F:72:11:B4:91 | 10G | Internal Networks (101-106) |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:92 | 1G  | Public                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p3p2  | A4:1F:72:11:B4:94 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  3, Intel  82599                    | p1p1  | A4:1F:72:11:B4:96 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p1p2  | A4:1F:72:11:B4:98 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node3       |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:9B | 10G | PXE                         |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | em2   | A4:1F:72:11:B4:9E | 10G | Internal Networks (101-106) |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:9F | 1G  | Public                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p3p2  | A4:1F:72:11:B4:A1 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  3, Intel  82599                    | p1p1  | A4:1F:72:11:B4:A3 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p1p2  | A4:1F:72:11:B4:A5 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node4       |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:A8 | 10G | PXE                         |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | em2   | A4:1F:72:11:B4:AB | 10G | Internal Networks (101-106) |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:AC | 1G  | Public                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p3p2  | A4:1F:72:11:B4:AE | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  3, Intel  82599                    | p1p1  | A4:1F:72:11:B4:B0 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p1p2  | A4:1F:72:11:B4:B1 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node5       |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:B5 | 10G | PXE                         |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | em2   | A4:1F:72:11:B4:B8 | 10G | Internal Networks (101-106) |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:B9 | 1G  | Public                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p3p2  | A4:1F:72:11:B4:BB | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  3, Broadcom  NetXtreme II BCM57810 | p1p1  | A4:1F:72:11:B4:BD | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p1p2  | A4:1F:72:11:B4:C0 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node6       |  1, Broadcom  NetXtreme II BCM57810 | em1   | A4:1F:72:11:B4:C2 | 10G | PXE                         |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | em2   | A4:1F:72:11:B4:C5 | 10G | Internal Networks (101-106) |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  2, Intel  82599                    | p3p1  | A4:1F:72:11:B4:C6 | 1G  | Public                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p3p2  | A4:1F:72:11:B4:C8 | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |  3, Broadcom  NetXtreme II BCM57810 | p1p1  | A4:1F:72:11:B4:CA | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
+|             |                                     | p1p2  | A4:1F:72:11:B4:CD | 10G | Unused                      |
++-------------+-------------------------------------+-------+-------------------+-----+-----------------------------+
 
 
 
@@ -572,81 +574,81 @@ Networks
    :align: left
 
 
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Hostname            |  NIC Model                                   | Ports|MAC                | BW    | Roles                            |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Foreman Jump        |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B5:1D | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B5:20 | 10G   | Internal Networks (201-205)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B5:21 | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B5:23 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, TBD                                      | p1p1 | A4:1F:72:11:B4:89 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:8B | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node7               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:CF | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:D2 | 10G   | Internal Networks (201-205)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:D3 | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:D5 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3,  Broadcom  NetXtreme II BCM57810         | p1p1 | A4:1F:72:11:B4:D7 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:DA | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node8               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:DC | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:DF | 10G   | Internal Networks (201-205)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:E0 | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:E2 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Broadcom  NetXtreme II BCM57810          | p1p1 | A4:1F:72:11:B4:E4 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:E7 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node9               |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B4:E9 | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B4:EC | 10G   | Internal Networks (201-205)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B4:ED | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B4:EF | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B4:F1 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:F3 | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node11              |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B5:03 | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B5:06 | 10G   | Internal Networks (201-205)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B5:07 | 10G   | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B5:09 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, Intel  82599                             | p1p1 | A4:1F:72:11:B5:0B | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B5:0D | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Node12              |  1, Broadcom  NetXtreme II BCM57810          | em1  | A4:1F:72:11:B5:10 | 10G   | PXE                              |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | em2  | A4:1F:72:11:B5:13 | 10G   | Internal Networks (201-205)      |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  2, Intel  82599                             | p3p1 | A4:1F:72:11:B5:14 | 1G    | Public                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p3p2 | A4:1F:72:11:B5:16 | 10G   | Unused                           |
-|                     +----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |  3, TBD                                      | p1p1 | A4:1F:72:11:B4:89 | 10G   | Unused                           |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              | p1p2 | A4:1F:72:11:B4:8B | 10G   | Unused                           |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+| Hostname     |  NIC Model                           | Ports | MAC               | BW  | Roles                       |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+| Foreman Jump |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B5:1D | 10G | PXE                         |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | em2   | A4:1F:72:11:B5:20 | 10G | Internal Networks (201-205) |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B5:21 | 1G  | Public                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B5:23 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  3, TBD                              | p1p1  | A4:1F:72:11:B4:89 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:8B | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node7        |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B4:CF | 10G | PXE                         |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | em2   | A4:1F:72:11:B4:D2 | 10G | Internal Networks (201-205) |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B4:D3 | 1G  | Public                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B4:D5 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  3,  Broadcom  NetXtreme II BCM57810 | p1p1  | A4:1F:72:11:B4:D7 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:DA | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node8        |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B4:DC | 10G | PXE                         |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | em2   | A4:1F:72:11:B4:DF | 10G | Internal Networks (201-205) |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B4:E0 | 1G  | Public                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B4:E2 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  3, Broadcom  NetXtreme II BCM57810  | p1p1  | A4:1F:72:11:B4:E4 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:E7 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node9        |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B4:E9 | 10G | PXE                         |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | em2   | A4:1F:72:11:B4:EC | 10G | Internal Networks (201-205) |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B4:ED | 1G  | Public                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B4:EF | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  3, Intel  82599                     | p1p1  | A4:1F:72:11:B4:F1 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:F3 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node11       |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B5:03 | 10G | PXE                         |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | em2   | A4:1F:72:11:B5:06 | 10G | Internal Networks (201-205) |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B5:07 | 10G | Public                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B5:09 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  3, Intel  82599                     | p1p1  | A4:1F:72:11:B5:0B | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B5:0D | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+| Node12       |  1, Broadcom  NetXtreme II BCM57810  | em1   | A4:1F:72:11:B5:10 | 10G | PXE                         |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | em2   | A4:1F:72:11:B5:13 | 10G | Internal Networks (201-205) |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  2, Intel  82599                     | p3p1  | A4:1F:72:11:B5:14 | 1G  | Public                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p3p2  | A4:1F:72:11:B5:16 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |  3, TBD                              | p1p1  | A4:1F:72:11:B4:89 | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
+|              |                                      | p1p2  | A4:1F:72:11:B4:8B | 10G | Unused                      |
++--------------+--------------------------------------+-------+-------------------+-----+-----------------------------+
 
 
 
@@ -663,155 +665,155 @@ Networks
 
 
 
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Hostname            |  NIC Model                                   | Ports|MAC                | BW    |  Roles (VLANs)                   |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-| Jump Server         |  1, Intel 2P X520/2P I350 rNDC               | em1  | EC:F4:BB:D7:14:20 | 1G    | PXE                              |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | em2  | EC:F4:BB:D7:14:22 | 10G   | Internal Networks (201,202,203)  |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | p3p1 | EC:F4:BB:D7:14:24 | 1G    | Public                           |
-|                     |                                              |      |                   |       |                                  |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-| Node1               |  1, Intel 2P X520/2P I350 rNDC               | em1  | EC:F4:BB:D6:F2:98 | 10G   | PXE                              |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | em2  | EC:F4:BB:D6:F2:9A | 10G   | Internal Networks  (201,202,203) |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | p3p1 | EC:F4:BB:D6:F2:9C | 1G    | Public                           |
-|                     |                                              |      |                   |       |                                  |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-| Node2               |  1, Intel 2P X520/2P I350 rNDC               | em1  | EC:F4:BB:D6:F9:10 | 1G    | PXE                              |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | em2  | EC:F4:BB:D6:F9:12 | 10G   | Internal Networks (201,202,203)  |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | p3p1 | EC:F4:BB:D6:F9:14 | 1G    | Public                           |
-|                     |                                              |      |                   |       |                                  |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-| Node3               |  1, Intel 2P X520/2P I350 rNDC               | em1  | EC:F4:BB:D7:C9:B8 | 1G    | PXE                              |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | em2  | EC:F4:BB:D7:C9:BA | 10G   | Internal Networks (201,202,203)  |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | p3p1 | EC:F4:BB:D7:C9:BC | 1G    | Public                           |
-|                     |                                              |      |                   |       |                                  |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-| Node4               |  1, Intel 2P X520/2P I350 rNDC               | em1  | EC:F4:BB:D7:16:E8 | 10G   | PXE                              |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | em2  | EC:F4:BB:D7:16:EA | 10G   | Internal Networks (201,202,203)  |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | p3p1 | EC:F4:BB:D7:16:EA | 1G    | Public                           |
-|                     |                                              |      |                   |       |                                  |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-| Node5               |  1, Intel 2P X520/2P I350 rNDC               | em1  | EC:F4:BB:D6:FE:98 | 1G    | Unused                           |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | em2  | EC:F4:BB:D6:FE:9A | 10G   | Internal Networks (201,202,203)  |
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              +------+-------------------+-------+----------------------------------+
-|                     |                                              |      |                   |       |                                  |
-|                     |                                              | p3p1 | EC:F4:BB:D6:FE:9C | 1G    | Public                           |
-|                     |                                              |      |                   |       |                                  |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+| Hostname    |  NIC Model                     | Ports | MAC               | BW  |  Roles (VLANs)                   |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+| Jump Server |  1, Intel 2P X520/2P I350 rNDC | em1   | EC:F4:BB:D7:14:20 | 1G  | PXE                              |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | em2   | EC:F4:BB:D7:14:22 | 10G | Internal Networks (201,202,203)  |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | p3p1  | EC:F4:BB:D7:14:24 | 1G  | Public                           |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+| Node1       |  1, Intel 2P X520/2P I350 rNDC | em1   | EC:F4:BB:D6:F2:98 | 10G | PXE                              |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | em2   | EC:F4:BB:D6:F2:9A | 10G | Internal Networks  (201,202,203) |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | p3p1  | EC:F4:BB:D6:F2:9C | 1G  | Public                           |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+| Node2       |  1, Intel 2P X520/2P I350 rNDC | em1   | EC:F4:BB:D6:F9:10 | 1G  | PXE                              |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | em2   | EC:F4:BB:D6:F9:12 | 10G | Internal Networks (201,202,203)  |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | p3p1  | EC:F4:BB:D6:F9:14 | 1G  | Public                           |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+| Node3       |  1, Intel 2P X520/2P I350 rNDC | em1   | EC:F4:BB:D7:C9:B8 | 1G  | PXE                              |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | em2   | EC:F4:BB:D7:C9:BA | 10G | Internal Networks (201,202,203)  |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | p3p1  | EC:F4:BB:D7:C9:BC | 1G  | Public                           |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+| Node4       |  1, Intel 2P X520/2P I350 rNDC | em1   | EC:F4:BB:D7:16:E8 | 10G | PXE                              |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | em2   | EC:F4:BB:D7:16:EA | 10G | Internal Networks (201,202,203)  |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | p3p1  | EC:F4:BB:D7:16:EA | 1G  | Public                           |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+| Node5       |  1, Intel 2P X520/2P I350 rNDC | em1   | EC:F4:BB:D6:FE:98 | 1G  | Unused                           |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | em2   | EC:F4:BB:D6:FE:9A | 10G | Internal Networks (201,202,203)  |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
+|             |                                |       |                   |     |                                  |
+|             |                                | p3p1  | EC:F4:BB:D6:FE:9C | 1G  | Public                           |
+|             |                                |       |                   |     |                                  |
++-------------+--------------------------------+-------+-------------------+-----+----------------------------------+
 
 
 **Subnet allocations**
 
-+-------------------+----------------+-------------------+---------------+----------+
-| Network name      | Address        | Mask              | Gateway       | VLAN id  |
-+-------------------+----------------+-------------------+---------------+----------+
-| POD1 Public       | 172.18.0.64    |  255.255.255.192  | 172.18.0.65   | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| POD2 Public       | 172.18.0.0     |  255.255.255.192  | 172.18.0.1    | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| POD3 Public       | 172.18.1.0     |  255.255.255.0    | 172.18.1.1    | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Lights Out        | 172.18.0.128   |  255.255.255.128  | 172.18.0.129  | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
++--------------+--------------+------------------+--------------+----------+
+| Network name | Address      | Mask             | Gateway      | VLAN id  |
++--------------+--------------+------------------+--------------+----------+
+| POD1 Public  | 172.18.0.64  |  255.255.255.192 | 172.18.0.65  | Untagged |
++--------------+--------------+------------------+--------------+----------+
+| POD2 Public  | 172.18.0.0   |  255.255.255.192 | 172.18.0.1   | Untagged |
++--------------+--------------+------------------+--------------+----------+
+| POD3 Public  | 172.18.1.0   |  255.255.255.0   | 172.18.1.1   | Untagged |
++--------------+--------------+------------------+--------------+----------+
+| Lights Out   | 172.18.0.128 |  255.255.255.128 | 172.18.0.129 | Untagged |
++--------------+--------------+------------------+--------------+----------+
 
 
 **Lights out Network**
 
 **POD1**
 
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Hostname       | Lights-out address            | MAC              |    Username         | Password            |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Jump           | 172.18.0.131                  | A4:1F:72:11:B4:80|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node2          | 172.18.0.132                  | A4:1F:72:11:B4:8D|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node3          | 172.18.0.133                  | A4:1F:72:11:B4:9A|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node4          | 172.18.0.134                  | A4:1F:72:11:B4:A7|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node5          | 172.18.0.135                  | A4:1F:72:11:B4:B4|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node6          | 172.18.0.136                  | A4:1F:72:11:B4:C1|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
++----------+--------------------+-------------------+-------------+-------------+
+| Hostname | Lights-out address | MAC               |    Username | Password    |
++----------+--------------------+-------------------+-------------+-------------+
+| Jump     | 172.18.0.131       | A4:1F:72:11:B4:80 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node2    | 172.18.0.132       | A4:1F:72:11:B4:8D |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node3    | 172.18.0.133       | A4:1F:72:11:B4:9A |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node4    | 172.18.0.134       | A4:1F:72:11:B4:A7 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node5    | 172.18.0.135       | A4:1F:72:11:B4:B4 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node6    | 172.18.0.136       | A4:1F:72:11:B4:C1 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
 
 **POD2**
 
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Hostname       | Lights-out address            | MAC              |    Username         | Password            |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Jump           | 172.18.0.143                  | A4:1F:72:11:B5:1C|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node7          | 172.18.0.137                  | A4:1F:72:11:B4:CE|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node8          | 172.18.0.138                  | A4:1F:72:11:B4:DB|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node9          | 172.18.0.139                  | A4:1F:72:11:B4:E8|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node11         | 172.18.0.141                  | A4:1F:72:11:B5:02|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node12         | 172.18.0.142                  | A4:1F:72:11:B5:0F|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
++----------+--------------------+-------------------+-------------+-------------+
+| Hostname | Lights-out address | MAC               |    Username | Password    |
++----------+--------------------+-------------------+-------------+-------------+
+| Jump     | 172.18.0.143       | A4:1F:72:11:B5:1C |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node7    | 172.18.0.137       | A4:1F:72:11:B4:CE |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node8    | 172.18.0.138       | A4:1F:72:11:B4:DB |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node9    | 172.18.0.139       | A4:1F:72:11:B4:E8 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node11   | 172.18.0.141       | A4:1F:72:11:B5:02 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node12   | 172.18.0.142       | A4:1F:72:11:B5:0F |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
 
 
 
 **POD3**
 
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Hostname       | Lights-out address            | MAC              |    Username         | Password            |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Jump           | 172.18.0.181                  | 74:E6:E2:FA:BB:D8|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node1          | 172.18.0.182                  | 74:E6:E2:FA:E9:2E|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node2          | 172.18.0.183                  | 74:E6:E2:FA:FC:E2|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node3          | 172.18.0.184                  | 74:E6:E2:FB:05:68|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node4          | 172.18.0.185                  | 74:E6:E2:FA:A4:02|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Node5          | 172.18.0.186                  | 74:E6:E2:FA:E4:18|      root           |      calvin         |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
++----------+--------------------+-------------------+-------------+-------------+
+| Hostname | Lights-out address | MAC               |    Username | Password    |
++----------+--------------------+-------------------+-------------+-------------+
+| Jump     | 172.18.0.181       | 74:E6:E2:FA:BB:D8 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node1    | 172.18.0.182       | 74:E6:E2:FA:E9:2E |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node2    | 172.18.0.183       | 74:E6:E2:FA:FC:E2 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node3    | 172.18.0.184       | 74:E6:E2:FB:05:68 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node4    | 172.18.0.185       | 74:E6:E2:FA:A4:02 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
+| Node5    | 172.18.0.186       | 74:E6:E2:FA:E4:18 |      root   |      calvin |
++----------+--------------------+-------------------+-------------+-------------+
 
 
 Remote access infrastructure
@@ -821,7 +823,8 @@ The Dell OPNFV testlab is free to use for the OPNFV community.
 
 A VPN is used to provide access to the Dell Testlab.
 
-To access the Testlab, please visit the Dell OPNFV Lab's wiki page (https://wiki.opnfv.org/dell_hosting) for details.
+To access the Testlab, please visit the Dell OPNFV Lab's wiki page
+(https://wiki.opnfv.org/dell_hosting) for details.
 
 
 *Accessing the Teslab*