[docs] Documentation for BNG PPPoE RFC2544 test cases
[yardstick.git] / docs / testing / user / userguide / opnfv_yardstick_tc092.rst
1 .. This work is licensed under a Creative Commons Attribution 4.0 International
2 .. License.
3 .. http://creativecommons.org/licenses/by/4.0
4 .. (c) OPNFV, Ericsson and others.
5
6 *************************************
7 Yardstick Test Case Description TC092
8 *************************************
9
10 +-----------------------------------------------------------------------------+
11 |SDN Controller resilience in HA configuration                                |
12 |                                                                             |
13 +--------------+--------------------------------------------------------------+
14 |test case id  | OPNFV_YARDSTICK_TC092: SDN controller resilience and high    |
15 |              | availability HA configuration                                |
16 |              |                                                              |
17 +--------------+--------------------------------------------------------------+
18 |test purpose  | This test validates SDN controller node high availability by |
19 |              | verifying there is no impact on the data plane connectivity  |
20 |              | when one SDN controller fails in a HA configuration,         |
21 |              | i.e. all existing configured network services DHCP, ARP, L2, |
22 |              | L3VPN, Security Groups should continue to operate            |
23 |              | between the existing VMs while one SDN controller instance   |
24 |              | is offline and rebooting.                                    |
25 |              |                                                              |
26 |              | The test also validates that network service operations such |
27 |              | as creating a new VM in an existing or new L2 network        |
28 |              | network remain operational while one instance of the         |
29 |              | SDN controller is offline and recovers from the failure.     |
30 |              |                                                              |
31 +--------------+--------------------------------------------------------------+
32 |test method   | This test case:                                              |
33 |              |  1. fails one instance of a SDN controller cluster running   |
34 |              |     in a HA configuration on the OpenStack controller node   |
35 |              |                                                              |
36 |              |  2. checks if already configured L2 connectivity between     |
37 |              |     existing VMs is not impacted                             |
38 |              |                                                              |
39 |              |  3. verifies that the system never loses the ability to      |
40 |              |     execute virtual network operations, even when the        |
41 |              |     failed SDN Controller is still recovering                |
42 |              |                                                              |
43 +--------------+--------------------------------------------------------------+
44 |attackers     | In this test case, an attacker called “kill-process” is      |
45 |              | needed. This attacker includes three parameters:             |
46 |              |                                                              |
47 |              |  1. ``fault_type``: which is used for finding the attacker's |
48 |              |     scripts. It should be set to 'kill-process' in this test |
49 |              |                                                              |
50 |              |  2. ``process_name``: should be set to sdn controller        |
51 |              |     process                                                  |
52 |              |                                                              |
53 |              |  3. ``host``: which is the name of a control node where      |
54 |              |     opendaylight process is running                          |
55 |              |                                                              |
56 |              | example:                                                     |
57 |              |   - ``fault_type``: “kill-process”                           |
58 |              |   - ``process_name``: “opendaylight-karaf” (TBD)             |
59 |              |   - ``host``: node1                                          |
60 |              |                                                              |
61 +--------------+--------------------------------------------------------------+
62 |monitors      | In this test case, the following monitors are needed         |
63 |              |  1. ``ping_same_network_l2``: monitor pinging traffic        |
64 |              |     between the VMs in same neutron network                  |
65 |              |                                                              |
66 |              |  2. ``ping_external_snat``: monitor ping traffic from VMs to |
67 |              |     external destinations (e.g. google.com)                  |
68 |              |                                                              |
69 |              |  3. ``SDN controller process monitor``: a monitor checking   |
70 |              |     the state of a specified SDN controller process. It      |
71 |              |     measures the recovery time of the given process.         |
72 |              |                                                              |
73 +--------------+--------------------------------------------------------------+
74 |operations    | In this test case, the following operations are needed:      |
75 |              |  1. "nova-create-instance-in_network": create a VM instance  |
76 |              |     in one of the existing neutron network.                  |
77 |              |                                                              |
78 +--------------+--------------------------------------------------------------+
79 |metrics       | In this test case, there are two metrics:                    |
80 |              |  1. process_recover_time: which indicates the maximun        |
81 |              |     time (seconds) from the process being killed to          |
82 |              |     recovered                                                |
83 |              |                                                              |
84 |              |  2. packet_drop: measure the packets that have been dropped  |
85 |              |     by the monitors using pktgen.                            |
86 |              |                                                              |
87 +--------------+--------------------------------------------------------------+
88 |test tool     | Developed by the project. Please see folder:                 |
89 |              | "yardstick/benchmark/scenarios/availability/ha_tools"        |
90 |              |                                                              |
91 +--------------+--------------------------------------------------------------+
92 |references    | TBD                                                          |
93 |              |                                                              |
94 +--------------+--------------------------------------------------------------+
95 |configuration | This test case needs two configuration files:                |
96 |              | 1. test case file: opnfv_yardstick_tc092.yaml                |
97 |              |                                                              |
98 |              |    - Attackers: see above “attackers” discription            |
99 |              |    - Monitors: see above “monitors” discription              |
100 |              |                                                              |
101 |              |      - waiting_time: which is the time (seconds) from the    |
102 |              |        process being killed to stoping monitors the          |
103 |              |        monitors                                              |
104 |              |                                                              |
105 |              |    - SLA: see above “metrics” discription                    |
106 |              |                                                              |
107 |              | 2. POD file: pod.yaml The POD configuration should record    |
108 |              |    on pod.yaml first. the “host” item in this test case      |
109 |              |    will use the node name in the pod.yaml.                   |
110 |              |                                                              |
111 +--------------+--------------------------------------------------------------+
112 |test sequence | Description and expected result                              |
113 |              |                                                              |
114 +--------------+--------------------------------------------------------------+
115 |pre-action    |  1. The OpenStack cluster is set up with an SDN controller   |
116 |              |     running in a three node cluster configuration.           |
117 |              |                                                              |
118 |              |  2. One or more neutron networks are created with two or     |
119 |              |     more VMs attached to each of the neutron networks.       |
120 |              |                                                              |
121 |              |  3. The neutron networks are attached to a neutron router    |
122 |              |     which is attached to an external network the towards     |
123 |              |     DCGW.                                                    |
124 |              |                                                              |
125 |              |  4. The master node of SDN controller cluster is known.      |
126 |              |                                                              |
127 +--------------+--------------------------------------------------------------+
128 |step 1        | Start ip connectivity monitors:                              |
129 |              |  1. Check the L2 connectivity between the VMs in the same    |
130 |              |     neutron network.                                         |
131 |              |                                                              |
132 |              |  2. Check the external connectivity of the VMs.              |
133 |              |                                                              |
134 |              | Each monitor runs in an independent process.                 |
135 |              |                                                              |
136 |              | Result: The monitor info will be collected.                  |
137 |              |                                                              |
138 +--------------+--------------------------------------------------------------+
139 |step 2        | Start attacker:                                              |
140 |              | SSH to the VIM node and kill the SDN controller process      |
141 |              | determined in step 2.                                        |
142 |              |                                                              |
143 |              | Result: One SDN controller service will be shut down         |
144 |              |                                                              |
145 +--------------+--------------------------------------------------------------+
146 |step 3        | Restart the SDN controller.                                  |
147 |              |                                                              |
148 +--------------+--------------------------------------------------------------+
149 |step 4        | Create a new VM in the existing Neutron network while the    |
150 |              | SDN controller is offline or still recovering.               |
151 |              |                                                              |
152 +--------------+--------------------------------------------------------------+
153 |step 5        | Stop IP connectivity monitors after a period of time         |
154 |              | specified by “waiting_time”                                  |
155 |              |                                                              |
156 |              | Result: The monitor info will be aggregated                  |
157 |              |                                                              |
158 +--------------+--------------------------------------------------------------+
159 |step 6        | Verify the IP connectivity monitor result                    |
160 |              |                                                              |
161 |              | Result: IP connectivity monitor should not have any packet   |
162 |              | drop failures reported                                       |
163 |              |                                                              |
164 +--------------+--------------------------------------------------------------+
165 |step 7        | Verify process_recover_time, which indicates the maximun     |
166 |              | time (seconds) from the process being killed to recovered,   |
167 |              | is within the SLA. This step blocks until either the         |
168 |              | process has recovered or a timeout occurred.                 |
169 |              |                                                              |
170 |              | Result: process_recover_time is within SLA limits, if not,   |
171 |              | test case failed and stopped.                                |
172 |              |                                                              |
173 +--------------+--------------------------------------------------------------+
174 |step 8        | Start IP connectivity monitors for the  new VM:              |
175 |              |                                                              |
176 |              | 1. Check the L2 connectivity from the existing VMs to the    |
177 |              |    new VM in the Neutron network.                            |
178 |              |                                                              |
179 |              | 2. Check connectivity from one VM to an external host on     |
180 |              |    the Internet to verify SNAT functionality.                |
181 |              |                                                              |
182 |              | Result: The monitor info will be collected.                  |
183 |              |                                                              |
184 +--------------+--------------------------------------------------------------+
185 |step 9        | Stop IP connectivity monitors after a period of time         |
186 |              | specified by “waiting_time”                                  |
187 |              |                                                              |
188 |              | Result: The monitor info will be aggregated                  |
189 |              |                                                              |
190 +--------------+--------------------------------------------------------------+
191 |step 10       | Verify the IP connectivity monitor result                    |
192 |              |                                                              |
193 |              | Result: IP connectivity monitor should not have any packet   |
194 |              | drop failures reported                                       |
195 |              |                                                              |
196 +--------------+--------------------------------------------------------------+
197 |test verdict  | Fails only if SLA is not passed, or if there is a test case  |
198 |              | execution problem.                                           |
199 |              |                                                              |